4,000+ ft BUT it has to be vented properly with the correct pitch and treated as a soil horiziontal line and then the vent calculated on the developed lenght or pipng and fittings and allow for cleanouts at every change of direction greater then 45 Deg and install a clean out every 50 ft at a right angle to the soil line flow. BUT check your local code as some have no clue to proper venting
Maximum distance of the toilet to the drain is 6 metres (20 feet). The angle of drop is set by the branch at 112 1/2o, which equates to about 1/4" of drop per foot.
A cast iron toilet flange adapter is used to connect a toilet to a cast iron pipe. It serves the purpose of providing a secure and watertight connection between the toilet and the pipe. The adapter helps to ensure proper alignment and stability of the toilet on the cast iron pipe, preventing leaks and ensuring efficient waste removal.
50m
The maximum distance allowed between two manholes for a drainage system with a 48-inch diameter pipe typically ranges from 300 to 400 feet, depending on local regulations and the specific design requirements of the system. This distance ensures effective maintenance access and proper flow management. However, it's essential to consult local codes and guidelines, as these can vary by jurisdiction.
toilet should have a vent with in three feet of down pipe, but as long as you are with in the drop range for hori. pipe run you can go as far as you want, but you need that air vent close as you can so that the suction from the toilet water does not pull the rest of water from toilet base(p trap).
The main toilet pipe is partly plugged after where the upper pipe joins the lower one.
The purpose of a toilet flange wax ring is to create a watertight seal between the toilet and the waste pipe. It helps in the installation of a toilet by preventing leaks and odors from escaping, ensuring a secure and sanitary connection between the toilet and the plumbing system.
Yes if the vent pipe is 4" and vertical by code and there is nothing connected between your toilet tee and where you would connect your new toilet tee. If not worried about codes then yes you can connect to a 3" vent line if no other vent lines are connected down stream. If you have a vent pipe that is less then 3" and or you have other vents connected between your old toilet tee and your new toilet tee then NO you can not connect a new tee for your toilet.
It's not the toilet, there's a blockage in the pipes some where after the drain pipe from the toilet joins up with the drain pipe from the tub.You're going to need to have the pipe snaked.
The best method for replacing a toilet flange seal is to first turn off the water supply to the toilet and remove the toilet from the flange. Clean the area around the flange and remove the old seal. Install a new wax or rubber seal, making sure it is properly aligned with the drain pipe. Reattach the toilet to the flange and tighten the bolts securely. This will help prevent leaks and ensure a secure connection between the toilet and the drain pipe.
Usually toilet flange is glued down onto plastic drain pipe. There is a toilet flange that can be glued inside of plastic drain pipe also.
Who needs a toilet