armature reaction means when load is added to the armature then current is passed through armature conductors then in armature creates flux. It is demagnetize and cross magnetize the main field flux. in other ward it is effect of armature field on main field.
Armature
200ma is .200 amps or .2 amps
Amps = Watts / Volts Amps = 130000 / 480 Amps = 270.83
Amps is short for ampere, a unit for current.
resistance of the armature is more related to the current going thru it 250v Dc 5hp motor 20 a 12ohms 1/2hp 2 amps 120 ohms the speed will be related to the number of poles
armature reactant means loss in armature associated with inductive properties of the coil, while armature reaction include losses due to magnetizing component of current flowing through armature.
V Curve- Excitation vs Armature currentV curve is the graph showing the relation of armature current as a function of field current in synchronous machines. The purpose of the curve is to show the variation in the magnitude of the armature current as the excitation voltage of the machine is varied.Inverted V Curve- Excitation vs Power FactorThe synchronous motor "V Curves" shown above illustrate the effect of excitation (field amps) on the armature (stator) amps and on system power factor. There are separate "V" Curves for No-Load and Full-Load and sometimes the motor manufacturer publishes curves for 25%, 50%, and 75% load. Note that the Armature Amperage and Power Factor "V" Curves are actually inverted "V's".Assume it is desired to determine the field excitation which will produce unity power factor operation at full motor load. Project across from the unity power factor (100%) operating point on the Y-Axis to the peak of the inverted Power Factor "V" Curve (blue line). From this intersection, project down (red line) from the full-load unity power factor (100%) operating point to determine the required field current on the X-Axis.In this example the required DC field current is shown to be just over 10 amps. Note at unity power factor operation the armature (stator) full-load amps is at the minimum value.Increasing the field amps above the value required for unity power factor operation will cause the machine to run with a leading power factor, while field weakening caused the motor power factor to become lagging. When the motor runs either leading or lagging, the armature (stator) amps increases above the unity power factor value.
24 volt armature is accept balancing cut
It does have armature resistance.
armature reaction means when load is added to the armature then current is passed through armature conductors then in armature creates flux. It is demagnetize and cross magnetize the main field flux. in other ward it is effect of armature field on main field.
Armature reaction is the interaction between the magnetic flux produced by armature current and that of the main magnetic field in an electric motor or generator.
Armature reaction is the effect of armature flux on the flux generated by the fied windings.Cross magnetisation and Demagnetising are its consequences.
this is wer the armature conductors ar being mounted,therefor it helps the flexibility of armature conductors.
no
Armature current is the current flowing in a motor's armature. The "armature" is another name for the coil (or coils) of wire which are on the motor's "rotor", which is the part that rotates inside its stator. (The "stator" is the fixed, non-rotating part of the motor.)
Because the armature (or rotor) has no external connection. The currents that produce torque from the rotor are induced by the magnetic field in the machine, so there is no commutator, no brushes and no armature reaction.