New Electrical Work

Electrical work ranges from the installation of new electrical components to the maintenance and repair of existing electrical infrastructure. It may also include wiring airplanes, ships and other mobile platforms.

4,938 Questions

What is the Electrical supply IN THE UK?

Home electrical service in the UK is 230 volts at 50 hertz.

What does P1 stand for in electrical wiring?

P1 is where you hook L1 on electric motors. Typically used on 220v motors in the wiring diagram. P1 (phase 1) gets connected to L1 (power leg)

How do you activate 240v coil using a 240v contactor?

The coil can be operated by taking one leg of the 240 volts from the top of the contactor and connecting it to one terminal of the coil. Take the other leg of the 240 volts from the top of the contactor and connect it to the device used to turn the contactor off and on. From this switching device take the switched wire and connect it to the other terminal on the contactor's coil. Now when the switching device is activated the contactor will open and close.

Before you do any work yourself,

on electrical circuits, equipment or appliances,

always use a test meter to ensure the circuit is, in fact, de-energized

IF YOU ARE NOT REALLY SURE YOU CAN DO THIS JOB

SAFELY AND COMPETENTLY

REFER THIS WORK TO QUALIFIED PROFESSIONALS.

What is more powerful 1000 watts or 12 amps?

Watts = Amps x Volts x Power Factor

You can't answer your question because watts and amps are two different things. Watts is a measure of power and amps measures current flow.

Additional informationPower factor refers to the efficiency of an electrical device. Power factors can have a value of between 0 and 1, with 1 representing perfect efficiency of an electric motor or similar device. In most applications, power factor is ignored and assumed to be 1.

Using the above formula, you can see that 12 amps at 1 volt would be only 12 watts, while 12 amps at 120 volts would be 1440 watts.

Given this information, you should be able to calculate the answer in your circumstance.

How safe is a 1969 zinsco electrical panel?

They are not at all safe and are junk that needs to be recycled and never installed even in a barn let alone a home. Zinsco company went out of business partly because it was discovered that their breakers did not trip when they were supposed to. For this reason they are nothing but a fire hazard and are not to be trusted to protect the wiring in your home or your family from a fire. Do not use any Zinsco or FPE service panel. Destroy this panel so that no one can ever use it.

Will 16mm twin dc cable fit into 25mm conduit?

If 16mm is the overall diameter of the cable, yes - If that's the diameter of one core, then no.

What size breakers are needed for two 500 watt baseboards?

Each baseboard heater will draw a little over 4 amps at 120 volts or 2 Amps at 240 volts. The total number of baseboards on a circuit will draw the sum of these amps. Keep the load under 80% of the amperage rating of the breaker.

How much area will a 2 tube 4' fluorescent light fixture cover?

Depends on how high it is off the floor. Make sure you buy a T8 and not a T12. The T8 puts out more light and will operate at a lower temperture. On a normal 8' ceiling a 2 bulb T8 will cover around 36 square feet of space. If the room is pretty large then an 8 foot 2 bulb HO light is a much better choice.

How can I convert a cord to a plug?

You can't but you can install a plug on the end of a cord. Just go purchase one and install it. Very simple to do. Black wire goes to copper screw, white wire goes to silver screw, and ground or green wire goes to ground screw. It both wires are brown then connect the wire with the ridges on the outside of the wire to the silver screw as it is the neutral. The wire that is smooth is the black hot wire which connects to the copper screw.

When is it permissible to wire tie a wire to a conduit?

What kind of wire?

If it's a power wire, why is the place wired with conduit?

Commercial buildings must put all power wiring in conduit, so if you're planning to run romex in a commercial building, the answer would be "no", it's not permissible.

If it's data wire, note that there may be some "crossover" interference if the data wire follows a power wire for very much distance. It's usually not a problem to cross a conduit and tie to it, but it's generally recommended that you not tie data cable to conduit.

What is RTU panel?

RTU Panel Means: Where RTU electronic along with other accessories each positioned comfortably for normal operation and maintanence.

Rgds,

Tech Lead.

Can 600v wire works 30 amp fuse?

What size is the wire? AWG 10, 600V is rated for 30 amps. Any AWG less than 6 would also be ok for a 30 amp circuit....

Can I get electrocuted touching an electric pole if I'm not grounded?

First off you should not be touching any high voltage source whether you are grounded or not. A pole isn't typically dangerous, it is the wires on the pole. A path to ground is required for a current to flow. Technicians working on high voltage power line often touch the lines and ensure they are not grounded when doing so, by using special procedures. That is why birds can sit on bare power lines without getting shocked.

Why isn't there a ground in a junction box?

Only the main panel is grounded directly because if you ground each junction box of subpanel ground loop current paths are possible that can cause shock hazards. The ground rod is connected to main panel and the neutral is bonded to that ground as is the ground wire. The neutral and ground wire are then run to all circuits, junction boxes and subpanels throughout the house.

If you tie neutral and ground together at any point in the house, other than the main panel ground loops can exist and cause shocks.

Can you power a trane variable speed blower 2 stage furnace with a 12v power inverter in a power outage?

That depends entirely on the capacity of the inverter.

There are inverters with sufficient capacity to operate a 3/4 HP blower motor; a 1,000 watt inverter should have adequate capacity to provide extended power to the blower motor.

How do you install pull chain switch into existing Fluorescent lamp?

Installing a pull chain switch into an existing fluorescent lamp includes both mechanical and electrical issues. One has to change the wires and the switch mounts to have the two be compatible within the same fixture.