answersLogoWhite

0


Best Answer

yes, the pressure is directly related to the effective force acting on the fluid body, so from the pressure differential you can compute the effective force on a small mass of fluid in the orifice, which can then be translated into a flux integral, which can be solved for Volume/time.

User Avatar

Wiki User

13y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: Is there an equation that addresses how pressure psi affects flow cfm through a fixed orifice?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

What is nozzle pressure?

Pressure build up due to restricted orifice.


Difference between an orifice plate and a restriction orifice?

An orifice plate is a plat eused to measure flow. Pressure sensors are placed upstream and downstream of the the plate and hepressure differential is used with Bernoullis Equation t compute flow (including some experimental factors). A retriction plate is similar to an orifice plate but is much thicker. It is used to drop pressure upstream of a system. The convergence, throttlnig through thick section and divergece works the fluid and reduces total energy (transformed in firction, heat etc). This leads to an overall pressure reduction.


Why is the orifice plate called a variable head flow meter?

Because it relies on the back pressure through a known orifice which its differential pressure across the plate relates to flow.


What is the difference between Restriction Orifice and Flow orifice or please explain the symbols RO Restriction orifice and FO Flow Orifice?

A restriction orifice (RO) is used to limit the flow through the pipe to a set flow by choking the flow at its sonic velocity. A flow orifice (FO) is usually used to determine the flow through the pipe from the pressure drop over the plate. There a normally two pressure taps (one on each side of the plate) and a pressure transmitter which determines the pressure drop over the plate. A formula is then used to convert this pressure drop to a flowrate for the specific fluid passing through the orifice. A FO usually has a temperature element to determine the gas temperature for use is the formula.


Where is the ac low pressure side switch on 4.3 Blazer?

It's not a switch. The high pressure runs from the compressor outlet to the orifice tube inlet, and the low pressure side runs from the orifice tube outlet to the compressor inlet.


What is the calibration curve of orifice meter?

The calibration curve for an orifice meter will depend on the size of the orifice, the size of the pipe and the pressure loss over the meter. Typical calibration curves have pressure (or head) loss on the vertical (y) axis and flow rate on the horizontal (x) axis.


Can an orifice in a steam line act as a steam pressure reducing valve?

Yes. But it is limited in control by the orifice size, pressure applied and piping diameter. In other words it is "fixed". An example would be the metering device in a refrigerant circuit, specifically an orifice or capillary tube. The same physics apply.


Where is the orifice filter located on a 98 escort zx2?

in the high pressure line


What causes high pressure on low side if no refrigerant added on a 1999 cadillac?

sounds like there is no orifice tube in it. orifice tube should be located just before it enters the firewall at end of high pressure line


Where is the orifice tube on a 1999 Chevrolet Suburban?

Most orifice tubes are placed in the high pressure line to the evaporator at the fire wall connection. You will have to empty the freon from the system to replace the orifice tube which is not very expensive (the tube, that is).


What is orifice meter?

Orifice meter is a flow measuring device used for calculating the pressure drop,flow rate and behaviour of the fluid moving through the pipe.


What are the applications of circular orifice?

An orifice plate is a device used to measure the rate of fluid flow. It uses the same principle as a venture nozzle namely Bernoulli’s principle which says that there is a relationship between the pressure of the fluid and the velocity of the fluid. When the velocity increases, the pressure decreases and vice versa. An orifice plate is basically a thin plate with a hole In the middle. It is usualy placed in a pipe in which fluid flows. As fluid flows through the pipe, It has K.a certain velocity an a certain pressure. When the fluid reaches the orifice plate, with the hole in the middle of the fluid is forced to converge to go through the small hole, the point of maximum converyence actually occurs shortly downstream of the physical orifice, at the so called vena contracta point as it does so the velocity and the pressure changes. Beyond the vena contracta the fluid expands and the velocity and pressure change once again. By measuring the difference in fluid pressure, between the normal pipe section and at the vena contracta, the volume metric and mass flow rates can be obtained from Bernoulli’s equation. By assuming steady-state, compressible, laminar flow in a horizontal pipe negligible frictional losses, Bernoulli’s equation reduces to an equation relating the conversation of energy at two points in the fluid flow or V1=Q/A1 & V2=Q/A2. Slowing for Q and introducing the beta factor β=d2/d1 as well as coefficient of the discharge Cd. And finally introducing the expansion γ to account the compressibility of gasses and the meter coefficient C which is defind as to obtain the final equation for the volumetric flow of the fluid upstream of the orifice. It we consider about the value of coefficient of velocity (Cv). It may be accurated due to the practical errors. In that case we had to control the over flow rate actually. The top level of a adjustable over flow pipe was decreased gradually. So we had to hold it during the experiment to make the head constant. There may be some errors in measuring time, also we calculated to value of the Q using the equation Q=V/t, the Q2=V2/t2. If there is any error in time. If will increase when “t” become “t2”. So then there may be errors in values of Cd of the first part of experiment. In practically orifice is used in channels, pipelines, canal or hydro power stations to act as a water controller. Mostly those orifice are used to in reservoirs and pipelines. It may be used for measuring the rate of flow out of the reservoirs or through a pipelines, orifice may be in the wall or in bottom of the reservoir or tank . The orifice equation describes the rate of flow of liquid through an orifice. The equation can be represented as: Q = Cd A\sqrt{2gh} where Q = flow (cubic metres per second) C(d) = coefficient of discharge A = area of orifice (square metres) g = acceleration from gravity (9.81 m/s) h = head acting on the centreline (m) For a circular orifice, the equation becomes: Q = Cd (1/4 \pi D^2)\sqrt{2gh} Typical values for the coefficient of discharge are: Sharp orifice: 0.62 Tube: 0.80