answersLogoWhite

0

The Bio-Rad protein assay measures the total protein content in a sample at 595 nm because this wavelength corresponds to the absorption peak of protein-bound Coomassie Brilliant Blue dye. When proteins are present in the sample, they bind to the dye, causing a shift in absorbance at 595 nm, which is used to accurately quantify the protein concentration.

User Avatar

AnswerBot

1y ago

What else can I help you with?

Continue Learning about Natural Sciences

How can an icteric hemolyzed or lipemic sample be corrected for total protein assay?

An icteric sample can be corrected by using a method that does not rely on colorimetric detection, such as turbidimetric or refractometric methods. Hemolysis can be corrected by using a spectrophotometric method that measures protein concentration at a wavelength where hemoglobin absorption is minimal. Lipemia can be corrected by using ultracentrifugation or filtration to remove the lipids before analyzing the sample for total protein.


What major plasma protein is involved in the interpretation of how calcium is measured?

The major plasma protein involved in the interpretation of how calcium is measured is albumin. Albumin binds to calcium in the blood, and changes in albumin levels can affect the total calcium concentration. Therefore, total serum calcium measurements may need to be adjusted for albumin levels to accurately assess the biologically active (ionized) calcium. This adjustment is crucial for diagnosing and managing conditions related to calcium metabolism.


What is the formula for calculating assay and potency?

Assay is typically calculated as the percentage of the active ingredient present in a sample compared to the total sample weight. Potency is a measure of the strength or concentration of the active ingredient in a sample relative to a standard reference. The formula for assay and potency calculations may vary depending on the specific assay method and the properties of the substance being analyzed.


Does total activity increase or decrease during protein purification?

During protein purification, the total activity of the protein is typically maintained or even increased due to the removal of unwanted contaminants. Purification processes are designed to concentrate and purify the target protein, which can lead to an increase in specific activity even if some total protein is lost during the process.


Where was speed measured?

It is the total distance travelled divided by the total time taken.

Related Questions

What is protein assay?

Protein assay is the determination of concentration or total level of protein in a solution.There are various protein assays employed like bradford assay and lowry assay


What is the molar mass of the protein?

The molar mass of a protein is the total mass of all the atoms in one mole of that protein. It is typically measured in grams per mole (g/mol).


How can an icteric hemolyzed or lipemic sample be corrected for total protein assay?

An icteric sample can be corrected by using a method that does not rely on colorimetric detection, such as turbidimetric or refractometric methods. Hemolysis can be corrected by using a spectrophotometric method that measures protein concentration at a wavelength where hemoglobin absorption is minimal. Lipemia can be corrected by using ultracentrifugation or filtration to remove the lipids before analyzing the sample for total protein.


What is the advantages of using biuret reaction in place of measuring the absorption of the protein solution at 280 nm?

The absorption of proteins at 280nm is according to electrons from the rings on the amino acid such as His, Trp, etc. And if there is no such kind of amino acids in the protein, we might not be able to get what the amount of the protein really is. At the other hand, what makes biuret reaction work is by the copper ion reacting with the dipeptide bonds, since every amino acid has the peptide bond, it's more accurate and reasonable to use biuret reactions to determine what the amount of the protein is.


What does Assay of psa total 84153-GA mean on a lab bill?

"Assay of PSA total 84153-GA" means the patient had a PSA (prostate specific antigen) test done. This is a common screening test in men in middle age and older. 84153 is the CPT code for the test.


Why incubate the samples at 37C in the total phenolic assay?

Incubating the samples at 37°C in the total phenolic assay helps to promote the activity of the enzymes responsible for phenolic compound extraction and detection. This temperature mimics physiological conditions and enhances the efficiency of phenolic compound extraction from the sample matrix.


What does T Protein indicate on a blood test?

T protein = Total protein


What is the formula for calculating assay and potency?

Assay is typically calculated as the percentage of the active ingredient present in a sample compared to the total sample weight. Potency is a measure of the strength or concentration of the active ingredient in a sample relative to a standard reference. The formula for assay and potency calculations may vary depending on the specific assay method and the properties of the substance being analyzed.


What is Tot Protein?

"Tot Protein" is short for "total protein." The total protein test is a rough measure of all the proteins found in the fluid portion of your blood. Specifically it looks at the total amount of two classes of proteins: albumin and globulin.


How is ascitic fluid measured for diagnosis of ascites?

includes a total polymorph count, protein and albumin concentrations, and placement of at least 10 ml of ascitic fluid each into blood culture bottles for processing.


How can you measure your cholesterol ratio?

Cholesterol ratio can be measured by dividing one's high-density lip-protein (HDL) Cholesterol into one's total cholesterol. It is very important to keep a track of one's Cholesterol ratio.


Does total activity increase or decrease during protein purification?

During protein purification, the total activity of the protein is typically maintained or even increased due to the removal of unwanted contaminants. Purification processes are designed to concentrate and purify the target protein, which can lead to an increase in specific activity even if some total protein is lost during the process.