Starting current is the current for starting the motor initially. So it requires much more current than it of normal condition.
Full load current is the current for maximum current to keep the motor.
A fuse is a safety device that breaks a circuit when current exceeds a certain level, protecting the circuit from overheating and potential damage. A circuit is a path that allows electricity to flow, connecting components like switches, resistors, and capacitors to create a functional electrical system.
Overcurrent protection is protection against excessive currents or current beyond the acceptable current rating of equipment. It generally operates instantly. Short circuit is a type of overcurrent. Overload protection is a protection against a running overcurrent that would cause overheating of the protected equipment. Hence, an overload is also type of overcurrent. Overload protection typically operates on an inverse time curve where the tripping time becomes less as the current increases.
Rated cooling capacity represents the actual cooling output that the air conditioner can provide under specific conditions, while nominal cooling capacity is the manufacturer's stated maximum capacity in ideal conditions. The rated cooling capacity is a more accurate representation of a unit's performance in real-world scenarios.
A battery is rated to supply a certain number of volts. However, it actually supplies less, because they are "lost" as the current has to get out of the battery in the first place.(The battery has internal resistance)The amount of lost volts depends on the current being drawn:The less resistance a circuit has, the more current is drawn, because it's easier to flow.Example:If the circuit has little resistance, it draws a large current and the battery's internal resistance causes more lost volts.If the circuit has high resistance, it draws a small current and there are fewer lost volts.This is why when you short-circuit a battery (give it hardly any resistance to go through) it heats up and may explode. A large current is drawn and all the volts are used by the battery's internal resistance.
Full load amps is the maximum rated amps that the motor should draw according to its nameplate rating. Running load amps is the actual amperage the motor is drawing at that point in time when the test is taken. Some motor loads vary depending on if the load is cyclic. The reading on this type of motor would be from no load amps to full load amps.
They are the same.
What is the difference between rated capacity and the nominal capacity
MCB stands for miniature circuit breaker , which provides protection against over current. the setting is not adjustable. RCB stands for residual circuit breaker which provides protection against earth fault as well as over current. It monitors the current difference between phase and neutral and if the difference is more than rated value say 200 milli amps it will trip.
"Rated current" is the current the device (motor or transformer?) is designed to handle at full load. "Tripping current" is the current where a protective device (fuse, breaker) will open to protect the device from overload/overheating. "Tripped current", may be the current the tripping device measured prior to making the decision to trip, if you are reading this from a digital protective device like a relay or OCR.
The B,C,D,K,Z indicates the instantaenous tripping current. It means the minimum value of current causes the circuit to trip without intentional time delay. approximately < 100ms. Consider Rated Current be : (In) Instantaenous tripping current for C Curve is 5-10 times the rated current(In). Instantaenous tripping current for D Curve is 10-20 times the rated current(In).
rated current is the current at any given conditions......but full load current is the maximum current that the system design can hav.....it w'll b larger than that f the rated current. rated current is the current at any given conditions......but full load current is the maximum current that the system design can hav.....it w'll b larger than that f the rated current.
class III rated for up to 5,000lbs, class IV is rated for up to 10,000lbs towing capacity
MCB (Miniature Circuit Breaker)-rated current not more than 100 A. Trip characteristics normally not adjustable. Thermal or thermal-magnetic operation. Breakers illustrated above are in this category.MCCB (Molded Case Circuit Breaker)-rated current up to 2500 A. Thermal or thermal-magnetic operation. Trip current may be adjustable in larger ratings. MCB (Miniature Circuit Breaker)-rated current not more than 100 A. Trip characteristics normally not adjustable. Thermal or thermal-magnetic operation. Breakers illustrated above are in this category.MCCB (Molded Case Circuit Breaker)-rated current up to 2500 A. Thermal or thermal-magnetic operation. Trip current may be adjustable in larger ratings.from Manu anand
Maximum current is defined by the rated KW of the device, say Motor. The motor may not run at its maximum rated capacity all the time. Nominal current is drawn when motor runs at nominal load.
Non negotiable bill of lading
rated rpm is the maximum number of complete rotations that a rotor can rotate for every minute
teen-13 and overmature-18 and over