Best Answer

I greatly hope someone who has had personal experience with this comes to answer your question, but until they do I'm giving you my guesses.

I think the problem will be the physical connection. I don't think you can physically connect your 50 amp male connector to the park's 30 amp female. That said, 50 amp service provides 220 volts. It's my understanding the the other 110 leg (that creates the 220) is only used to power a second air conditioner and also your 220 electric range/oven if you have one. If you don't have an 220 kitchen and don't need the second AC you can run your RV off a 30 amp service.

To do this I think you will have to have someone who knows what they're doing wire a 50 amp to 30 amp adapter cable. I guess I'm kind of surprised 50 amp RVs don't come with a 30 amp adapter cable and instructions on how it can be used, but I don't own an RV so all this could be wrong.

User Avatar

Wiki User

11y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: Does a 50 amp motor home have to have 50 amps?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

What is the gauge for 6 Amp?

50 amps


How many amps per leg can you pull on a 50 amp 3 phase connector?

50 amps.


What size circuit breaker is used for a 10000 watt single phase cooler with 240 volts?

The equation for amperage is Amps = Watts/Volts = 10000/240 = 41.6 amps. It is not stated if this is a motor load or not. If it is a motor load then the feeder has to be rated at 125% x 41.6 = 52 amp wire. Also if it is a motor load then the breaker will have to be 250% x 41.6 = 104 amps. A 100 amp breaker will work and still be within the electrical code ruling. Otherwise for 41.6 amps a 50 amp breaker will be sufficient.


What is the average amp rating for a double oven?

50 amps


Can you put 10-3 UF cable on a 50 amp circuit breaker?

A #10 copper conductor with an insulation rating of 90 degrees C is rated at 30 amps. The only time that a breaker larger that the load maximum capacity can used is in motor connections. A breaker can be used sized at 250% of the motor's full load amperage. In this case a 50 amp breaker can be used on a #10 conductor if the motor's full load amps falls within the amperage's of 20 - 22 amps.


What can you run off a 50 Amp breaker?

Anything that does not pull over 50 amps.


It is safe to use 8-3 wire on a 50 amp breaker?

No, it is not safe to use a #8 conductor on a 50 amp breaker. A #8 conductor is only rated at 45 amps capacity. By connecting it to a 50 amp breaker, which would trip at 50 amps on an overload, would overload the conductor by an extra 5 amps. This would be a conflict against the electrical code.


What is decimal value for 50 milliamps on 1 amp scale?

It is 0.050 amps.


How many amps does a 100 amp service supply?

A 100 amp service will supply your electrical current needs UP TO 100 amps.When doing load calculations on a 100 amp panel it can only be loaded up to 80 amps.


DC carrying capacity of 50 sq mm copper cable?

140 amp


What size wire for a 3 phase 50 amp compressor?

The North American electrical code states that a conductor for a motor must be rated at 125% of the motor's full load amperage. 125% x 50 = 63 amps. A #6 copper conductor with an insulation factor of 75 or 90 degrees C is rated at 65 amps respectively.


Will your spa work with a 40 amp breaker even if it says 50 amp on the plate?

No, because if you switch a 50-amp load on, it will blow a 40-amp circuit breaker if the load exceeds 40 amps, which is likely.