Three phase allows power to be transmitted efficiently using three live wires. The voltages in the wires reach the peak of the AC cycle in turn, which allows each wire to act as the return wire for the other two, provided the currents in the wires are equal.
In some cases the load currents in the three live wires are unequal, so the system is described as unbalanced, and in this case a 4th wire is added as a neutral. If the system happens to be balanced, the current in the neutral is zero.
The 4-wire system allows single-phase loads to be connected between one live wire and neutral, and this type of supply is widely used throughout Europe to provide power to groups of houses. Over a sufficiently large number of houses the currents in the three phases are reasonably equal.
A "three-phase system" is a polyphase system having three phases. The term "polyphase system" just means a system having multiple phases. If it is used by itself, "a polyphase system" doesn't mean "a three-phase system".
3 phase system has more power than a single phase system
A two-phase system is archaic and you are unlikely to find it in use anywhere these days, so it is mainly of historical interest. A two-phase, three-wire system, consists of two phase voltages, displaced from each other by 90 electrical degrees, and a phase voltage which is 1.414 x phase voltage.A three-phase system consists of three phase voltages which are displaced from each other by 120 electrical degrees. In the case of a three-phase, three-wire, system, the line voltages are numerically equal to the phase voltages; in the case of a three-phase, four-wire, system, the line voltages are 1.732 x phase voltage.
A two-phase a.c. system is an archaic system, in which two phase voltages are generated 90 electrical degrees apart. It has nothing whatsoever to do with the US 'split phase' system that supplies North American homes. A two-phase system can be a four-wire system, or a three-wire system, and was useful because, unlike a single-phase system, it could create naturally rotating magnetic fields in induction motors. It has long been superseded by the three-phase system.
The number of Volts in a residential service drop in the US is either 120V 2 Wire, 120V-208V Network, or 120-240V 3 Wire. A 120-208V Network service is not single phase, but its 120V portion is.
3 Phase system is for industrial use and 1 phase is for house hold application
By having a transformer with 3 phase input and single phase out put
The formula for calculating the phase of a signal in a communication system is phase arctan(imaginary part / real part).
This is a rubbish questionTwo single phase transformers can be combined together to make a three phase system. It does not become a two phase system. Look up information of an open delta wired distribution system to see how they are tied together.See related links below.
A 3-phase 3-wire system provides a single-phase supply between any two wires. On a 3-phase 4-wire system with one line out but the neutral intact, the system is described as a faulty 3-phase system but it would allow a 3-phase motor to start, but not run properly. True 2-phase systems with the voltages in quadrature (90 degrees or one quarter cycle apart) were used in the 19th century but not since then because 3-phase was found to be better.
A balanced three phase system is where the currents into the loads placed on all three phases of the service are reasonably close to each other in amperage.Another opinionA 'balanced' three-phase system describes a three-phase load in which each phase current is identical in both magnitude and phase. If the phase currents are only 'reasonably close', then the load is not balanced.
In a three phase power system, each phase is separated from the others by 120 degrees.