It's highly recommended.

If you have two appliances that consume 1100 watts each, like a microwave and a coffee machine, that's already 20 amps right there (assuming North American voltage).

Don't forget to use outlets with ground fault circuit interrupters (GFCI) near any area that may get wet.

<<>>

Kitchen counters use a three wire split receptacle. The common tie bar on the hot side of the receptacle is removed. The red wire is connected to the top terminal and the black wire of the three wire cable it connected to the bottom terminal of the receptacle. The white wire is connected as in all receptacles to the silver coloured screws on the receptacle. The bare copper ground wire connects to the green ground screw This gives you a full 15 amps on the top half of the receptacle and a full 15 amps on the bottom of the receptacle. This is a dedicated circuit that goes directly back to the distribution panel. These types of outlet are spaced at six foot intervals along the entire kitchen counter.

User Avatar

Wiki User

11y ago

What else can I help you with?

Continue Learning about Natural Sciences

Why are kitchens and bathrooms required to be on separate 20-amp receptacle branch circuits?

The NEC doesn't provide justifications for its requirements, but the likely reason is simply the amount of amps often drawn in kitchens and bathrooms because of all the appliances specific to these locations. NEC 210.11 requires a minimum of two 20 amp circuits for counter top receptacles in the kitchen, called Small Appliance Branch Circuits. It is my understand of the code that these small appliance circuits in the kitchen can also cover the dinning room, and similar areas in a dwelling, and while most electricians seem to frown on this, one of these circuits can be used for the refrigerator receptacle. One can also supply receptacles for any electrical stuff on gas-fired ranges. Dishwashers and waste disposals are not plugged in on counter tops so presumably need to be supplied by (a) circuit(s) other than these. On counter tops in the kitchen all receptacles must be GFCI protected. The bathroom circuit is intended to either a) serve a GFCI receptacle at the sink and can also serve another such receptacle in another bathroom, but in this case cannot serve other loads in the bathroom, or b) can serve the receptacle and other permissible loads in the same bathroom but no loads outside of it. Answer In real life, our kitchen circuit also serves the dining room. Because we did not increase the capability of the circuit when we added the microwave, the dining room light dims out when we use the microwave. There would be similar issues with kitchen and bathrooms sharing one circuit. It is funny how real life so often is "out-of-code". Following the current code, the lights in the dinning room would not dim because the two-small appliance circuit described above is only intended to serve receptacles in the kitchen and dinning room, and similar spaces in a dwelling, and so putting lights (any lights that are not lamps plugged into to wall receptacles) on them would not be permitted. In other words, your lights and your receptacles should not be on the same circuit, according to the NEC


Do you need a 20 amp circuit for microwave?

That depends on the amount of current that the microwave draws. Calculate the current draw of the microwave, then do not use more than 80% of the circuit breaker that you put in circuit. More information: In the United States, kitchen counter top receptacles are required to be fed from at least 2 - 20 amp "small appliance" circuits. You may have more and I know of no requirement that additional circuits must be 20 amps. With this in mind, consider what Redbeard has answered. However, in my experience the term "small appliance circuit" is usually ASSUMED to be 20 amps because very rarely are more than the 2 required circuits installed. Your inspecting jurisdiction may make this assumption. They are the final arbiter of what the code means.


Can you use a 14 romax for receptacle?

No, it is not recommended to use a 14-gauge Romex cable for receptacles. A 14-gauge wire is typically used for lighting circuits, while a 12-gauge wire is usually used for receptacles to handle the higher current requirements. It is important to match the wire size with the intended usage for safety and code compliance.


Do you have to pin breakers together when sharing the neutral on branch circuits?

Pinning breakers is becoming a thing of the past. This is due to the manufacturing of two pole breakers with one common trip reset handle. The electrical code states that on a 240 volt breaker if one leg trips the other leg must be disconnected from the supply also. This is a safety factor so that if they weren't tied together and one leg tripped the other half of the breaker would remain "hot". Any one working on that circuit in the tripped position could get a nasty shock from the un-tripped leg. Pinning the breakers on 240 volts was done because it was convenient to use single pole breakers in the distribution panel. To abide by the code the two single pole breakers were common tied together. When the branch circuits share a neutral to a common box they have to be common tied for the same reason above. This type of circuit is found on kitchen counter receptacles. Two separate circuits that share a neutral and go to separate junction boxes do not need the breakers tied.


