Arcing between the bus bar and a breaker could be caused by loose connections, excessive load on the circuit, corrosion or physical damage to the components, or poor installation. It is important to investigate and address the root cause promptly to prevent damage and ensure safety.
For a typical 12-2 wire, the black wire is the "hot" wire that connects to the breaker, the white wire is the neutral wire that connects to the neutral bus bar, and the bare copper wire is the ground wire that connects to the ground bus bar in the circuit panel.
Depends on the wire size used in the circuit. If you use AWG # 14 wire you must use a 15 amp breaker. If it is wired with AWG # 12 wire then you use a 20 amp breaker. If a AWG # 10 wire is used then a 30 amp breaker is required. The breaker protects the wiring from overheating so you must use the proper size breaker for the wire used.
On a 15 amp household breaker there is no terminal on the in feed of the breaker. The breaker either plugs into the distribution panel's bus bar or it bolts to the distribution's bus bars. The feed conductor connects to the load side of the breaker at its terminal lug.
Answer for USA, Canada and countries running a 60 Hz supply service.Breakers are rated in amperage and by the amount of poles that they have. Your classification of a 220 breaker is described in electrical terminology as a two pole breaker.Choosing the amperage of the two pole breaker depends upon the 220 volt load that it feeds.Two pole breakers for 220 volt loads.Single pole breakers for 120 volt loads.If the service is only 120 volt then every other bus bar in the panel will be energized. If the panel is a 120/240, then every bus bar in the panel will be energized.This is how and why a 240 volt load requires a two pole breaker.To the answer, yes you an use a two pole breaker in a 120 volt service but only one side of the breaker will have voltage on it depending on where it is situated in the panel board.
a breaker bar is longer then a ratchet so you leverage
Use a breaker bar and appropriate sized socket Use a breaker bar and appropriate sized socket
get the Schley tool that holds the crank. use a good 1/2" breaker bar to hold the Schley and a 3/4" breaker bar with 22mm socket to loosen the nut
The panel and breaker have to be of the same manufacturer. This way the breaker will fit into the panel. If the panel has a push in bus bar, the breaker must also be the type to accept the bus bar. If the bus bars in the panel are of the bolt in type then the breaker also has to be a bolt in breaker.
Use a breaker bar or rachet to move tensioner out of the way
Ground wire connects to the ground bar, white wire connects to the neutral bar, and black wire connects to the breaker. Be sure and turn off main breaker before installing the wire or the breaker.
No
Use a breaker bar to loosen the tensor wich is directly below the Alternator on the 3.0 V6. While the breaker bar holds the tensor down (loose) slide on the new belt via the diagram in the compartment.
Use a 1/2" drive breaker bar in the tensioner.
Use a socket with a long breaker bar and a gear puller.
To wire an AFCI breaker, first turn off the power to the circuit. Then, connect the hot wire to the breaker's terminal, the neutral wire to the neutral bar, and the ground wire to the ground bar. Finally, snap the breaker into place in the electrical panel.
I use a 24" pipe wrench to hold the yoke, and a big breaker bar with a cheater bar to tighten the nut.