this is wer the armature conductors ar being mounted,therefor it helps the flexibility of armature conductors.
1:The strenght of the main magnetic Field. Determined by the strenght of the field magnets in a permanent magnet machine, or by the number of turns of wire on the field coils and the current through the coils in a wound field machine.2: The number of armature conductors connected in series, which cut the main magnetic field. Determined by the number of turns on armature coils and weather the armature is lap or wave wound, which determines the number of armature conductors connected in series.3: The speed at which the armature conductors cut the main magnetic field. The faster the armature cuts the magnetic Field, the higher will be the value of the voltage generated in the machine
The pole tip which is met first during rotation by armature conductors is known as leading pole tip
It does have armature resistance.
Armature reaction is the effect of armature flux on the flux generated by the fied windings.Cross magnetisation and Demagnetising are its consequences.
this is wer the armature conductors ar being mounted,therefor it helps the flexibility of armature conductors.
coil span or coil pitch is defind as the distance mesured in terms of armature slots(or armature conductors) between two sides of a coil.
armature reaction means when load is added to the armature then current is passed through armature conductors then in armature creates flux. It is demagnetize and cross magnetize the main field flux. in other ward it is effect of armature field on main field.
1:The strenght of the main magnetic Field. Determined by the strenght of the field magnets in a permanent magnet machine, or by the number of turns of wire on the field coils and the current through the coils in a wound field machine.2: The number of armature conductors connected in series, which cut the main magnetic field. Determined by the number of turns on armature coils and weather the armature is lap or wave wound, which determines the number of armature conductors connected in series.3: The speed at which the armature conductors cut the main magnetic field. The faster the armature cuts the magnetic Field, the higher will be the value of the voltage generated in the machine
What effect has the number of armature paths upon the current-carrying ability of a generator?
The pole tip which is met first during rotation by armature conductors is known as leading pole tip
The winding function of an electric motor is a description of how the number of conductors in the windings around the motor changes with position.
ARMATURE REACTION in DC MachineAll current-carrying conductors produce magnetic fields. The magnetic field produced by current in the armature of a dc generator affects the flux pattern and distorts the main field. This distortion causes a shift in the neutral plane, which affects commutation. This change in the neutral plane and the reaction of the magnetic field is called armature reaction.
1) PRINCIPLE:Whenever a conductor cuts magnetic flux, dynamically induced emf is produced in it. ( Faraday's Laws of Electromagnetic Induction ). This emf causes a current to flow if the conductor circuit is closed.2 ) OPERATION:Field winding produces magnetic field in D.C. generator. Armature is coupled to the prime mover. Prime mover produces torque so the armature rotates. The armature cuts the magnetic field so the emf is induced in the armature. When load is connected to the armature, electric current flows from the armature conductors, through load and back to the armature conductors. Now, as current flows through the armature and it is in the magnetic field, torque is produced due to it. (This torque is called back torque). If the load on the generator is increased, the back torque increases so the torque of the prime mover also increases and the input power to the prime mover increases. In this way, the generator converts mechanical energy into electrical energy.It should be observed that the emf induced in D.C. generator, is A.C. ( so the emf induced in the armature is alternating in nature. ). Then with the help of commutator, it is converted into D.C. Rings and brushes are used to take the emf outside.
Reactance is a result of inductance. Inductance is a result of a changing magnetic flux cutting a wire or let say, a coil, or, a result of a moving conductor cutting a magnetic field. DC motors are inductors i.e they have reactance. This happen as soon as the armature starts rotating. The armature is moving in the magnetic field of the field windings thus an emf is induced in them as the armature conductors start cutting the field. It's this emf that limits the armature current once the motor is in motion.
armature reactant means loss in armature associated with inductive properties of the coil, while armature reaction include losses due to magnetizing component of current flowing through armature.
24 volt armature is accept balancing cut