MODELS:
1995 - 1998 (FJ) Avenger/Sebring/Talon
DISCUSSION:
The listed models are shipped from the factory with only one key FOB transmitter. If
a second FOB is added, it must be purchased through MOPAR and is not considered a warrantable item.
Whenever a second FOB is programmed, the original FOB must also be re-programmed. If the original FOB is not re-programmed with the second FOB, the original FOB will not function.
The following two procedures are available to program key FOB transmitters.
Programming Procedures With The DRB III(R).
1. Connect the scan tool to the vehicle and power it up.
2. Select scan tool stand alone mode, current model year diagnostics, then body.
3. The screen will ask if this is a 95-99 Avenger/Sebring/Talon, select yes.
4. Follow the directions and prompts on the scan tool screen as follows:
a. Close all doors, turn ignition key to off.
b. Turn ignition key to Accessory.
c. Turn ignition key to off, door locks will cycle once (in programming mode).
d. For each key FOB, press any button 3 times in a row to program code. When
programming is complete, the door locks will cycle once.
NOTE:
IF A SECOND KEY FOB REQUIRES PROGRAMMING, IT MUST BE PROGRAMMED WITHIN 1 MINUTE OF
THE FIRST FOB PROGRAMMING. PRESS ANY BUTTON ON THE SECOND FOB 3 TIMES TO PROGRAM
ITS CODE. WHEN PROGRAMMING IS COMPLETE, THE DOOR LOCKS WILL CYCLE ONCE.
5. The programming mode finishes after the following:
a. Programming of two key FOBS is completed.
b. One minute has passed since programming.
c. Scan tool is disconnected.
d. Ignition switch is turned on.
e. Any of the doors are opened.
Manual Programming Procedure (non scan tool)
1. Connect pin 1 of the 16-way data link connector to chassis ground or to pin 4 of
the 16-way data link connector.
2. Close all doors, turn ignition key to off.
3. Turn ignition key to Accessory.
4. Turn ignition key to off, door locks will cycle once (in programming mode).
5. For each key FOB, press any button 3 times in a row to program code. When
programming is complete, the door locks will cycle once.
NOTE:
IF A SECOND KEY FOB REQUIRES PROGRAMMING, IT MUST BE PROGRAMMED WITHIN 1 MINUTE OF
THE FIRST FOB PROGRAMMING. PRESS ANY BUTTON ON THE SECOND FOB 3 TIMES TO PROGRAM
ITS CODE. WHEN PROGRAMMING IS COMPLETE, THE DOOR LOCKS WILL CYCLE ONCE.
6. The programming mode finishes after the following:
a. Programming of two key FOBS is completed.
b. One minute has passed since programming.
c. Pin 1 of 16-way data link connector is removed from ground connection.
d. Ignition switch is turned on.
e. Any of the doors are opened.
You stick the key in the door and turn.
It can not be disabled. It is reset by unlocking as door with a key, or with the remote.
The alarm is reset by unlocking the doors with a key or the remote.The alarm is reset by unlocking the doors with a key or the remote.
The 1998 Chrysler Sebring has a timing belt.
Try turning the ignition on and off about 10 times until the door locks, lock and unlock, then lock with the remote done.
The factory alarm can not be disabled. It is reset by unlocking the car with the remote or with the key in the door.
No
No.
The 1998 Sebring OBD 2 port is under driver side dash next to center console
No the style on changed on the 2001 , the compatibility is 1996-2000
No.
Yes.