answersLogoWhite

0


Best Answer

On the U shaped blade for 120 volt 15 amp plug.

<><><>

As always, if you are in doubt about what to do, the best advice anyone should give you is to call a licensed electrician to advise what work is needed.

: If you do this work yourself, always turn off the power

at the breaker box/fuse panel BEFORE you attempt to do any work AND

always use an electrician's test meter having metal-tipped probes

(not a simple proximity voltage indicator)

to insure the circuit is, in fact, de-energized. IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS JOB

SAFELY AND COMPETENTLY

REFER THIS WORK TO QUALIFIED PROFESSIONALS.

User Avatar

Wiki User

14y ago
This answer is:
User Avatar
More answers
User Avatar

Wiki User

15y ago

No, the plug on the dryer should be a 4 pin plug. Likewise, in the wall there should be a 4 pin 30 amp receptacle

This answer is:
User Avatar

User Avatar

Wiki User

13y ago

Yes.

This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: Does the ground go with the neutral when installing 3 prong dryer outlet?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Natural Sciences

How do you put on a four prong outlet on a roper electric dryer?

Black &amp; Red are hot, and White is neutral. If it has no place to connect neutral connect neutral to ground.


What is the difference between a 4 prong dryer outlet and a 4 prong stove outlet?

The four blade dryer plug brings a separate ground wire from the machine to the electrical grounding system. The three blade dryer plug depended on the neutral wire of the plug to make this connection.


How do you add an electrical hookup for a dryer?

If there isn't a power outlet in reach of the unit you have two options. Call an electrician to install an outlet or call a carpenter to redesign your kitchen so that there is one near (basically move the dryer). Extension cables are not recommended for permanent use in kitchens.


When I disconnect the neutral wire from sub panel still have juice in the gfi outlet When i connect the hair dryer to the gfi without the neutral it works and the light in the bathroom turns on?

You have some serious wiring problems, for sure. My first guess is that your grounding conductor and neutral are touching somewhere and your ground is acting as the neutral when the neutral is disconnected. The light coming on when the hair dryer is used is another mystery. You need to hire a competent electrician to trouble shoot these problems.


Why 4 wires for dryer?

The dryer is a 240v dryer so two of the wires are your hot wires, or the ones with power on them. One is your ground wire. And the forth is your neutral.

Related questions

How do you put on a four prong outlet on a roper electric dryer?

Black &amp; Red are hot, and White is neutral. If it has no place to connect neutral connect neutral to ground.


What is the difference between a 4 prong dryer outlet and a 4 prong stove outlet?

The four blade dryer plug brings a separate ground wire from the machine to the electrical grounding system. The three blade dryer plug depended on the neutral wire of the plug to make this connection.


What do the letters stand for on a 4 prong plug?

On a 240 volt outlet, such as a dryer outlet: G is Ground, W is Neutral, X and Y are the two Hot legs.


How do you add an electrical hookup for a dryer?

If there isn't a power outlet in reach of the unit you have two options. Call an electrician to install an outlet or call a carpenter to redesign your kitchen so that there is one near (basically move the dryer). Extension cables are not recommended for permanent use in kitchens.


When wiring 4 prong plug for 220 has W X G and Y what goes into the X and Y?

On a 240 volt outlet, such as a dryer outlet: G is Ground, W is Neutral, X and Y are the two Hot legs.


When I disconnect the neutral wire from sub panel still have juice in the gfi outlet When i connect the hair dryer to the gfi without the neutral it works and the light in the bathroom turns on?

You have some serious wiring problems, for sure. My first guess is that your grounding conductor and neutral are touching somewhere and your ground is acting as the neutral when the neutral is disconnected. The light coming on when the hair dryer is used is another mystery. You need to hire a competent electrician to trouble shoot these problems.


Why 4 wires for dryer?

The dryer is a 240v dryer so two of the wires are your hot wires, or the ones with power on them. One is your ground wire. And the forth is your neutral.


Is it necessary to connect the ground wire to a 4-prong 240V outlet - I am switching a 3-outlet to a 4-prong outlet for my new dryer but the ground wire is cut off so I can't connect it?

Only if you wanted to fry your hair.for God sake(and yours)buy a new cord to hook up your dryer


Can you plug a four prong dryer into a three prong outlet or is there an adapter you should use?

=== ====== === Old practice [accepted by National Electrical Code requirements] allowed the frame [chassis] of dryer to be bonded to the neutral conductor by a link to provide ground. New NEC requirements call for separation of neutral and ground paths. In a new house, or if you install a new cable to feed the dryer, you would be required to run a wire with an insulated neutral and a ground wire [10/3 with ground - 4 wires]There are 2 possibilities:One is that there is actually a 4-wire cable feeding that outlet, in which case you CAN change the dryer outlet to a 4 wire type - you just have to put the right wires on the right terminals and make sure the ground is connected in the panel. [Even though we only used 3 wire outlets, most electricians I know had run 10/3 with a ground for dryers in case the unit got hard-wired, which used to be allowed.]The second possible answer is that you are allowed [unless your township or city doesn't allow it - always check with them first] to establish a ground-to-neutral link inside the dryer unit for the chassis ground and replace the 4-wire plug with a 3-wire plug. [See NEC Article 250.140] Answer Some dryers also have devices (such as lights and the timer) that run on 120 volts. These need a neutral that is separate from the protective ground.I got a new dryer yesterday... the plug on it has four prongs and my old one has three prongs. So can the old three prong plug be taken off my old dryer and be put onto the new dryer? I notice my old three prong plug is not color coded like the one on the new one. Also when I took the old dryer off and unplugged it, a green ground wire was still fixed to it (the old dryer), so how would I ground the new dryer being that it only has three prongs? Thanks in advance. === ===


Do you need a neutral when running a BLK Red and ground from a panel directly to a 240V 4800W 20A heater outlet?

No. The black is 220, the red is 220, and the ground serves as the neutral. the last answer "no" is correct but the reason is not. the ground is still a ground. the red is 110v and the black is 110v. together they are 220v. the neutral or (common) is for a 110v return. for example a stove or a dryer will have 2 hots a common and a ground because they use 220v and 110v. 220v to power the heating elements and 110 for the controls, light bulbs or the outlet on a stove. A construction heater only uses 220v and only requires the two hots and the ground for safety.


Where do you ground the extra wire when plugging a 4 prong wire into a three prong outlet for a dryer at?

It may be a 220 Dryer, and you will need a new outlet installed. There should be no extra wires when connecting the Power cord to the plug


Why are you getting 123V at your dryer outlet?

You are probably measuring between the one leg of the 240 volts and the neutral or the ground pin connection. Take the measurement from the two outside blade holes on the receptacle. There the reading should be 230 to 240 volts. Between either of the outside blade holes and the neutral or ground you should read around 120 volts.