Best Answer

if we r talking about the power that is generated in powerhouses( i.e, source is not a D.C battery), one of the two terminals that comes out of the dynamo(of generator) is grounded near the generating plant itself. so theoretically speaking, ground and neutral are at same potential. so voltage diff between them would be 0.

but practically, ground is a term given to terminal that connects body of electrical appliance at home or industry directly into earth. this is done to prevent electrocution of any person handling it, just in case the body of appliance comes into contact with a live wire within the instrument(may be due to faulty wiring or normal wear and tear) and with probably defective neutral contact. Even in case of such a happening, if there is proper grounding, the voltage diff between them is 0.

User Avatar

Wiki User

13y ago
This answer is:
User Avatar
More answers
User Avatar

Wiki User

13y ago

it should be 0V , but as per our earth pit maintaining that voltage will be varied even also not exceed 5V

This answer is:
User Avatar

User Avatar

Wiki User

13y ago

the highest ive seen is132,000 v

the load is delta and there is a huge resistor from neutral to ground for ground fault detction

insulators are about12' tall

This answer is:
User Avatar

User Avatar

Wiki User

16y ago

1.8 v to 2.0v 1.8 to 2.0 v

This answer is:
User Avatar

User Avatar

Wiki User

11y ago

The voltage should be zero.

This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: What is the voltage difference between the neutral and the ground?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Engineering

Why we don't get shock if we touch neutral wire..we need two wires to close circuit pH and n when circuit closes current will flow around the circuit and one wire gets shocked other not why?

We don't get shocked when we touch neutral and ground because neutral is grounded back at the distribution panel, so the effective voltage between neutral and ground is very low. It won't be zero, because there is current flowing on neutral, causing a voltage difference between the load and the distribution panel, but it is low enough, assuming there is no malfunction, to not cause a shock.In the case of touching hot and neutral, or hot and ground, you will get shocked because there is line voltage between hot and neutral, and because neutral and ground are connected together, there is also line voltage between hot and ground.Note, however, that connecting a load between hot and ground is a violation of the code and the intent of the design, because ground is not rated to carry current except in short term fault conditions - you must always connect a load between hot and neutral, or between hot and hot, as the case may be.


Why neutral ground voltage is 120v sometime 0v?

There should be no voltage on the neutral wire to ground. This is a serious situation. Call a qualified electrician to check this out.


Could the neutral point voltage be like phase voltage?

Yes,when the neutral potential is at ground potential i.e., 0v.


Does voltage on ground mean open ground?

Voltage on ground can mean an open ground. It can also mean (high) current on ground, due to a ground fault such as reversed neutral and ground.


If in the three phase connection phase to phase voltage is 400v what will be the phase neutral voltage?

The formula to use is, phase voltage /1.73 = phase to neutral (ground) voltage.CommentThere is no such thing as a 'phase to phase', or 'phase to neutral' voltage. The correct terms are 'line to line' and 'line to neutral'. So the above answer should read: line voltage/1.73= line to neutral voltage = phase voltage.

Related questions

Could a neutral wire be powered?

There should be zero voltage between neutral and ground.


Difference between ground and neutral?

As i know,neutral is the return path of current & ground is for any leakage current


Why we don't get shock if we touch neutral wire..we need two wires to close circuit pH and n when circuit closes current will flow around the circuit and one wire gets shocked other not why?

We don't get shocked when we touch neutral and ground because neutral is grounded back at the distribution panel, so the effective voltage between neutral and ground is very low. It won't be zero, because there is current flowing on neutral, causing a voltage difference between the load and the distribution panel, but it is low enough, assuming there is no malfunction, to not cause a shock.In the case of touching hot and neutral, or hot and ground, you will get shocked because there is line voltage between hot and neutral, and because neutral and ground are connected together, there is also line voltage between hot and ground.Note, however, that connecting a load between hot and ground is a violation of the code and the intent of the design, because ground is not rated to carry current except in short term fault conditions - you must always connect a load between hot and neutral, or between hot and hot, as the case may be.


What are the differences between voltage and potential difference?

Voltage is the potential difference to the ground. By convention, ground potential is zero volt.The above answer is incorrect. 'Voltage', by definition, is potential difference. It has nothing to do with being measured with respect to ground -in fact potential difference (voltage) cannot be measured with respect to anything.


What is a ground fault?

difference in current between hot and neutral conductors


Why Hot and neutral are both hot?

You'll have to explain your problem better.If HOT black and Neutral White in your house wiring are both hot then Neutral is NOT bounded to ground in main panel and neutral could be floating. There should be no voltage between Neutral and Ground (Bare wire in panel). By code if there are multiple panels Ground is only bonded to Neutral in th emain entry panel. I have seen cases where this bonding was not done. At your main panel check voltage between neutral and ground. It should be zero.


Why neutral ground voltage is 120v sometime 0v?

There should be no voltage on the neutral wire to ground. This is a serious situation. Call a qualified electrician to check this out.


Why is it that when you touch the neutral in a box that is not connect to the panel cause the test light to come when touching the power wire?

It shouldn't. The open end of a non connected neutral should have the same potential as the voltage feeding the circuit. The only time a voltage will show is when the return neutral is tested with a meter to the neutral bar or the ground return bar. It will then show what the supply voltage to the connected load is. Once this neutral is connected to the neutral bar there will be no voltage shown across the test meter between the neutral and the neutral bar or the ground bar.


Should there be power from common to ground in wall socket?

120 volt wall outlets. Their could me a small voltage between neutral and ground,up to around 1.5 volts. What you are measuring is the voltage drop on the system at that point in the system. You see the neutral and the ground are at the same level some where up stream (service panel). The neutral is under the same load as the phase conductor, and the neutral will drop voltage same as the phase. This is in fact the way I measure voltage drop, (neutral to ground.) However don't get fooled by high imped. meter, They have a way of ghosting a voltage. Or floating high, You get a reading but the voltage is really not their.


How does an electric utility ground electricity delivered to your home?

Electricity is delivered to homes through transformers. The center of the transformer output winding is connected to ground. This center tap is then connected to the home power panel as the neutral lead. The voltage between the grounded neutral and either of the "hot" legs is half the voltage between the legs. In the US and Canada, the full voltage between the legs is 240V and between either leg and neutral is 120V.


What is the reasonable voltage between Neutral?

Between Neutral and Ground should be zero volts. Between Neutral and Hot should be 110 to 120 V in the USA, within the European Union it should be 230 V ± 6%.


Why no electric shock from neutral line?

There is normally no voltage on the neutral line because the neutral line is grounded. However, and this is always important, do not assume that neutral is grounded, nor that there is not an elevated voltage on neutral or ground due to a possible ground fault.