The sub-cooling or under-cooling in the saturated liquid line increases the refrigeration effect or cooling effect, thus the COP of VCR system increases.
Disadvantages of vapor compression refrigeration system include potential leaks of refrigerant gases, environmental impact of fluorinated gases, energy consumption for compression, and complexity of maintenance and repairs.
A Vapour Absorption Machine (VAM) is a type of refrigeration system that operates on the principle of heat absorption. It uses a refrigerant-absorbent pair to produce cooling by absorbing heat from a space and releasing it elsewhere. VAMs are commonly used in industrial applications and areas where waste heat or low-grade heat is available.
There are two basic cycles of Airconditioning/Refrigeration 1. Vapour compression cycle, 2. Vapour Absorption Cycle Vapour compression cycle is used in most of the airconditioning applications but ofenly vapour absorption is used. evaporator, compressor, throateling valve, tank & condensor are the major parts of this cycle.
When humidity is high, the air is already saturated with water vapor, so there is less room for additional water molecules to evaporate from a wet surface. This reduces the concentration gradient needed for evaporation to occur, leading to a decrease in the rate of evaporation.
In British English, the verb of vapour is vaporise.In American English, the verb is vaporize.Other verbs depending on the tense are vaporises (US - vaporizes), vaporising (US - vaporizing) and vaporised (US - vaporized),
Mahit Nahi
Disadvantages of vapor compression refrigeration system include potential leaks of refrigerant gases, environmental impact of fluorinated gases, energy consumption for compression, and complexity of maintenance and repairs.
Brian Mongey has written: 'The experimental evaluation of a ternary mixture as an alternative to R22 in the vapour compression refrigeration cycle'
Vapour compression refrigeration systems have several disadvantages, including energy inefficiency, as they often require significant electrical power to operate compressors. They also rely on refrigerants that can have high global warming potential and may contribute to ozone depletion if leaked. Additionally, these systems can be complex and costly to maintain, as they involve moving parts that are susceptible to wear and tear. Finally, they may not perform efficiently in extremely high or low ambient temperatures.
in orde to reduce the pressure........cming from the evaporator
See my answer to~How does air conditiong work~ on this site.
A Vapour Absorption Machine (VAM) is a type of refrigeration system that operates on the principle of heat absorption. It uses a refrigerant-absorbent pair to produce cooling by absorbing heat from a space and releasing it elsewhere. VAMs are commonly used in industrial applications and areas where waste heat or low-grade heat is available.
In vapour compressor refrigeration system the low pressure and temperature vapour refrigerant from evaporator is compressed. where it is compressed to a high pressure and temperature. From compressor refrigerant goes to condenser where where it changes the phase. from condenser refrigerant goes to evaporator through expansion device.
To minimize sweating of the air around the pipe. When the air comes in contact with a cool surface, its water vapor condenses!
G. A. Hewett has written: 'Mechanical heat pump (vapour compression refrigerator)'
In vcrs system there is a phase conversion system i.e. liquid state to gases state and this happens with latent heat of working medium but on the other hand there is only gases expansion on expander cylinder and no phase changes occurs and in cylinder we can not expend two phase system..
When temperature is increased the amount of molecules evaporated is increasef and as a consequence condensation is also increased so vapour pressure increases.