No houses are wired for 440 volts. In the USA, most houses are wired for 240/120 volts called single or split phase. That means each "leg" of the service is 120 volts to ground, but across the two it sums to 240 volts, since each "leg" is 180 degrees out of phase with respect to each other. When one "leg" of the service is at +120 volts, the other "leg" is its mirror image, at -120 volts. In this way, connecting across the two yields twice the voltage of either leg to ground, allowing the use of 240 volt or 120 volt appliances depending on how connected- to ground or across "legs". Most other countries with 220-240 volt appliances do not use split phase service. There is only the one phase to ground and in those countries the incoming line is 220-240 volts to ground, voltage depending on the country.

User Avatar

Wiki User

16y ago

What else can I help you with?

Continue Learning about Natural Sciences

In a 440 volt and 220 volt or 100 volt feeder panel what do you call a component that monitor the wiring condition of the feeder?

Grounding monitor


How to convert 440 VOLTS to 380 VOLTS?

You can use a transformer to step down the voltage from 440 volts to 380 volts. Make sure to use a transformer that is rated for the required input and output voltage, and have a qualified electrician perform the installation for safety.


Why is it stated - 3 phase 440 VAC when one phase voltage is 220 VAC?

In three-phase there are three live wires and a neutral. The voltage of a three-phase system is always quoted as the live-to-live voltage, and the voltage from one live wire to neutral is 57.7% of that. A 440 v 3-ph system has 254 volts between live and neutral. <<>> The question statement is not correct. Two legs from a three phase three wire 440 volt system will still be 440 but classed a single phase. On a three phase four wire system supply, the voltages will be determined by the following equation. 440/(square root of 3) 1.73 = 254 volts. The second single phase voltage attainable from this source connection is any one of the three phase legs to grounded neutral center point. This is known as a wye or star point connected voltage supply. To obtain a 220 volt single phase voltage, the three phase system would have to have a voltage of 220 x 1.73 = 380 volts.


Can you use 265 volt appliance on a 220 volt line?

Using a 265-volt appliance on a 220-volt line can be risky and may damage the appliance, cause a short circuit, or result in a safety hazard. It is recommended to use voltage converters or transformers to ensure safe operation of the appliance.


How deep do you bury 110 volt romex electrical line?

please tell your line voltage (like 230V,400KV,)!

Related Questions

Why 3 phase line 440 volt instead of 660volts?

common phase


What is the total resistance of a parallel circuit with branch voltages of 440 volt and 440 volt and branch currents of 4 amp and 16 amp?

resistance = volt / current . 440 volt across a parallel circuit means the same 440 volt across both resistance s. hence resistance r = volt / current . 440 / 20 amp = 27.5 ohms total resistance


Can a 440 volt capacitor be used for a 230 volt application?

No. The capacitor will short out and possibly explode. On the other hand, the 440 Volt Cap can be used in a 220 Volt circuit.


How do you change a 3 phase 440 volt motor to a 3 phase 220 volt motor?

You can not change it. 440 volt is by design. However you run it with 220 single phase supply, but it would run far lower power.


In a 440 volt and 220 volt or 100 volt feeder panel what do you call a component that monitor the wiring condition of the feeder?

Grounding monitor


How do you get single phase 440 from three phase 440?

You Don't. 440volt 3-phase is actually 480 volts, taking a single phase gives 277Volts single phase. To get single phase 440 you would use one leg of three phase 440/760 three phase power.


How do you connect 230 Volt single phase to a 440 circuit panel?

You can't get 230 from a 440 panel. You'll need a step down trandormer


You are measuring 480 volt from phase to phase and 280 volt phase to ground but one leg measures 440 volt phase to ground why?

Check for a blown fuse in one of the phase legs.


Can a 220 volt motor run on 440 volts?

No it will fry the motor use a voltege reducer


Why 440 volts running capacitor if my ac is 230 volts?

The 440 volts listed on the cap is the maximum allowable voltage the capacitor can handle. You could actually use a 370 volt cap on 230 volts. ANSWER; 230 volts AC can it actually be 644 volts peak to peak . It is 44ov because it must be rectified and sees only 324 volt peak which is withing the 440 volt capacitor handling voltage


What do the numbers mean on a 440 volt contactor?

The numbers on a 440-volt contactor typically indicate its voltage rating and operational specifications. For example, the "440" signifies that the contactor is designed to operate at a maximum voltage of 440 volts. Additional numbers may denote the current rating, number of poles, or specific model features, providing essential information for selecting the appropriate contactor for electrical applications. Always refer to the manufacturer's specifications for precise details.


What clearance 440 volt line to earth on road crassing?

The clearance for a 440-volt line to earth at a road crossing typically depends on local regulations and safety standards. Generally, overhead power lines should maintain a minimum clearance of about 5.2 meters (17 feet) above roadways to ensure safety for vehicles and pedestrians. It's essential to consult local electrical codes and utility company guidelines for specific requirements in your area. Proper signage and warning systems should also be in place to alert motorists of the power lines.