What materials do you need for which banana rots faster in the fridge or counter?

Materials needed: ripe bananas, a refrigerator, a kitchen counter, and a timer. To conduct the experiment, place one banana on the counter and one in the fridge, ensuring that they are both exposed to similar environmental conditions except for temperature. Record observations of each banana's condition over several days to determine which one rots faster.

Related Questions

Why are kitchens and bathrooms required to be on separate 20-amp receptacle branch circuits?

The NEC doesn't provide justifications for its requirements, but the likely reason is simply the amount of amps often drawn in kitchens and bathrooms because of all the appliances specific to these locations. NEC 210.11 requires a minimum of two 20 amp circuits for counter top receptacles in the kitchen, called Small Appliance Branch Circuits. It is my understand of the code that these small appliance circuits in the kitchen can also cover the dinning room, and similar areas in a dwelling, and while most electricians seem to frown on this, one of these circuits can be used for the refrigerator receptacle. One can also supply receptacles for any electrical stuff on gas-fired ranges. Dishwashers and waste disposals are not plugged in on counter tops so presumably need to be supplied by (a) circuit(s) other than these. On counter tops in the kitchen all receptacles must be GFCI protected. The bathroom circuit is intended to either a) serve a GFCI receptacle at the sink and can also serve another such receptacle in another bathroom, but in this case cannot serve other loads in the bathroom, or b) can serve the receptacle and other permissible loads in the same bathroom but no loads outside of it. Answer In real life, our kitchen circuit also serves the dining room. Because we did not increase the capability of the circuit when we added the microwave, the dining room light dims out when we use the microwave. There would be similar issues with kitchen and bathrooms sharing one circuit. It is funny how real life so often is "out-of-code". Following the current code, the lights in the dinning room would not dim because the two-small appliance circuit described above is only intended to serve receptacles in the kitchen and dinning room, and similar spaces in a dwelling, and so putting lights (any lights that are not lamps plugged into to wall receptacles) on them would not be permitted. In other words, your lights and your receptacles should not be on the same circuit, according to the NEC


Should I put in an island counter or a peninsula counter when I renovate my kitchen?

You need to study the circulation pattern of your kitchen to make that choice. Do you need or want people to circulate through the kitchen. A peninsula will limit the circulation through the kitchen. There is something nice about not having traffic in a kitchen when working. If your kitchen is big enough it may accommodate both.


What makes the kitchen counter chairs at Furniture Decor stand out from the rest?

At Furniture Decor, our kitchen counter chairs are crafted with a perfect blend of style, comfort, and durability. Whether you need a high chair for your kitchen counter, elegant wood kitchen counter chairs, or the best kitchen counter chairs for sale, we have a wide range of options to suit your needs. Each chair is made from premium materials and designed to complement your kitchen’s aesthetic, offering both functionality and a touch of sophistication. Visit Furniture Decor in South Africa to find the perfect kitchen counter chairs that will enhance your home’s decor and provide lasting comfort. +27810467689


What receptacles will except a 15 amp attachment plug?

Many receptacles will. First you need to tell us if you are in north America, UK or Australia.


What are the benefits of installing an under counter hot water heater in a kitchen?

Installing an under counter hot water heater in a kitchen provides instant hot water, saves energy by reducing water waste, and frees up space by eliminating the need for a large water heater.


How to figure sq. ft. for kitchen counter-top?

To calculate square footage you need to multiply the length by the width. L x W = Sq.Ft.


What equipment do you need to cut a kitchen counter top?

I usually use a circular saw to size up the length and a jigsaw to cut out the basin sink cut-out.


What are the best prices on waste receptacles?

The price will depend on whether or not you need it for commercial or personal use. Commercial receptacles normally range anywhere from $80.00 to $500.00. Personal receptables will be less.


What size circuit breaker do you need for kichen counter outlets?

Two 20 Amp circuits with the outlets staggered so a different circuit is on two adjacent outlets. Should be GFCI protected.


How much to install kitchen counter top?

Need more info... Material type,style specs


Why do you need circuits?

i dont know why is it


What are some good quality outdoor garbage cans?

Rubbermaid makes a wide variety of garbage containers that you can use, they are study enough for outdoor use and also reasonably priced if it happens to blow away again.Mistral is also a decent brand, if a little less well known.