answersLogoWhite

0

YOU thread or braze copper pipe Copper tubling you solder, braze, flaire, compression ring, mechincal joints

User Avatar

Wiki User

17y ago

What else can I help you with?

Related Questions

You want to replace old lead pipe connected to cast iron sewer pipe with copper How do you connect the copper pipe to the old lead pipe or to the cast iron pipe?

When I have to connect copper to lead "D" I usually solder the copper to the lead or wipe a lead joint depending on the diameter To connect copper to cast iron ,.... If there is a hub I caulk the copper directly into the CI with oakum and poured lead (molten) OR one can solder / braze a female adapter fitting and screw the copper into a CI female fitting


Can a 2.5 galvanized dielectric union be used to connect black pipe to copper pipe?

Yes


Can you connect chromed steel pipe directly to copper or do you need a brass fitting between?

In order to connect a chromed steel pipe to a copper pipe, you will need a brass fitting. These two pipes will not fit into each other otherwise.


What is a sweat inlet?

It is probably referring to the type of fitting. A fitting that is soldered to a copper pipe. It is called sweating when you use solder and a torch to connect copper pipe together or attach fittings to copper pipe.


Do you need pipe dope to connect brass pipe to copper pipe?

NO but you will need some type of sealent OR braze or soldering


Is it okay to connect copper pipe to brass to galvanized to brass and back to copper or will it cause a reaction that will corrode the pipes?

If you do connect copper pipe to galvanized pipe, you will need a dielectric coupling or else the galvanized pipe will corrode. Same with connecting galvanized pipe to brass fittings. Brass is an alloy that contains copper and therefore the same electrolytic properties will exist unless a dielectric coupling is used. Hope that helps you out.


What diameter copper pipe should you use to connect with 1 galvanized radiator pipe I've been advised to reduce to a three-quarter inch copper pipe.?

If you had been advised why ask again?


How do you connect copper propane pipe and shutoff valve?

To connect a copper propane pipe to a shutoff valve, you will need to use a threaded fitting that matches the size and type of the pipe and valve. Apply pipe dope or Teflon tape to the threads before connecting them. Tighten the fitting securely using a wrench or pliers to create a leak-proof connection.


How do you connect Copper pipe to PVC?

You can often find a modern connector such as Sharkbite or Qwest fitting to do this.


Can you connect brass to copper pipe?

Yes, you can either solder them or fit mechanical (threaded) fittings.


How do you connect flex pipe to a copper tubing?

You use a compression fitting or something like a Sharkbite.


Lead pipe connected to copper pipe?

Easiest way to connect lead to copper /brass is a wiped joint consisting 40 - 60 solder alloy as this gives a longer pasty range