copper losses Comment: Advantages: Their operation is silent They have a high efficiency They are relatively safe Disadvantages Expensive Copper losses and hysteress losses

User Avatar

Wiki User

12y ago

What else can I help you with?

Continue Learning about Electrical Engineering

How do you connect Wye connection to open delta connection?

Dont mess with transformers if u dont know how to read a wiring diagram It is easy if u know your relation to each of the phases and neutral and ground


Is a step up transformer a Ynd or a Dyn?

Whether a transformer is 'step up' or 'step down' has nothing to do with the way its windings are connected, so it could be wye-delta or delta-wye.


What is the difference between Y or Wye and Delta 3 phase power?

The transformer connection. Transformers can be connected in Wye (One side of each winding connected to the phase wire and the other connected to neutral or ground) or Delta (the polarity of each winding connected to the nonpolarity of another winding to form a triangle).There are different problems that arise as a result of being connected wye vs. delta or vice versa, and multiple fixes or partial fixes to address these.Alternative Answer'Wye' (also known as 'star') and 'delta' (also known as 'mesh') are two methods (there are others!) of connecting the three phase windings of alternators, transformers, and loads such as motors). A wye connection is generally a four-wire system, comprising three line conductors and a neutral conductor, whereas a deltaconnection is a three-wire system, comprising three line conductors. For a perfectly-balanced load (e.g. a three-phase motor), a wye-connected system can dispense with the neutral conductor. In wye-connected systems, the line voltage (line-to-line) is 1.732 times larger than the phase voltage (line-to-neutral). In a delta-connected system the line voltage is exactly the same as the phase voltage (line-to-line in both cases).


Should a star-delta motor be supplied wye or delta power?

A star-delta motor should be supplied star-delta.Wye is simply another name for star. Star-delta motors use a star or wye configuration to start, and a delta configuration to run. This reduces the voltage on the windings during the high current starting time.


Delta - Wye Transformation of Resistance Network?

first you need to touch yourself

Related Questions

What is the difference between an open delta and an open wye connection?

An open delta connection is a delta connection with one phase removed, but still supplied with three line conductors. An open wye is a wye connection with one phase removed, supplying a three line conductors and a neutral conductor. An open-delta/open-wye is a method of providing a reduced-load three-phase supply using just two single-phase transformers, rather than the preferred method of using three single-phase transformers.


Can you bank three single phase transformers in a delta to grounded wye with one transformer having a different impedance?

yes


How do you find angular displacement of transformer?

Angular displacement (sometimes called phase displacement) applies to three-phase transformers, whether a single three-phase transformer, or three single-phase transformers connected as three phase transformer bank. It is, to a three-phase transformer what additive/subtractive polarities are to a single-phase transformer.Angular displacement is one of a number of conditions that must be the same before two three-phase transformers (or transformer banks) are paralleled.'Angular displacement' is the angle by which the secondary line-to-line voltage lags the primary line-to-line voltage.Angular displacements for common connections are as follows:delta/delta transformers have an angular displacement of 0o or 180owye/wye transformers have an angular displacement of 0o or 180odelta/wye transformers have an angular displacement of 30o or 210owye/delta transformers have an angular displacement of 30o or 210oSo, for example, it is impossible to parallel a delta/delta or wye/wye transformer with a delta/wye or wye/delta transformer, as their angular displacements are different.Determining the angular displacement of a particular transformer configuration (wye-delta, etc.) can be done by drawing the phasor diagram for the complete transformer as follows:draw the primary phase voltagesdraw the primary line voltagesdraw the secondary phase voltagesdraw the secondary line voltagesmeasure the (angular displacement) between a secondary line voltage and its corresponding primary line voltage


How do you change 3 1phase transformer in to 3 phase?

Three-phase transformation can be obtained using two Transformers, by connecting them in what is known as an 'open delta' connection.


What is Dy transformer step up or step down?

Theoretically, a delta-wye transformer can step up or step down. In Europe, tertiary distribution transformers are step-down delta-wye transformers, so that the secondary side offers a three-phase, four-wire, system offering 400 V line-to-line and 230 V line-to-neutral.


What connection is the higher ampere between delta and wye?

For the same load, delta provides higher current than wye, or star.Wye voltage is 1 / 1.732, or 0.577 that of delta. (1.732 is the square root of 3.) This gives a power of 0.333 for wye, as opposed to delta. (0.5772 = 0.333)This is why (no pun intended) we use wye-delta starters on large motors - it allows them to come up to speed at 1/3 power, before switching to full power on delta.


Why vector group is required?

There are various ways in which you can connect a three-phase transformer's primary and secondary windings, or in which you can connect three single-phase transformers to create a three-phase transformer bank. For example: wye-wye, wye-delta, delta-delta, delta-wye, etc.For each connection, there is a natural phase shift between the primary and secondary line voltages. This is called the angular displacement (or 'phase displacement') of the transformer connection.If you wish to parallel two three-phase transformers, or two three-phase transformer banks, then their angular displacements must be the same (there are also other requirements not relevant to this answer).A vector group is a method of specifying a three-phase transformer (or transformer bank) method of connection and its angular displacement. Transformer connections from the same group can be paralleled. Those in different groups cannot


How can you terminate a 3 wire wye motor to a 3 phase delta connection?

To terminate a 3 wire wye motor to a 3 phase delta connection you need a 3 phase transformer to convert from delta to wye. Do not lift the common neutral connections inside the motor and rewire for delta, because the voltages will be wrong.


How do you connect Wye connection to open delta connection?

Dont mess with transformers if u dont know how to read a wiring diagram It is easy if u know your relation to each of the phases and neutral and ground


Is a step up transformer a Ynd or a Dyn?

Whether a transformer is 'step up' or 'step down' has nothing to do with the way its windings are connected, so it could be wye-delta or delta-wye.


What is wye-delta motor control?

It is a type of starter that allows a motor to be started across the line by starting the motor with a reduced inrush current. The motor is started in a wye configuration until it gets up to speed and then a timer drops the wye contactor out a draws the delta configured contactor in. The motor then operates in a delta wired configuration.


What is the difference between Y or Wye and Delta 3 phase power?

The transformer connection. Transformers can be connected in Wye (One side of each winding connected to the phase wire and the other connected to neutral or ground) or Delta (the polarity of each winding connected to the nonpolarity of another winding to form a triangle).There are different problems that arise as a result of being connected wye vs. delta or vice versa, and multiple fixes or partial fixes to address these.Alternative Answer'Wye' (also known as 'star') and 'delta' (also known as 'mesh') are two methods (there are others!) of connecting the three phase windings of alternators, transformers, and loads such as motors). A wye connection is generally a four-wire system, comprising three line conductors and a neutral conductor, whereas a deltaconnection is a three-wire system, comprising three line conductors. For a perfectly-balanced load (e.g. a three-phase motor), a wye-connected system can dispense with the neutral conductor. In wye-connected systems, the line voltage (line-to-line) is 1.732 times larger than the phase voltage (line-to-neutral). In a delta-connected system the line voltage is exactly the same as the phase voltage (line-to-line in both cases).