It's possible that you need to adjust the amount of air pressure in the pressure tank.check the tank with a tire pressure gauge.The pressure should be set to the installation specifications. If you have to reset the breaker the new well pump probably draws more current than the old pump and the feed is now undersized. Check the ratings of the pump. If the pump runs, the voltage is probably correct. Check the current rating of the pump. Look for a surge current rating, if one is marked. You want your breaker to be at least 5A more than the max current draw of the motor to prevent blowing the breaker on start-up. If you find the breaker is undersized, DO NOT JUST REPLACE THE BREAKER!!! The wiring is undersized, too! This requires a complete re-wire all the way up to the pump, which has the potential to be a big job. Tips: Look at the pump. If it is a 110/220V motor operationg on 110V you can move it up to 220V. Because the pump will now be only drawing half the current as before, so the existing wiring should be large enough. I wrote a nice how-to on how to switch a motor over to 220V in the electrical section of this site. Then all you need to do is replace the 110V breaker with a 220V breaker. Make sure the well pump is on a dedicated circuit before you try this, or else you will have some nice little fires when you turn the new breaker on. Also check the ratings on your pressure switch to make sure it can handle it. My general rule of thumb for wire sizes (These should be less than or equal to, but WikiAnswers erases text with equal signs.) <15A max - 14Ga <20A max - 12Ga <30A max - 10Ga <40A max - 8 Ga <50A max - 6 Ga If you need to run 8Ga or higher to a pump, man, that's a big pump. If you didn't understand everything I said above, or if you have any doubts, hire an electrician. If you get the wire sizing wrong on high power loads, or if you change the voltage or current without checking the ratings of all the fixtures on the line, you can (very) easily start a fire.

User Avatar

Wiki User

16y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: With a newer well system what would cause loss of water pressure which can be corrected by flipping the breaker switch?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

Can a 220 Volt well motor be added to a 200 amp box or does it need its own box?

The well pump breaker is installed in two slots in your breaker box. You then run the correct size cable for the amperage of the pump to the area where the pressure tank is located. install a breaker or disconnect on the wall near the pressure tank and then connect the low pressure switch to the disconnect. Connect the pump to the low pressure switch.


Which is easier to use a fuse or a breaker switch?

A breaker switch is easier to use.


What is a non auto circuit breaker?

A non-auto circuit breaker is a circuit breaker with the trip element removed. Basically, it is a modified circuit breaker that is now a disconnect switch (glorified disconnect switch).


What breaker will interchange with American Switch Company?

Replacement for American Switch single pole 15 amp circuit breaker


What circuit breaker will interchange with American Switch Company?

Replacement for American Switch single pole 15 amp circuit breaker


Can you get electrocuted if the switch is off but the breaker is on?

Yes you can. The proper wiring of a switch is to bring the hot wire to the top of the switch terminal and connect the load to the bottom of the switch. When the breaker is turned off it disconnects the voltage from the top of the switch and the switch is then safe to work on. By not turning the breaker off, the voltage is present at the top of the switch which could subject you to a nasty shock if you come into contact with it.


Is the circuit where is the is the circuit where is the circuit breaker for the?

The circuit breaker for the headlights is intergrated with the headlight switch.


Do i need to switch circuit breaker since i went from 115V well pump to 230V well pump it is also a higher HP pump but pressure is lower than before?

The 230v breaker is 2-pole, The 115v is only single-pole so YES you need a new breaker. DON'T use 2 single-pole breakers instead. The well pump will run to the pressure setting of the pressure switch controlling it, regardless of HP. The difference might be in the size of the pump in flow rating, I.E. a 1/2 HP pump rated at 10gpm @ 70 psi won't perform the same as a 3/4 HP pump rated at 20 gpm @ 50 psi. Check the pump curve and pressure switch setting. The pressure switch for the new pump will need both power leads connected to the switch (1 lead per contact set), not 1 wire as the 115v motor was.


Where is the headlight circuit breaker on a 1998 Crown Victoria?

the circuit breaker is built into the headlight switch.


How can you get off grid?

Switch your main breaker off.


Where can you find circuit breaker for headlamps on 1997 jimmy?

The circuit breaker for the headlights is built into the headlight switch.


Why did electricity along the line go out when switch was turned on?

Bad switch or a short and tripped the breaker.