There are per-engineered shunt trip solutions such as the Littelfuse LPSM that have a transformer that isolates the line voltage from the control voltage. You simply wire the N.O. contact on the float in the shunt trip isolated contacts.

User Avatar

Wiki User

12y ago

What else can I help you with?

Continue Learning about Natural Sciences

What can a loosely connected electrical wire in a breaker panel cause?

A short, which will trip the main breaker.


If live is kept open could it trip circuit breaker by connecting neutral to ground?

Yes, keeping a live wire open can potentially trip a circuit breaker if the neutral and ground are connected. This can create a potential difference between neutral and ground, leading to a fault current that may trip the breaker. It is unsafe to have a live wire left open and in contact with other conductors.


How do you tell if a wire is shorted out?

If a wire is shorted out, you may notice sparks, smoke, or a burning smell coming from the wire. You can also use a multimeter to test for continuity between the two ends of the wire - if there is continuity, it indicates a short circuit.


Can a circuit breaker be tripped by using 20 amp sockets instead of 15 amp sockets?

A circuit breaker protects the wires that the devices are connected to. If the devices that are connected to the circuit are 20 amps the wire size should be #12 wire fed from a 20 amp breaker. This breaker should not trip unless the circuit is overloaded or a fault occurs on the circuit. If the devices that are connected to the circuit are15 amps the wire size should be #14 wire fed from a15 amp breaker. This breaker should not trip unless the circuit is overloaded or a fault occurs on the circuit. Putting 20 amp sockets on this 15 amp circuit will work but the circuit is limited to the amount of load that can be plugged in. You will not get the full capacity of the 20 socket because the breaker will trip at 15 amps.


Why does the breaker continue to trip until hot wire is disconnected?

There is a short somewhere in the line. Start at the outlet end and what is plugged into it and work your way back. If it is a GFI breaker, they can be bad and trip as soon as any drain is put on them. I have had them trip as soon as a drill is plugged in without even turning on the drill.

Related Questions

How do you hook up wire from ansul system to shunt trip breaker?

You would need to take the "input" wire for the shunt trip breaker to an electrical switch (not alarm initiating switch, which are DC voltage rated) within the Automan unit and connect to the "Common" connection and the "return", the wire to the actual shunt circuit of the breaker, from the "Normally Open" connection of the switch. When the unit activates, the switch will be placed into "Closed" position, therefore completing the circuit and activating the shunt coil.


How do you tell the difference between square d 3 pole 50a breaker and square d 3pole 50a breaker with shunt trip?

the easiest way to tell, is the shunt trip breaker will actually take up 4 spaces in your panel. the 4th space will have a neutral wire coming out of it, along with a lug for power INPUT. when voltage is applied to the shunt trip, it will cause the other 3 poles to open by tripping the breaker.


How and where do you connect the white wire from the shunt breake to the electrical panel?

The white wire would go to the neutral bar. Just be sure of the shunt trip voltage required for the breaker and land the white wire on the appropriate neutral bar in the correct panel.


Where do you connect the white wire from the shunt breaker?

Connect to the circuit neutral wire which should also be white.


Can a loose wire cause a breaker to trip?

Yes, a loose wire can cause a breaker to trip. When a wire is loose, it can create a short circuit or excessive heat, which can trigger the breaker to trip as a safety measure to prevent electrical hazards.


What is difference between shunt trip and ground fault circuit breaker?

Ground fault breakers monitor the current on the neutral wire flowing back to the neutral bar, a 4 to 6mA difference will trip the breaker, Shunt trip breakers on the other hand can be tripped remotely from some other type of switch or location. In industrial applications it is used to shut power off in an emergency situation, when access to an electrical panel may denied.


What can a loosely connected electrical wire in a breaker panel cause?

A short, which will trip the main breaker.


How do you wire a GFCI breaker?

To wire a GFCI breaker, first turn off the power to the circuit. Then, connect the hot wire to the breaker's terminal, the neutral wire to the neutral bar, and the ground wire to the ground bar. Finally, turn the power back on and test the GFCI breaker to ensure it is working properly.


How to wire a GFCI breaker correctly?

To wire a GFCI breaker correctly, first turn off the power to the circuit. Then, connect the hot wire to the breaker's terminal, the neutral wire to the neutral bar, and the ground wire to the ground bar. Finally, turn the power back on and test the GFCI breaker to ensure it is working properly.


Why does the circuit breaker keep tripping immediately?

The circuit breaker may keep tripping immediately due to a short circuit, which occurs when a hot wire comes into contact with a neutral wire or ground wire. This causes a sudden surge of electricity, triggering the circuit breaker to trip for safety reasons.


If live is kept open could it trip circuit breaker by connecting neutral to ground?

Yes, keeping a live wire open can potentially trip a circuit breaker if the neutral and ground are connected. This can create a potential difference between neutral and ground, leading to a fault current that may trip the breaker. It is unsafe to have a live wire left open and in contact with other conductors.


Why are electric ranges wired to separate circuit breaker?

As a range is a high current device, the electrical code stipulates that it has to have its own breaker. The breaker protects the wire feeder. An electric range breaker is set to trip at 40 amps. Using a smaller wire that #8 is not allowed as their ratings are below that of the #8 wire. #10 wire rating is 30 amps, #12 wire rating is 20 amps, and #14 wire rating is 15 amps.