If they are in different rooms or side by side in the same room, and not connected together mechanically, there should not be a problem.

User Avatar

Wiki User

12y ago

What else can I help you with?

Continue Learning about Natural Sciences

How can you run a 380VAC 3-phase 50hz motor on a 220VAC 3-phase 60hz supply?

To run a 380VAC 3-phase 50Hz motor on a 220VAC 3-phase 60Hz supply, you would need to use a voltage converter to step up the voltage from 220VAC to 380VAC. Additionally, you may need to adjust the motor's parameters to account for the difference in frequency between 50Hz and 60Hz, such as adjusting the motor's speed rating and ensuring the motor does not overheat due to the increased frequency. It's important to consult an electrician or motor specialist to ensure safe and proper operation.


How do you connect a 460V 3 phase motor 60Hz with 380V 50Hz 3 phase supply?

You can use a voltage converter to step down the 460V 3 phase motor to match the 380V 50Hz supply. Make sure the converter can handle the motor's current requirements. It's also advisable to consult with an electrician to ensure safe and proper installation.


Can you use a machine that runs on 110v50hz in USA?

Short answer no. But in reality it depends on what the machine is and how well it is built. Know that if the correct operation of the machine depends on the motor running at the correct speed, then running a 50Hz machine on 60Hz will cause it to run at the wrong speed. The motor will turn faster. This will put a strain on the wiring and it very well may fail prematurely.


What are the standard colors for the Hots in a 3 phase 60Hz mains supply in the US and are these same colors also standard in other countries which use 60Hz 3 phase supplies?

For 120/208v systems the colors are black - red - blue with a white neutral. For 277/480v and higher systems the colors are brown - orange - yellow with a grey neutral. Countries outside of North America generally use different colors.


I have a coolant motor with 420 volts in Lathe Machine but the supply voltage will be 480 volts. Can 420 volts 50Hz coolant motor can use in 480 volts 60Hz?

No, you'll burn your lathe motor up immediately. (it might last 30 seconds before it literally smokes.) You'll need to buy and install a "buck-boost" type transformer to drop the voltage from 480 to 420V. Best to have a qualified commercial electrician wire it up if you value your lathe.

Related Questions

What is the result of running a 460 volt 3 phase 60hz motor with 415 volts 3 phase 50hz?

It will run hotter. It will run slower, about 83% of nameplate speed. It will draw more than the nameplate current. You will only be able to get about 3/4 of rated horsepower. If the motor is loaded to more than this, it will not live very long.


3 phase reverse relay can be utilized for motor control speed?

3 phase reverse relay can be utilized to control 480V motor 60HZ for controlling their speedspeed.


How can you run a 220v 3-phase 60hz motor on a 380v 3-phase supply?

Not advisable, the voltage differential is too great.


How can you run a 380VAC 3-phase 50hz motor on a 220VAC 3-phase 60hz supply?

To run a 380VAC 3-phase 50Hz motor on a 220VAC 3-phase 60Hz supply, you would need to use a voltage converter to step up the voltage from 220VAC to 380VAC. Additionally, you may need to adjust the motor's parameters to account for the difference in frequency between 50Hz and 60Hz, such as adjusting the motor's speed rating and ensuring the motor does not overheat due to the increased frequency. It's important to consult an electrician or motor specialist to ensure safe and proper operation.


How can you determine if an electric motor is 50HZ or 60HZ if there is no name plate?

One way would be to hook it up to a supply (by itself, with no load) and measure the speed with a contact tachometer. If your supply is 60Hz, and the motor speed corresponded to one of the standard motor speeds, it would be a pretty safe bet you had a 60Hz motor. If the speed was about 20% faster than a standard speed, the motor is probably a 50Hz motor. Or 20% slower if you were running a 60Hz motor on 50Hz For instance, a 1750 RPM 50Hz motor would spin at about 2100 RPM if you ran it on 60Hz.


How do you connect a 460V 3 phase motor 60Hz with 380V 50Hz 3 phase supply?

You can use a voltage converter to step down the 460V 3 phase motor to match the 380V 50Hz supply. Make sure the converter can handle the motor's current requirements. It's also advisable to consult with an electrician to ensure safe and proper installation.


Can a vfd be run any higher than 60hz?

Yes, most VFDs can run faster than the input power frequency so you can run a motor to 60Hz with a 50Hz power source. Just be aware that as speed increases, so will the current. Also be aware that a motor is rated to run a specific rpm and running faster may cause motor bearing failure after a short time.


What is impact ampere in 50Hz motor connected to 60Hz?

What effect will be there on the motor (Induction) output power when a 100kW 50hz motor is connected to a 60hz power supply.


How do you connect a 230volt 60Hz air conditioning unit with one phase wire to a 240 volt 60Hz two phase south American supply?

Treat the USA 2 Phases as 1, its called split phase, instead of Line and Neutral, you ahve two phases but they deliver 240v, this will not hurt a 230v machine as the chances are that you are NOT getting 240v supply at the delivery point anyway. As long as the machine si 60Hz and supply 60Hz, you will not have a problem


Can you run a 460v 60hz motor to a 480v supply?

The the supply stays within +/- 5% of what the motor is rated for, you can do this.


How does 50hz and 60hz differ from one another?

ONE THING FOR SURE THERE IS NO CHANGE IN VOLTAGE IF SAME EQUIPMENT WE ARE TALKING ABOUT. THE ISSUE HERE IS THE CHANGING LOAD FREQUENCY 60HZ TO 50HZ OR VICE VERSA. FOR EXAMPLE THE MOTOR HORSEPOWER AND R.P.M. WILL BE APPROXIMATELY 90 AND 83 PERCENT OF THE NAMEPLATE SPECIFICATIONS, ALSO THE FULL LOAD RUNNING TORQUE WILL INCREASE APPROXIMATELY 8 PERCENT IF USED FROM 60HZ TO 50HZ.


How do you convert 120VAC 60Hz to 208 230 1 Phase?

you need a step up transformer