In Canada from grade to five feet for mechanical protection.

User Avatar

Wiki User

15y ago

What else can I help you with?

Continue Learning about Natural Sciences

What is the difference between thhn and romex?

THHN is a heat resistant thermoplastic insulated conductor, usually a single conductor. Romex is a brand name for a nonmetallic sheathed cable, it has multiple conductors inside, the insulated ones are insulated with THHN insulation.


Is that possible to run romex wire to the under ground basement?

No, it is not possible to run Romex wire directly underground in a basement. Romex wire is not rated for direct burial underground and should not be used in this application. Instead, you should use UF-B (underground feeder) cable or conduit with appropriate wiring for underground installations.


What is the maximum degrees bending for conduit?

its 180 degrees If you use the above answer the conduit will flatten and close off. The maximum degrees for a single bend in conduit is 90 degrees. Also code only allows four 90 degree bends in a conduit run between pull boxes.


Is splicing ok in a conduit body?

The conduit body or box has to be clearly marked for its fill capacity for wires or devices. So Long story short, Yes as long as the conduit body is listed for it. If it has no markings then no


Can you use romex in a commercial building?

Romex, or non-metallic sheathed cable (NM cable), is generally not permitted for use in commercial buildings due to stricter electrical codes and regulations that apply to commercial installations. Instead, commercial buildings typically require the use of conduit systems or other types of wiring methods that provide greater protection and durability. Always consult local building codes and a licensed electrician to ensure compliance with applicable regulations.

Related Questions

Can you run Romex wiring in conduit?

No, Romex wiring cannot be run in conduit as it is not designed or approved for use in conduit.


Is it permissible to run Romex cable in conduit?

Yes, it is generally not permissible to run Romex cable in conduit because Romex is already insulated and designed for use without additional protection. Running Romex in conduit can lead to overheating and potential fire hazards.


Is it permissible to put Romex wiring inside conduit?

Yes, it is generally not recommended to put Romex wiring inside conduit as it can cause overheating and potential safety hazards. Romex wiring is typically designed for use without conduit.


What are the best practices for installing Romex in conduit to ensure safety and compliance with electrical codes?

The best practice for installing Romex in conduit is to not do it. Romex, which is a type of non-metallic cable, should not be installed in conduit as it can lead to overheating and potential fire hazards. Instead, use individual THHN or THWN wires in conduit for safety and compliance with electrical codes.


Can a remodel job be wired with romex if the home is wired with conduit?

Yes unless there were some overarching electric code reason why conduit was used in lieu of Romex. if in doubt ask an electrician.


Why can't you run Romex in conduit?

Romex cable cannot be run in conduit because it is not designed to be used in that way. Romex is a type of non-metallic sheathed cable that already has its own protective outer jacket. Running it in conduit can cause overheating and damage to the cable, potentially leading to a fire hazard. It is important to follow the manufacturer's guidelines for proper installation of Romex cable.


What are the advantages of using Romex conduit for electrical wiring installations?

The advantages of using Romex conduit for electrical wiring installations include easier installation, protection of wires from damage, and compliance with building codes.


What is the difference between thhn and romex?

THHN is a heat resistant thermoplastic insulated conductor, usually a single conductor. Romex is a brand name for a nonmetallic sheathed cable, it has multiple conductors inside, the insulated ones are insulated with THHN insulation.


Is romex allowed in a room addition burbank ca?

yes


Is it safe for Romex wiring to be exposed in a residential setting?

No, it is not safe for Romex wiring to be exposed in a residential setting as it can pose a risk of electrical shock or fire hazard. It should be properly installed and protected within walls or conduit.


What is the maximum fill capacity allowed for NEC conduit fill in electrical installations?

The maximum fill capacity allowed for NEC conduit fill in electrical installations is 40.


Is that possible to run romex wire to the under ground basement?

No, it is not possible to run Romex wire directly underground in a basement. Romex wire is not rated for direct burial underground and should not be used in this application. Instead, you should use UF-B (underground feeder) cable or conduit with appropriate wiring for underground installations.