answersLogoWhite

0


Best Answer

Hi,

Always interpoles are connected in series with armature.

N.V.B.V. Prasada Rao

User Avatar

Wiki User

12y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: Are the interpoles in a DC motor connected in series or in parallel with the armature?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Engineering

What happens if load of DC series motor is disconnected?

In D.C Shunt motor, the field winding is connected parallel with the armature winding.. If you remove the supply to armature winding, the motor will stop after some time.


Remedies for Armature reaction?

Since an armature is wound with coils of wire, a magnetic field is set up in the armature whenever a current flows in the coils. This field is at right angles to the generator field, and is called cross magnetization of the armature. The effect of the armature field is to distort the generator field and shift the neutral plane. The neutral plane is the position where the armature windings are moving parallel to the magnetic flux lines. This effect is known as armature reaction and is proportional to the current flowing in the armature coils. The brushes of a generator must be set in the neutral plane; that is, they must contact segments of the commutator that are connected to armature coils having no induced emf. If the brushes were contacting commutator segments outside the neutral plane, they would short-circuit "live" coils and cause arcing and loss of power. Armature reaction causes the neutral plane to shift in the direction of rotation, and if the brushes are in the neutral plane at no load, that is, when no armature current is flowing, they will not be in the neutral plane when armature current is flowing. For this reason it is desirable to incorporate a corrective system into the generator design. These are two principal methods by which the effect of armature reaction is overcome. The first method is to shift the position of the brushes so that they are in the neutral plane when the generator is producing its normal load current. in the other method, special field poles, called interpoles, are installed in the generator to counteract the effect of armature reaction. The brush-setting method is satisfactory in installations in which the generator operates under a fairly constant load. If the load varies to a marked degree, the neutral plane will shift proportionately, and the brushes will not be in the correct position at all times. The brush-setting method is the most common means of correcting for armature reaction in small generators (those producing approximately 1000 W or less). Larger generators require the use of interpoles.


Are devices of home connected in series or in parallel?

Home devices are connected in parallel and not in series.


How do you determine which windings are field on a series DC motor?

Both the supply wires that enter a series motor is the field windings the field is split in two and is connected at the split to the brushes that is connected to the commentator of the armature, so the current pass thru the first half of the field then thru the armature and then thru the other half of the field. With a parallel DC motor the two fields is in series and the two wires is connected to the brushes so is the supply.


Which circuit the ammeter connected in parallel?

An ammeter is always connected in series and a vlotmeter in parallel

Related questions

What is the use of interpoles in dc machine?

Interpoles are similar to the main field poles and located on the yoke between the main field poles. They have windings in series with the armature winding. Interpoles have the function of reducing the armature reaction effect in the commutating zone. They eliminate the need to shift the brush assembly.


Basic principle of commutator motor meter?

It is based dynamometer principle with ironless motor with a wound armature having a commutator. The two coils are connected in series with supply and armature coil is connected in parallel to it.


What happens if load of DC series motor is disconnected?

In D.C Shunt motor, the field winding is connected parallel with the armature winding.. If you remove the supply to armature winding, the motor will stop after some time.


How are the series and shunt field windings of the compound wound dc motor connected relative to the armature?

series field in series with the armature shunt in parallel with the voltage supply the shut field increases the strength of the magnetic field with heavy loads to reverse the motors direction the fields remain the same you swap the armature leads


Remedies for Armature reaction?

Since an armature is wound with coils of wire, a magnetic field is set up in the armature whenever a current flows in the coils. This field is at right angles to the generator field, and is called cross magnetization of the armature. The effect of the armature field is to distort the generator field and shift the neutral plane. The neutral plane is the position where the armature windings are moving parallel to the magnetic flux lines. This effect is known as armature reaction and is proportional to the current flowing in the armature coils. The brushes of a generator must be set in the neutral plane; that is, they must contact segments of the commutator that are connected to armature coils having no induced emf. If the brushes were contacting commutator segments outside the neutral plane, they would short-circuit "live" coils and cause arcing and loss of power. Armature reaction causes the neutral plane to shift in the direction of rotation, and if the brushes are in the neutral plane at no load, that is, when no armature current is flowing, they will not be in the neutral plane when armature current is flowing. For this reason it is desirable to incorporate a corrective system into the generator design. These are two principal methods by which the effect of armature reaction is overcome. The first method is to shift the position of the brushes so that they are in the neutral plane when the generator is producing its normal load current. in the other method, special field poles, called interpoles, are installed in the generator to counteract the effect of armature reaction. The brush-setting method is satisfactory in installations in which the generator operates under a fairly constant load. If the load varies to a marked degree, the neutral plane will shift proportionately, and the brushes will not be in the correct position at all times. The brush-setting method is the most common means of correcting for armature reaction in small generators (those producing approximately 1000 W or less). Larger generators require the use of interpoles.


Are devices of home connected in series or in parallel?

Home devices are connected in parallel and not in series.


Is it connected in series or parallel?

series


How do you determine which windings are field on a series DC motor?

Both the supply wires that enter a series motor is the field windings the field is split in two and is connected at the split to the brushes that is connected to the commentator of the armature, so the current pass thru the first half of the field then thru the armature and then thru the other half of the field. With a parallel DC motor the two fields is in series and the two wires is connected to the brushes so is the supply.


What is DC shunt motor?

A shunt DC motor connects the armature and field windings in parallel or shunt with a common D.C. power source. This type of motor has good speed regulation even as the load varies, but does not have the starting torque of a series DC motor


Which home appliances are connected in parallel and which in series?

All home appliances are connected in parallel.


Which circuit the ammeter connected in parallel?

An ammeter is always connected in series and a vlotmeter in parallel


Is a ammeter connected in series or in parallel with the circuit under test?

An ammeter is connected in series. A voltmeter is connected in parallel. ammeter should always be connected in series instead of parallel becoz it is a low resistance device and we know that resistance is inversly proportional to current so more current will pass through it and if it is connected in parallel than it may get damaged