answersLogoWhite

0


Best Answer

ecg

User Avatar

Wiki User

10y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: Applications of random scan display system?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

Is raster scan displays same as bit-mapped displays?

raster scan display -based on television technology.where as random scan display based on hard copy devices.raster scan display cannot directly pass electron beam through the scan line..but random scan directed the beam toward the scan line.


What is random scan display in CRTcomputer?

In random scan display the electron beam is directed only to the part of the screen where the picture is to be drawn. Random Scan monitor draw one picture at a time therefore they are also known as vector display.refersh rate or random scan system depends on the number of times to be displayed. Picture definition is stored in an area of memory called refresh display file.


Where in use random scan?

plen plotter is most example of random scan display


What is the use of display file in random scan system?

Display File is a memory area which stores picture definition as a set of line drawing commands.Video controller interprets these commands and produces actual image on the screen.Display File in random scan system is comparable to frame buffer in raster scan system, on the basis of their functions.


How does random scan display works?

it blows up your computer. SORCE i have shrapnal in my eye


What are the applications of raster scan graphics?

Application of Raster scan display: Basically it is used in Plotters. and mainly more like....Printers,,,,


What are the relative advantages and disadvantages of random scan and raster scan display system?

Raster-scan system:-1)raster displays have less resolutio. 2)the lines producced are ziz-zag as the plotted values are discrete.3)high degree realism is achived in picture with the aid of advanced shading and hidden surface technique.4)decreasing memory costs have made raster systems popular.Random scan system:-1)random displays have high resolutions since the picture definition is stored as a set of line drawing commands and not as a set of intensity values. 2)smooth lines are produced as the electron beam directly follows the line path.3)realism is difficult to achieve.4)random-scan system's are generally costlier.


Compare the merits and demerits of raster and random scanning system?

Raster-scan system:-1)raster displays have less resolution.2)the lines produced are ziz-zag as the plotted values are discrete.3)high degree realism is achived in picture with the aid of advanced shading and hidden surface technique.4)decreasing memory costs have made raster systems popular.5)In this case, the electron beam is swept across the screen, one row at a time from top to bottom.6)Picture definition is stored in a memory area called the refresh buffer/frame buffer.7)Refreshing on raster scan displays is carried out at the rate of 60 to 80 frames/second. Random scan system:-1)random displays have high resolutions since the picture definition is stored as a set of line drawing commands and not as a set of intensity values.2)smooth lines are produced as the electron beam directly follows the line path.3)realism is difficult to achieve.4)random-scan system's are generally costlier.5)Here CRT has the electron beam directly only to the parts of the screen where a picture is to be drawn.6)Picture definition is stored as a set of line drawing commands in an area of memory referred to as refresh display file.7)Random scan systems are designed to draw all the component lines of a picture 30 to 60 times each second.


What is random scan and interlacing?

When operated as a random-scan display unit, a CRT has the electron beam directed only to the parts of the screen where a picture is to be drawn. Random-scan monitors draw a picture one line at a time and for this reason are also referred to as vector displays (or stroke-writing or calligraphic displays). The component lines of a picture can be drawn and refreshed by a random-scan system in any specified order (fig). A pen plotter operates in a similar way and is an example of a random-scan, hard-copy device. Refresh rate on a random-scan system depends on the number of lines to be displayed. Picture definition is now stored as a set of line-drawing commands in an area of memory referred to as the refresh display file. Sometimes the refresh display file is called the display list, display program, or simply the refresh buffer. To display a specified picture, the system cycles through the set of commands in the display file, drawing each component line in turn. After all line-drawing commands have been processed, the system cycles back to the first line command in the list. Random-scan displays are designed to draw all the component lines of a picture 30 to 60 times each second. High-quality vector systems are capable of handling approximately 100,000 "short" lines at this refresh rate. When a small set of lines is to be displayed, each refresh cycle is delayed to avoid refresh rates greater than 60 frames per second. Otherwise, faster refreshing of the set of lines could burn out the phosphor. Random-scan systems are designed for line-drawing applications and can-not display realistic shaded scenes. Since picture definition is stored as a Set of line-drawing instructions and not as a set of intensity values for all screen points, vector displays generally have higher resolution than raster systems. Also, vector displays produce smooth line drawings because the CRT beam directly follows the line path. A raster system, in contrast, produces jagged lines that are plotted as discrete point sets. jackson francis malugala computer engineer DSM institute of technology DAR ES SALAAM TANZANIA


Explain architecture of raster graphic system with display processor?

In random scan display, also called vector scan display,stroke writing or calligraphic.The electron beam directly draw the picture i.e. draw a picture one line at a time.Random scan monitor sketch the picture using vector line.Refresh rate on a random scan system depends on the number of lines to be displayed.Picture definition is now stored as a set of line drawing commands.In an area of memory referred to as the refresh display file is called the display list,display program or simply the Refresh Buffer.Random scan display systems are designed for line design applications and cannot display realistic shaded scene.Since,picture definition is stored as a set of lines drawing instructions and not as a set of intensity values for all screen pixels.Vector display generally have a higher resolutions than raster scan.Also vector display produce smooth line drawings.ADVANTAGES:1. Very high resolution, limited only by monitor.2.Easy animation, just draw at different positions.3.Required little memory.DISADVANTAGES:1.Requires intelligent electron beam i.e. processor controlled.2.Limited speed density before have flicker.3.Cannot draw a complex image.4.Limited color capability(very expansive).


Which display device is suited for cad system a a crt with vector referesh monitor b crt with raster scan monitor c plasma panel display d led display?

a


What are the difference between raster scan system and random scan system?

Raster-scan system:-1)raster displays have less resolution. 2)the lines produced are ziz-zag as the plotted values are discrete.3)high degree realism is achived in picture with the aid of advanced shading and hidden surface technique.4)decreasing memory costs have made raster systems popular.5)In this case, the electron beam is swept across the screen, one row at a time from top to bottom.6)Picture definition is stored in a memory area called the refresh buffer/frame buffer.7)Refreshing on raster scan displays is carried out at the rate of 60 to 80 frames/second.Random scan system:-1)random displays have high resolutions since the picture definition is stored as a set of line drawing commands and not as a set of intensity values. 2)smooth lines are produced as the electron beam directly follows the line path.3)realism is difficult to achieve.4)random-scan system's are generally costlier.5)Here CRT has the electron beam directly only to the parts of the screen where a picture is to be drawn.6)Picture definition is stored as a set of line drawing commands in an area of memory referred to as refresh display file.7)Random scan systems are designed to draw all the component lines of a picture 30 to 60 times each second.