Best Answer

I'd say it wouldn't be -40 volt, but in fact 40 volt. I'm guessing you measured it with a multimeter and had your polarity (positive/negative) mixed up when you placed the leads on the telephone line.

--------------------------------------------------------------

The nominal voltage between tip and ring on the telephone line is 48 VDC (it is provided by a 24 cell lead acid battery in the central office) but this can be reduced by line drop by as much as 9 VDC depending on how far you are from the central office. Tip is connected to the positive side of the battery and ring is connected to the negative side of the battery. The tip and ring twisted pair is isolated from ground, so either can be used as your multimeter reference as long as you are aware of polarity so the reading of the multimeter will make sense.

User Avatar

Wiki User

7y ago
This answer is:
User Avatar
More answers
User Avatar

Wiki User

14y ago

The standard voltage for the telephone system is 48 volts DC. Ringing voltage is much higher, around 90 volts AC at a low frequency. When you place a load of about 600 ohms on the line, you are "off hook" or connected.

Telephone ringer voltage is 50.5 volts at standing and -50.5 volts at ringing

This answer is:
User Avatar

User Avatar

Anonymous

Lvl 1
3y ago

6 volts DC

This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: What is the voltage of telephone line?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Engineering

Why a lamp cannot run with the telephone line voltage?

A lamp can be run by power from a telephone line.


How do you convert 3 phase RMS line-line voltage to RMS line-neutral voltage on an unbalance system Basically how do you calculate using trig for all 3 phase?

The term, 'unbalanced system' refers to an unbalanced load. Under normal circumstances, an unbalanced load leads to unbalanced line currents. The line voltages are determined by the supply and remain symmetrical, even when the load is unbalanced. As your question refers to a 'line to neutral' voltage (i.e. a phase voltage), you must be referring to a star (wye) connected load, in which case the phase voltage (line to neutral voltage) is 0.577 (the reciprocal of the square-root of 3) times the line voltage (line to line voltage).


What is a line to line voltage?

In a 3 phase system, the voltage measured between any two phase is called line to line voltage.And the voltage measured between line to neutral is called phase to neutral (line to neutral) voltage.AnswerThere is no such thing as a 'phase-to-phase' or a 'phase-to-neutral' voltage. The correct terms are 'line-to-line' and 'line-to-neutral'.The voltage between any two line conductors is called a line voltage.In a three-phase, three-wire, system, the line voltage is numerically equal to the phase voltage.In a three-phase, four-wire, system, the voltage between any line conductor and the neutral conductor is called a phase voltage. The line voltage is 1.732 times larger than the phase voltage.


How match 2 phase line voltage between them?

To match 2 phase line voltage it has to be the same voltage.


What voltage should 208 3 phase leads read?

From line-to-line (any two of the three leads) voltage or 'line voltage', the voltage is 208 V. The line-to-neutral (one of the three leads and the neutral conductor), or 'phase voltage', is 120 V.

Related questions

Why a lamp cannot run with the telephone line voltage?

A lamp can be run by power from a telephone line.


What is the voltage of a telephone line?

48 VOLTS


Why telephone line has negative voltage?

A negative live voltage is used to prevent electroytic corrosion on the copper wires.


What is the voltage of telephone line in Pakistan ptcl?

it has 52volt dc off hook


A telephone-repair technician uses a meter to measure voltage on a phone line. This meter is an example of .?

it is hardware not software


How many volts can a landline telephone handle without blowing?

Since the ringer voltage across the twisted pair is 120 VAC RMS the telephone can definitely handle that. Given the fact that the telephone is also supposed to survive induced surges from nearby lightning strikes to the line the telephone should be able to handle over 1000 V common mode impulses (but I don't know the exact limit). No telephone is expected to survive a direct lightning strike to the line (which could be millions of volts). Note: common mode means the voltage is applied between the twisted pair lines (both at about the same voltage) and ground. If the survivable common mode voltage were to be applied across the twisted pair instead it would severely damage the telephone.


Is transmission voltage a phase to phase voltage or a phase to ground voltage?

Phase to Phase voltageCorrection to the above answer:There is no such thing as a 'phase-to-phase' or 'phase-to-ground' voltage. The correct terms are 'line-to-line' (or 'line voltage') and 'line-to-ground' (or 'phase voltage'). Transmission-line voltages are line-to-line (or 'line') voltages.


What is edge speed in electronics?

A voltage is applied to a signal line. The voltage of the line changes gradually from 0 to +V. The "edge speed" is the rate of change of voltage of the line. A voltage is applied to a signal line. The voltage of the line changes gradually from 0 to +V. The "edge speed" is the rate of change of voltage of the line.


What is the voltage required to activate a telephone answering unit connected to a telephone?

48 volts


What is a easy way to extend a telephone line?

You can use an in-line coupler to extend a telephone line.


How do you convert 3 phase RMS line-line voltage to RMS line-neutral voltage on an unbalance system Basically how do you calculate using trig for all 3 phase?

The term, 'unbalanced system' refers to an unbalanced load. Under normal circumstances, an unbalanced load leads to unbalanced line currents. The line voltages are determined by the supply and remain symmetrical, even when the load is unbalanced. As your question refers to a 'line to neutral' voltage (i.e. a phase voltage), you must be referring to a star (wye) connected load, in which case the phase voltage (line to neutral voltage) is 0.577 (the reciprocal of the square-root of 3) times the line voltage (line to line voltage).


Is 220V line voltage or phase voltage?

Phase, if you are referring to line, as power line from pole.