The owners of any factories, workshops or homes which need a 3-phase supply would order 3-phase supplies from their local power companies.
For a very small 3-phase appliance (not a heater!), such as a small motor, solid-state power inverter units are available nowadays which can be powered from household 1-phase supply.
If you want to know how to convert a 1-phase to a 3-phase supply for high power applications it can be done using a motor/alternator set or a solid state invertor unit but to use these safely requires specialized equipment and electrical engineering knowledge. The full answer is too complicated to explain here.
But, in any case, the cost of installing the right equipment to do that would not be economic: it would be much cheaper to have a new outlet, wiring and breakers for a standard household 240 Volt AC single-phase supply installed by a licensed electrician and then buy a new or secondhand heater (or more than one heater!) to get the same heat output. ALWAYS CHECK WITH YOUR LOCAL WIRING SAFETY OFFICE BEFORE YOU ATTEMPT TO CHANGE ANYTHING
- ELECTRICAL SERVICE PANEL, BREAKERS, CABLES OR OUTLETS -
ON ANY ELECTRICAL POWER CIRCUITS
IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS JOB
SAFELY AND COMPETENTLY
REFER THIS WORK TO QUALIFIED PROFESSIONALS.
If you do this work yourself, always turn off the power
at the breaker box/fuse panel BEFORE you attempt to do any work AND
always use an electrician's test meter having metal-tipped probes
(not a simple proximity voltage indicator)
to insure the circuit is, in fact, de-energized.
If single phase - 2 wire service > two wires If single phase - 3 wire service > three wires If three phase - 3 wire service > three wires If three phase - 4 wire service > four wires US residential service is usually single phase 3 wire service: Two hots and neutral.
The term for the phase change from vapor to solid without passing through the liquid phase is called deposition. This process involves water vapor turning directly into ice without first becoming liquid water.
To calculate the amperage for a 10kW heater on a 3-phase 220V system, use the formula: Amps = (kW x 1000) / (√3 x Volts). So, Amps = (10 x 1000) / (√3 x 220) = 26.18 amps per phase. Therefore, the total current drawn by the heater is 26.18 amps per phase multiplied by 3, which equals approximately 78.54 amps.
Sublimationis the process of transition of a substance from the solid phase to the gas phase without passing through an intermediate liquid phase. Sublimation is an endothermic phase transitionthat occurs at temperatures and pressures below a substance's triple point
This idea is not economic.It would cost more to convert it safely than buying one or more single phase heaters (either second-hand or new) to give the same heating effect.3-phase heaters are not usually intended for domestic use in homes, except for the latest new-builds which have 3-phase supplies. They are commonly used in industrial sites (factories, workshops, etc.) or large public areas (department stores, airline terminals, etc.) where a 3-phase power supply would be installed as standard at the site.As always, if you are in doubt about what to do, the best advice anyone should give you is to call a licensed electrician to advise what work is needed.Before you do any work yourself,on electrical circuits, equipment or appliances,always use a test meter to ensure the circuit is, in fact, de-energized.IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS JOBSAFELY AND COMPETENTLYREFER THIS WORK TO QUALIFIED PROFESSIONALS.
Most electrical equipment are either designed to work on Single phase (two wires) or Three Phase (three or four wires). Two phase equipment are non existent today. A single phase heater will require a single phase thermostat while a three phase heater will require a three phase thermostat.
If the heater is rated as a 3 phase 480 volt heater then a neutral is not needed. If the voltage stated is 277 volts three phase then a neutral is needed.
Not without other modifications. The circuits used to turn the solid state relay on will not be suitable for turning a contactor on.
The cheapest service to construct is a single phase service. A three phase service requires more equipment and materials to complete a service.
no
600v is a three phase service, where 347v is the L-N voltage (if grounded).
To answer this question the voltage of the heater must be given. I = W/E.
I'm sure this isn't what you want to hear, but you probably need to ask an electrician familiar with your service and what you want to connect. As a general answer, you can connect a 240v line to line resistive load like an electric water heater to any 240v source. If you also need the 240v to have 120v line to neutral, like a 240v electric stove that contains a 120v clock and oven light, then its possible if the 3 phase power is connected in a "high delta" configuration, and you connect to the correct leads. If you have a high delta service and want to ignore the 3-phase power service and wire most or all of the loads in the building as a single phase load, the utility may have to be consulted.
There are zero amps in a 6kW 3 phase heater. Amperage is the result of dividing the Watts by the Voltage. A = W/E. Without stating the voltage the heater operates on the amperage can not be calculated.
No. Three phase service is something that you would need to request from your power company. You'd need to not only have service, you also need to have an electrician run 3 phase service into your home.
If the 240V 3-phase service is 240V phase-to-phase, then you can get 240V single-phase by simply picking two phases (poles, as used in the question) and connecting the load across them. This is simply one third of a standard delta connection. If you need 120V/240V split phase, i.e. with a neutral, as used in residential services, you will need a transformer. If the service is actually a four wire "quadraplex" service, however, you will probably already have that 120V/240V with neutral connection phase available. In this case, you will need to pick the two phases correctly in order to get the proper 120V service half.
If single phase - 2 wire service > two wires If single phase - 3 wire service > three wires If three phase - 3 wire service > three wires If three phase - 4 wire service > four wires US residential service is usually single phase 3 wire service: Two hots and neutral.