answersLogoWhite

0

No. Not safe to do so. The distances between contacts may not be sufficient.

User Avatar

Wiki User

13y ago

What else can I help you with?

Related Questions

Your medical machine says 110240 can you use it in a 240 volt system in cuba?

If you mean 110/240, yes, but there may be a hidden switch to switch it to 240 volt mode. Check the manual.


What are the differences between 120 volt and 240 volt electrical systems?

The main difference between 120 volt and 240 volt electrical systems is the amount of voltage they provide. A 120 volt system is commonly used for household appliances and lighting, while a 240 volt system is typically used for larger appliances like stoves and dryers. The higher voltage of a 240 volt system allows for more power to be delivered, making it suitable for heavier electrical loads.


Can you use a 12 volt dimmer switch for a 240 volt ceiling rose?

No, the voltage rating of the switch is too low.


How do you install a switch for a 240 volt motor?

Use a DPST - A two pole switch.


Does 240 volt have a neutral wire?

Yes <<>> In North America, a three wire 120/240 volt system uses a neutral wire. For 240 volts two "hot" wires are used with no neutral.


When is white wire hot?

In residential wiring, if it is used as a switch leg or in 3 wire 240 volt circuits.


Where do you attach the neutral in a 240 volt switch?

Unless the switch has a pilot light on it there is need for a neutral connection to the switch.


How many watts can a 10amp 240 volt switch carry?

A 10 amp switch connected to a 240 volt circuit can carry up to 2400 watts (10 amps x 240 volts = 2400 watts). It's important to ensure that the switch is rated for the anticipated load to prevent overheating or failure.


Can you run a double phase motor on home 220 volt system?

If you mean a dual voltage motor 120/240 then yes these will operate on a 240 volt home distribution system.


Do they make a inline switch to cut power on a 240 circuit?

In North America, the use of a two pole single throw switch is used for this purpose. The reason that a two pole switch is used instead of a single pole switch is that code requires that both legs to the 240 volt load has to be broken so as to isolate the load completely from the supply voltage. If a single pole switch was used in this situation one leg of the 240 volt supply would still be "hot" to ground. Someone that is inexperienced with the system could get a nasty shock by just using the switch to isolate the circuit when working on it instead of using the supply breaker to isolate the circuit. In the UK it is a different scenario as the load across the 240 supply returns to a grounded neutral. In this case just a single pole single throw switch will isolate the circuit.


Is France 110 volt or 220 volt?

France uses 220-240 volts for their electrical system.


How do you work out what power a 240 volt switch uses at 1amp?

Power = Amperes x Voltage