Q: How much voltage can be plugged into a rooftop unit with a GFCI outlet?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Engineering

What happen wen dc source and ac source conected together?

Depends if they are matched in phase and amplitude. Had a case recently where a house was miswired. There was an outlet that was connected to two breakers. I was trying to trace down a problem with a GFCI continually tripping. The clue was that as I turned off breakers one at a time, the power never went off at the input to the GFCI. When I removed the extra feed (It was in a different outlet box) the problem was fixed. It only affected the GFCI and the other things on the circuit worked. If was obviously a code violation and a bad implementation, but it "worked" in some sense.


Can you replace an ungrounded circuit breaker with a GFCI circuit breaker?

Yes but it's redundant and may cause unnecessary "tripping" of the circuit. The GFCI circuit breaker is intended to protect an entire receptacle circuit whereas a GFCI receptacle is designed to protect only that receptacle and any which are provided power from its load side. (downstream)


Which electrical protective device is designed to detect a difference in current location in circuit wires?

A) Outlet plug B) Ground-Fault Circuit Interrupter (GFCI) C) Electricity Read Monitor D) Current Path Detector


How does a ground fault circuit interrupter shuts down a circuit?

A ground fault circuit breaker detects leakage current between the hot wire coming off the breaker and the neutral/ground since the neutral is bonded to the ground in the panel, if it senses a current of 6 milliamps or more it will trip. Note: no sharing of the neutral for a circuit on a ground fault breaker If a few milliamps from the hot (black) wire do not return on the neutral (white) wire, then a GFCI assumes that current it traveling harmfully elsewhere through your body. So it disconnects. A GFCI can monitor 15,000 milliamps. But if only 5 go missing, then a GFCI trips.


Why does your gfci keep tripping after 15 minutesI suspect the circulating motor in my spa.?

The GFCI is sensing stray electricity. Usually, there is no GFCI connected to the pump motor. The GFCI devices would be associated with the air blower, or the lights. If it is the circuit breaker, then there may be a problem with the circulation pump or the circuit breaker itself. A qualified electrician will be able to locate and correct the electrical problem. A pool repair tech may be able to do the same and also correct the problem if it is the motor. Ken

Related questions

What happens if you trip a GFCI repeatedly on purpose?

Every time you trip the GFCI, the power to the device plugged into it will lose its supply voltage.


Could you show me an electrical drawing of a circuit with GFCI protecting a switch?

GFCI's are not used to protect a switch they are used to protect an outlet where something is plugged in.


Why does the reset button on a wall outlet pop out when something is plugged into it?

Assume this is a ground fault circuit interrupter (GFCI) outlet. The GFCI looks for current that is flowing to ground, in a manner that could result in electrical shock to a user. The appliance that is being plugged in could be defective, the wiring connected to the load side of the GFCI may be incorrect, or the GFCI outlet could be defective. Try using another appliance. If the GFCI holds, the first appliance is most likely the cause.


Getting no power from gfci outlet line?

A GFCI outlet has a TEST and RESET switch. Press reset and see if it fixes problem. If reset won't stay in that means that a ground fault condition is present and may be on another outlet that is fed from the tripped GFCI. If this isn't the problem check the main breaker feeding the GFCI and ensure it isn't tripped. If none of this works the GFCI itself may be bad. If you have a Volt Meter you can remove the outlet from the wall receptacle and make sure there is voltage present. You can also see if there is a branch circuit connected. To troubleshoot you can disconnect the branch circuit and then try reset. If you have voltage on input and GFCI won't reset with branch circuits removed, replace the GFCI.


Why does a newly installed GFCI outlet show open ground on the tester?

Ground wire is loose or disconnected somewhere in that circuit.


Do you need a gfci outlet if you have a gfci breaker?

Not if the GFCI breaker is supplying the circuit you are wanting to put the GFCI receptacle into.


How do you wire a pump for a fountain?

what is the type of pump three phase or single phase


Do all electrical outlets in a garage need to be GFCI?

Yes, but you can feed multiple outlets from one GFCI outlet. Make the first outlet fed in the cicuit a GFCI. Search for GFCI outlet with Google, etc. and I'm sure you will find an explanantion of how. Most GFCI's come with instructions also.


Do you wire a gfci outlet differently?

No, except that you insert the wires into the holes on the back of the outlet. The power in connects to the LINE side of the outlet and power out connects to the LOAD side of the outlet. This is clearly marked on the back of the outlet. This will not only protect the outlet with the GFCI installed but all outlets receiving their power from that GFCI. If you do not want to protect the outlets receiving power from the outlet then connect that outgoing wire to the LINE side also. But know that only the outlet with the GFCI will be protected and all other outlets will not be GFCI protected.


Can you use a GFCI plug into a GFCI outlet?

Yes you can. Lots of blow dryers have GFCI protection built in.


What happens when you plug a GFCI protected extension cord into an outlet that is GFCI protected?

In a word NO, that will not cause either GFCI to trip. The correct term is GFCI (Ground Fault Circuit Interrupter)


How do you wire an outdoor timer into a GFCI outlet?

I assume you are hard wiring it and not plugging it in. The power coming into the GFCI outlet connects to the line side of the GFCI outlet. If you want the outdoor timer protected by the GFCI then connect the wire going to the timer to the load side of the outlet. If you do not want the timer protected then connect it to the line side. On the back of the GFCI if you look closely you will see Line & Load marked on the back.