You Don't. 440volt 3-phase is actually 480 volts, taking a single phase gives 277Volts single phase.
To get single phase 440 you would use one leg of three phase 440/760 three phase power.
You do not get 440 volts out of 220 volts. The 220 voltage is stepped up to 440 volt by utilizing a 220 to 440 volt step up transformer.
The single phase voltage in India is 230v when we check with the phase and the nutral single line
Let's get the terminology correct. A 'phase voltage' is measured across a phase, whereas a line voltage is measured between two lines. So there is no such thing as a 'phase to phase' voltage -it's a line to line voltage (hence the term 'line voltage').
single phase, double phase & three phase
You can not change it. 440 volt is by design. However you run it with 220 single phase supply, but it would run far lower power.
The difference between a single phase and a three phase motor is the amount of power conductors that feed the device. As to the other part of the question a three phase motor will not start or run on single phase. The phase angles on three phase are 120 degrees apart on a single phase system they are 180 degrees apart.
The single phase voltage in India is 230v when we check with the phase and the nutral single line
Let's get the terminology correct. A 'phase voltage' is measured across a phase, whereas a line voltage is measured between two lines. So there is no such thing as a 'phase to phase' voltage -it's a line to line voltage (hence the term 'line voltage').
In three-phase there are three live wires and a neutral. The voltage of a three-phase system is always quoted as the live-to-live voltage, and the voltage from one live wire to neutral is 57.7% of that. A 440 v 3-ph system has 254 volts between live and neutral. <<>> The question statement is not correct. Two legs from a three phase three wire 440 volt system will still be 440 but classed a single phase. On a three phase four wire system supply, the voltages will be determined by the following equation. 440/(square root of 3) 1.73 = 254 volts. The second single phase voltage attainable from this source connection is any one of the three phase legs to grounded neutral center point. This is known as a wye or star point connected voltage supply. To obtain a 220 volt single phase voltage, the three phase system would have to have a voltage of 220 x 1.73 = 380 volts.
It is 230V single phase and 440V in 3 phase system at 50 Hz.AnswerIf the single-phase voltage is 230 V, then the three-phase voltage must be 400 V, not 440 V. The line voltage is 1.732 times the phase voltage.
Yes, there is a difference between single phase and three phase circuits.
There is no such thing as a two phase instrument. There is only single phase and three phase. You can only have: single phase/ one pole single phase/ two pole three phase/ three pole
single phase, double phase & three phase
Any load that needs three legs from a three phase system can not be considered single phase. Single phase from a three phase system only needs a connection to two legs.
You can not change it. 440 volt is by design. However you run it with 220 single phase supply, but it would run far lower power.
No A intermediate switch can not be used to change three phase to single phase.
Single phase.
The difference between a single phase and a three phase motor is the amount of power conductors that feed the device. As to the other part of the question a three phase motor will not start or run on single phase. The phase angles on three phase are 120 degrees apart on a single phase system they are 180 degrees apart.