Best Answer

That's because the neutral is a grounded conductor.

Answer

The line (not 'phase'!) conductor has a potential of 230 V (Europe) or 120 V (North America) with respect to the neutral, which is earthed (grounded) at the supply panel.

As you are more than likely 'earthed' (or 'grounded') by virtue of standing on it, this means that if you come into contact with a line conductor you will experience a potential difference of 230 V (or 120 V) between your point of contact with that line conductor and your point of contact with the earth, and you will receive a shock.

However, as the neutral conductor is already at, or close to, earth potential, should you come into contact with the neutral conductor, you will experience no (or very little) potential difference, and receive no shock.

User Avatar

Wiki User

12y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: Shock on a phase wire not on a neutral wire?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

When an ac bulb glows the phase wire gives a shock when touched by hand but the neutral wire doesn't?

== ==


Why is it always connected in the phase or line wire to the switch and not the neutral wire?

because its much safer to switch the hot wire then the neutral wire because if you are working on a light fixture for example and the switch is off if you ground yourself out to the neutral you become the load or return. a neutral shock can me more dangerous at times


If you touch both neutral and live wire together do you get shocked?

The neutral is supposed to be grounded on all installations, single phase and three phase, according to the electrical code so no you will not get a shock if you touch the neutral wire. If the neutral wire is not grounded you might in some circumstances get a little tickle of voltage.


Why neutral wire doesn't give electric shock?

The neutral wire doesn't give an electric shock because it is the same potential as ground. That being said if you come in contact with the "hot" wire and the neutral or ground wire, you become the load and will receive a substantial shock.


Why dont phase and neutral exchange?

Phase wires are "hot" wires and are the current-carrying conductors. (These are the wires that will shock you if you touch them.). The neutral wire is basically there to carry the electricity back to the source. It is not normally considered current-carrying. If you switch these two wires, you might energize the metal of equipment, causing a dangerous shock hazard.


Phase wire and neutral wire joined?

Never join them, that is a dead short.


Which is the Hot wire and which is the Neutral wire if the wires you see are a Black a Red and a Yellow wire?

Black red and yellow is three-phase. there is no neutral.


When does a motor not need a neutral wire?

If the motor is operated from a three phase three wire distribution system the motor will not need a neutral wire.


When upsizing wire for voltage drop how much smaller can the neutral wire be the next phase conductor?

The neutral wire should be the same size as your conducters


Is a neutral wire in a 4 wire service?

Yes, it is referred to as three phase four wire service.


How do you reduce neutral to earth voltage in three phase system?

It is done by connecting the neutral to earth at the transformer that produces the three-phase supply. If the three phase wire supply equal currents, there is no current in the neutral wire and its whole length stays at earth potential, but if there is current in the neutral it produces a small voltage on the neutral at places away from the transformer.


Is there a neutral conductor in a 3 phase 4 wire wye system?

no