Basic Gas Heater Diagram;

Millivolt, Dual Thermostat Previous

Green arrows indicate electrical current flow, as created by the heated pilot generator.

1. Main Gas Line

2. Main Gas Supply Valve 3. Gas Control Valve

3a. Control/Pilot Knob

3b. Pilot Valve

3c. Pilot Light gas supply line.

3d. TP Voltage Input.

3e. TP/TH Voltage Input;

(Common to TP and TH).

3f. TH Voltage Input. 4. Main Gas Valve Output

5. Pilot Light/Generator

Assembly.

5a. Thermopile/Pilot Voltage

Generator.

5b. Pilot Light Burner Assy.

5c. Insulated Pilot Voltage

wiring.

(red and white wires).

5d. Spark Rod *

5e. Spark Rod Ceramic

Insulator.*

5f. High Tension Wiring.*

5g. Piezo Spark Generator. * 6. High Limit Temperature Sensor.

7. Water Pressure Switch. 8. Pool Temp/Thermostat 1.

8a. Thermostat Sensor 1. 9. Spa Temp/Thermostat 2.*

9a. Thermostat Sensor 2.* 10. Thermostat Selector Switch.*

11. Flame Sensor.*

12. Burner Output Manifold.

13. Fireman Connection.* * Not on all systems . Concepts of Operation. Millivolt style gas heaters control the flow of gas with the main gas valve, item 3 above. This valve is powered with a very low voltage supply source, called the pilot generator. The original name for this device is called a 'thermopile', and is simply an encased, twisted pair of wires made from dissimilar metals, such as copper and zinc. When this type of twisted wiring is heated, it generates a small voltage. The gas heater uses this voltage to operate 2 separate electro-magnetically operated valves inside of it. These precision devices are designed to open and allow the flow of gas, with as little as 250 millivolts applied to them, however, the valves are most effective with approximately 450 millivolts of power. Most pilot generators will generate as much as .850 volts (850 millivolts), when new. Over time, this voltage level will deteriorate, and the valve's operation may become erratic, and sometimes just stop working altogether. At that point, if the voltage output of the pilot generator is less than .250 volts underload from the gas valve, then it's time to replace the generator. The Pilot Valve

The first valve is called the pilot valve. When you initially ignite a pilot light flame, you must hold down the rotating valve select switch for a short while to get the pilot to stay lit. What is happening, is that while you are holding down the red knob, you are bypassing the electrically activated pilot valve, and allowing the thermopile/pilot generator to heat up sufficiently, to generate enough voltage to keep the pilot valve open. Once this happens, the valve is opened, and then you can release the control knob. This provides a critical safe operation feature, in that if the pilot light ever goes off, the pilot generator cools off, and subsequently, without enough voltage to keep it open, the pilot valve will turn itself off, preventing flooding of gas in the heater or the room where it is located. Main Gas Valve

The main gas valve, simply supplies gas to the burner manifold. Also operated by the pilot generator, the voltage/current flow from the generator goes through a number of devices in a daisy chain fashion. If any of these devices break the circuit, the main gas valve will shut down, stopping the heater from operating. These devices almost always incorporate a thermostat, on/off switch, high temperature limit switches located in the water manifolds, pressure switch, and a flame switch which is usually located near the front opening of the burner tray compartment. What's a Fireman Switch?

Sometimes, there is also a connection block usually colored red, called the 'fireman' switch connection. What this is normally used for, is for a connection to a remote thermostat, and to a micro-switch contained inside the pool/spa timer. In the latter, let's say that you've got a pool or spa pump set to turn on at 4:00, and turn off at 8:00. The position of the microswitch on the timer, shuts down the heater operation approximately 15 minutes prior to pump shut down, to give the heater time to cool down with the water continuing to run through it. On some heaters, without this switch, it is possible to cause problems with the heat exchanger, and/or heater manifolds due to excess heat build up after the pump has shut down. The millivolt heater is quite an efficient system, and has been proven for many many years, and as such, is still being produced by many manufacturers. Service Precautions

Never under any circumstances, disassemble a gas valve and attempt to repair it. These are extremely precision devices, and the slightest error in reassembly, including scratching the milled surfaces or warping the control rods, could result in a disaster that could burn your house down... or worse. Always replace the gas valve as a complete assembly.

User Avatar

Wiki User

15y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: How does outdoor gas heater safety valve work?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

Why wont the heater work in 95 camaro?

bypass valve not opening


Why no heat 2004 Acura RL?

Does the fan work? if not, check fuses. if does work, check coolant level first. Next, check heater valve in engine compartment, on fire wall, has ~ 1 inch hoses connected between the engine and to the heater core inside the passenger side. Have someone turn temperature knob inside car and observe cable on Heater Valve is moving. (Can be simple as the screw on top of heater valve loose or cable maybe stuck). Heater valve can be stuck closed. Check hose gets hot between valve and heater core.


If a pilot light goes out in a gas water heater does the gas keep running?

No because water heaters have a safety valves and when the pilot light goes out the safety valve shuts off the gas


How much does a patio heater cost at Menards?

At Menards you can buy an outdoor patio heater at http://www.menards.com/main/outdoor/patio-furniture-benches/87-outdoor-patio-heater/p-1651682.htm for $149.99. A patio heater varies in length of life depending on the power source. If you have a propane tank, you can run out if used often in a week. Outdoor heaters are less effective than indoor heaters because outdoor heaters have to work harder to heat the whole patio (cold weather will undo any work already done) while indoor heaters don't have to worry about varying temperatures.


Where is the heater control valve in a 2004 Buick Regal LS?

How to fix heater in Buick there is cool air ,fan is work .but no warm air


Acuator valve replacement for heater 2005 Chevy venture?

my heater fan in front of my 2004 chevy venture van wont work


Heater doesnt work but cold air blows out?

Low coolant? Bad thermostat? Heater core plugged,restricted or airbound? Heater control cable or valve not working?


What would cause the rear AC not to cool on a 2004 Chateau front does work?

Most likely it's the heater control valve. If the heater control valve leaks a little it can allow a small amount of heated engine coolant to circulate through the rear heater core.


What would cause the heater in a 1997 Taurus not to work even after you drained the radiator changed thermostat and added new coolant?

the heater core could be pluged or the heater control valve is stuck closed


Why won't your heater work?

Not plugged in? Gas valve shut? Oil ran out? Thermostat /aquastat not calling for heat?


Safety checking of the childrens indoor and outdoor environment before and during work activities?

Safety checking of the children's indoor and outdoor environment before and during work activities is very critical. This ensures that children have a safe playing environment and also checks all the equipment to see if they have been damaged after playing.


Can propane lines freeze to an inside stove?

Yes it will work. But if you turn the valve open to fast there is a safety mechanism inside the valve and the propane will not come out. You will need to open the valve slowly for the tank to work.