Bus bars themselves don't usually fail. Failures normally occur at a connection point, and is usually caused by the bolt or screw becoming loose, or by corrosion. The resulting resistance causes the connection point to become hot, and eventually fail.
The most common method of detecting this condition is by infrared thermography. An infrared camera is used to find connections with elevated temperature.
Absolutely. You need the range ground to be fully connected back to the panel ground buss bar.
There are two temperature categories for copper buss bar. For a 30 degree C rise the sizes are 1/4" X 1" or 3/8" X 3/4". For a 50 degree C rise the size is 1/4" X 3/4". Both of these temperature categories will handle 400 amps.
In order for something to be shocked it must have a path to ground. If the bird is setting on a power line it is not grounded so therefore it does not get shocked. If the crow were to spread its wings to fly and get between two phases then it would be shocked because it would basically become a buss bar between two of the three phases.
To obtain the amp of the copper bus bar, multiply the width of the bus bar by the thickness of the bus bar to obtain the current carrying capacity of the bus bar.
ITS NOT TO COMPLICATED REALY, YOU NEED A HOLE BIG ENOUGH FOR GROUND WIRE GOING OUT TO PASS THROUGH THE BOX, IF IT IS FOR A BREAKER PANEL IT SHOULD HAVE AN ADAPTER THAT HAS THE INSERT THROUGH THE BOX WITH A LOCKING NUT AND A BUSHING ( PLASTIC ) THAT KEEPS THE CABLE FROM GETTING DAMAGED FROM COMING IN CONTACT WITH METAL BOX. THERE SHOULB BE A GROUNDING BUSS IN THE BOTTOM OR ONE OF THE SIDES THAT HAS THE ATTACHMENTS FOR THE GROUNDS FROM 1 TO WHO NOWS HOW MANY DEPENDING ON HOW MANY GROUNDS YOU WILL NEED.( ONE BIGGER GROUND WIRE COMING IN TO BUSS BAR, SEVERAL( DEPENDING) SMALLER WIRES COMING FORM THE FEEDS THROUGHOUT THE STRUCTURE. )ONCE YOU GET BUSS AND INCOMING GROUNDS, THE ONE THAT ATTACHES TO THE GROUND ROD AND THE WIRE ( BE SURE TO PUT THE ACCORN CLAMP ON BEFORE YOU PUT THE GROUND ROD INTO THE GROUND , IN CASE IT GETS MUSHROOMED DOWN FROM DRIVING IT INTO THE GROUND) USE WATER IN THE HOLE , RAISE THE GD. ROD UP AND DOWN KEEPING THE HOLE FAIRLY WET . IF IT IS JUST DIRT IT WILL GO IN REAL EASY, IF THERE IS ROCKS AND ETC. IN HOLE YOU WILL HAVE TO DRIVE IT IN. THE FURTHER GROUND ROD GOES IN THE BETTER. 10 FEET IS THE COMMON LENGTH FOR THE ROD TO GO INTO THE DIRT .ATTACH THE WIRE TO THE ROD WITH THE CLAMP YOU PUT ON PRIOR TOO AND YOU HAVE GOT IT.
Arcing is caused by a poor electrical connection. The breaker is not making good contact with the buss bar. Try replacing the breaker.
Generally, a bus or buss is a point at which which multiple circuits converge and are electrically common. This can be done through a buss bar intended solely for that purpose (as below) or any point in a system where power is distributed among multiple paths. A buss bar is a strip or bar of copper. brass, or aluminum that conducts electricity within a switchboard, distribution panel, substations, battery bank, or other electrical apparatus. Its main purpose is to conduct electricity, not to function as a structural member.
There are several busses in PC motherboards, but you probably mean the Front Side Buss. This is a set of parallel conductors that all of the data in a PC travels to and from the CPU by. It's called a buss, as in the old term "buss bar", because all of the peripherals in the PC connect to it in parallel. Each peripheral only read/writes to this buss when it is addressed by the CPU.
A 'bus bar' (not 'buss') is usually a strip of heavy-duty rectangular-section copper conductor, at line, neutral, or earth potential, to which a number of individual circuit conductors can be connected. It provides a common point of connection for several circuit conductors. The origin of the word, 'bus', comes from 'omnibus' -which means 'providing for many things at once'.
It depends on what happens because the product is faulty. If you are selling a computer that is faulty because the space bar sticks sometime, then that would be OK. BUT, if you were selling a computer that will explode killing everyone in a 100 yard radius, then this is not OK. Is the product dangerous? If not, then it should be OK to sell, as long as you tell the buyer what is wrong with it and don't try to defraud your buyer.
Yes. They have to pull power from each buss bar (2).
A buss bar essentially acts as a big, thick wire. It exists to distribute electrical power with little resistance and consequently little power loss.AnswerA 'bus bar' (not'buss' bar) is usually a strip of heavy-duty rectangular-section copper conductor, at line, neutral, or earth potential, to which a number of individual circuit conductors can be connected. It provides a common point of connection for several circuit conductors. The origin of the word, 'bus', comes from 'omnibus' -which means 'providing for many things at once'.Read more: What_is_a_buss_bar