Q: Delta - Wye Transformation of Resistance Network?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Electrical Engineering

Is a step up transformer a Ynd or a Dyn?

Whether a transformer is 'step up' or 'step down' has nothing to do with the way its windings are connected, so it could be wye-delta or delta-wye.


Should a star-delta motor be supplied wye or delta power?

A star-delta motor should be supplied star-delta.Wye is simply another name for star. Star-delta motors use a star or wye configuration to start, and a delta configuration to run. This reduces the voltage on the windings during the high current starting time.


What size of electric motor that requires wye delta starter?

10 hp and above motor power rating....


What is the difference between Y or Wye and Delta 3 phase power?

The transformer connection. Transformers can be connected in Wye (One side of each winding connected to the phase wire and the other connected to neutral or ground) or Delta (the polarity of each winding connected to the nonpolarity of another winding to form a triangle).There are different problems that arise as a result of being connected wye vs. delta or vice versa, and multiple fixes or partial fixes to address these.Alternative Answer'Wye' (also known as 'star') and 'delta' (also known as 'mesh') are two methods (there are others!) of connecting the three phase windings of alternators, transformers, and loads such as motors). A wye connection is generally a four-wire system, comprising three line conductors and a neutral conductor, whereas a deltaconnection is a three-wire system, comprising three line conductors. For a perfectly-balanced load (e.g. a three-phase motor), a wye-connected system can dispense with the neutral conductor. In wye-connected systems, the line voltage (line-to-line) is 1.732 times larger than the phase voltage (line-to-neutral). In a delta-connected system the line voltage is exactly the same as the phase voltage (line-to-line in both cases).


Where do you ground a delta delta transformer?

In a delta-delta transformer, none of the actual conductors are grounded, directly or indirectly. You do, however, always ground the casing. This is protective earth ground, or PE ground, as opposed to neutral, which is grounded at the distribution panel, but which is a current carrying conductor. PE ground is not a current carrying conductor - it is a safety ground. Some texts use the term grounded conductor to refer to neutral, and grounding conductor to refer to PE ground. Simplest designation is neutral and ground. In summary, for a delta-delta transformer, there is no neutral, but there is always a ground. There is always a ground in any circuit, even when there is a neutral, and, except in a few special cases, those are two different connections.

Related questions

How do you convert Pi-network to T-network?

Any pi network can be transformed to an equivalent T network. This is also known as the Wye-Delta transformation, which is the terminology used in power distribution and electrical engineering. The pi is equivalent to the Delta and the T is equivalent to the Wye (or Star) form. Pi NetworkT Network The impedances of the pi network (Za, Zb, and Zc) can be found from the impedances of the T network with the following equations: Za = ( (Z1*Z2)+(Z1*Z3)+(Z2*Z3) ) / Z2 Zb = ( (Z1*Z2)+(Z1*Z3)+(Z2*Z3) ) / Z1 Zc = ( (Z1*Z2)+(Z1*Z3)+(Z2*Z3) ) / Z3


Application of Y-delta transformations?

delta-wye is a common type of 3-phase transformer configuration. It offers a good voltage gain and the delta transformer is useful in unstable systems for removing the third harmonics. The transformation is necessary for analyzing the circuit.


What connection is the higher ampere between delta and wye?

For the same load, delta provides higher current than wye, or star.Wye voltage is 1 / 1.732, or 0.577 that of delta. (1.732 is the square root of 3.) This gives a power of 0.333 for wye, as opposed to delta. (0.5772 = 0.333)This is why (no pun intended) we use wye-delta starters on large motors - it allows them to come up to speed at 1/3 power, before switching to full power on delta.


How can you terminate a 3 wire wye motor to a 3 phase delta connection?

To terminate a 3 wire wye motor to a 3 phase delta connection you need a 3 phase transformer to convert from delta to wye. Do not lift the common neutral connections inside the motor and rewire for delta, because the voltages will be wrong.


What is an electrical three line diagram?

wye delta diagram


Is a step up transformer a Ynd or a Dyn?

Whether a transformer is 'step up' or 'step down' has nothing to do with the way its windings are connected, so it could be wye-delta or delta-wye.


What is wye-delta motor control?

It is a type of starter that allows a motor to be started across the line by starting the motor with a reduced inrush current. The motor is started in a wye configuration until it gets up to speed and then a timer drops the wye contactor out a draws the delta configured contactor in. The motor then operates in a delta wired configuration.


Should a star-delta motor be supplied wye or delta power?

A star-delta motor should be supplied star-delta.Wye is simply another name for star. Star-delta motors use a star or wye configuration to start, and a delta configuration to run. This reduces the voltage on the windings during the high current starting time.


What is the difference between an open delta and an open wye connection?

An open delta connection is a delta connection with one phase removed, but still supplied with three line conductors. An open wye is a wye connection with one phase removed, supplying a three line conductors and a neutral conductor. An open-delta/open-wye is a method of providing a reduced-load three-phase supply using just two single-phase transformers, rather than the preferred method of using three single-phase transformers.


How do you change 3 1phase transformer in to 3 phase?

Three-phase transformation can be obtained using two Transformers, by connecting them in what is known as an 'open delta' connection.


How much voltage does star-Delta starter give to motor at start?

A delta starter supplies what ever the supplied voltage to the line side of the contactor is. The inrush current is usually 300% of the full load amperage of the motor. Edit to above answer: Actually the question is for a Wye-Delta Starter (Wye=Star). There are two contactors, one in Wye configuration and one with Delta. The Wye is used to start and the Delta for run. This is a reduced voltage start scheme. Though the line supply voltage remains the same, for instance 480VAC, the phase voltage at the motor will be different for the Wye: V(phase) = V(line)/1.732 In a Delta V(phase) = V(line) So the Phase Voltage during the start will be 277VAC and then when the motor is spinning, usually after a set time delay, the Wye contactor drops out and the Delta contactor kicks in so that Phase Voltage is now the full 480VAC.


What kind of 3 phase dry type tranform is used when you are using 110V loads to balance the three phases of that transform?

It would normally be a "Delta" "Wye" transformer. Delta on the high-voltage side, and Wye on the low-voltage side. The Wye windings will give you the neutral needed for 110 v. circuits