The owners of any factories, workshops or homes which need a 3-phase supply would order 3-phase supplies from their local power companies.
For a very small 3-phase appliance (not a heater!), such as a small motor, solid-state power inverter units are available nowadays which can be powered from household 1-phase supply.
If you want to know how to convert a 1-phase to a 3-phase supply for high power applications it can be done using a motor/alternator set or a solid state invertor unit but to use these safely requires specialized equipment and electrical engineering knowledge. The full answer is too complicated to explain here.
But, in any case, the cost of installing the right equipment to do that would not be economic: it would be much cheaper to have a new outlet, wiring and breakers for a standard household 240 Volt AC single-phase supply installed by a licensed electrician and then buy a new or secondhand heater (or more than one heater!) to get the same heat output. ALWAYS CHECK WITH YOUR LOCAL WIRING SAFETY OFFICE BEFORE YOU ATTEMPT TO CHANGE ANYTHING
- ELECTRICAL SERVICE PANEL, BREAKERS, CABLES OR OUTLETS -
ON ANY ELECTRICAL POWER CIRCUITS
IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS JOB
SAFELY AND COMPETENTLY
REFER THIS WORK TO QUALIFIED PROFESSIONALS.
If you do this work yourself, always turn off the power
at the breaker box/fuse panel BEFORE you attempt to do any work AND
always use an electrician's test meter having metal-tipped probes
(not a simple proximity voltage indicator)
to insure the circuit is, in fact, de-energized.
If single phase - 2 wire service > two wires If single phase - 3 wire service > three wires If three phase - 3 wire service > three wires If three phase - 4 wire service > four wires US residential service is usually single phase 3 wire service: Two hots and neutral.
The term for the phase change from vapor to solid without passing through the liquid phase is called deposition. This process involves water vapor turning directly into ice without first becoming liquid water.
Sublimationis the process of transition of a substance from the solid phase to the gas phase without passing through an intermediate liquid phase. Sublimation is an endothermic phase transitionthat occurs at temperatures and pressures below a substance's triple point
To calculate the amperage for a 10kW heater on a 3-phase 220V system, use the formula: Amps = (kW x 1000) / (√3 x Volts). So, Amps = (10 x 1000) / (√3 x 220) = 26.18 amps per phase. Therefore, the total current drawn by the heater is 26.18 amps per phase multiplied by 3, which equals approximately 78.54 amps.
The phase change is called sublimation. In this process, a solid changes directly into a gas without passing through the liquid phase.
Most electrical equipment are either designed to work on Single phase (two wires) or Three Phase (three or four wires). Two phase equipment are non existent today. A single phase heater will require a single phase thermostat while a three phase heater will require a three phase thermostat.
If the heater is rated as a 3 phase 480 volt heater then a neutral is not needed. If the voltage stated is 277 volts three phase then a neutral is needed.
Not without other modifications. The circuits used to turn the solid state relay on will not be suitable for turning a contactor on.
The cheapest service to construct is a single phase service. A three phase service requires more equipment and materials to complete a service.
no
600v is a three phase service, where 347v is the L-N voltage (if grounded).
To answer this question the voltage of the heater must be given. I = W/E.
I'm sure this isn't what you want to hear, but you probably need to ask an electrician familiar with your service and what you want to connect. As a general answer, you can connect a 240v line to line resistive load like an electric water heater to any 240v source. If you also need the 240v to have 120v line to neutral, like a 240v electric stove that contains a 120v clock and oven light, then its possible if the 3 phase power is connected in a "high delta" configuration, and you connect to the correct leads. If you have a high delta service and want to ignore the 3-phase power service and wire most or all of the loads in the building as a single phase load, the utility may have to be consulted.
No. Three phase service is something that you would need to request from your power company. You'd need to not only have service, you also need to have an electrician run 3 phase service into your home.
There are zero amps in a 6kW 3 phase heater. Amperage is the result of dividing the Watts by the Voltage. A = W/E. Without stating the voltage the heater operates on the amperage can not be calculated.
The common household electrical service is usually rated as a single phase service. In North America there are a few 120/208 three phase services being put into larger homes.
If single phase - 2 wire service > two wires If single phase - 3 wire service > three wires If three phase - 3 wire service > three wires If three phase - 4 wire service > four wires US residential service is usually single phase 3 wire service: Two hots and neutral.