What is power cable size for 1 kw 1 phase motor over 500 meters?

It depends on the voltage that the motor needs, because a higher voltage requires less current for a given amount of power. Also a higher voltage can tolerate a higher voltage drop. So there are two things that lead to a thinner wire when the voltage is higher.


What is the cable size for 11 kw 3 phase motor?

Incomplete data: To have an accurate result - please provide the following; 1. Voltage Rating - Low Votage or Medium Voltage Applications? 2. Efficiency 3. Power Factor 4. Distance - One way distance from source 5. Location and method and arrangement of Installation 6. Allowable or acceptable voltage drop 7. Type of cable - PVC or XLPE cable with same size has different ampacity


What would the cable size be for a 90 meter armoured cable with a 110 amp supply with a 330 amp start up?

To calculate voltage drop to size the wire, a voltage must be stated.


What is the cable size of 1600kVA transformer?

Cable size is determined by current. You did not provide the current, nor did you include the voltage so that we could calculate the current. Please restate the question, and include either the current or the voltage.


What is cable size for 48V DC 30 A?

The correct size of cable depends on the length of the cable run, as well as the voltage and current. Another consideration is what voltage loss is acceptable ? Safest answer would be to use a cable sizing table or online tool: http://www.solar-wind.co.uk/cable-sizing-DC-cables.html Hope that helps. G.

Related Questions

For 225 kw motor what is the amps star and delte and what is the cable size required?

Need to know what the voltage of the motor is.


What is the cable size for a 168 kilowatt 3 phase motor?

First of all find out what voltage the motor is designed to work on.


Which size cable use for 37 kw induction motor?

For a 37 kW induction motor, a cable size of approximately 10 AWG (American Wire Gauge) would be suitable for typical installations. However, the specific cable size required would depend on factors such as the length of the cable run, ambient temperature, and voltage drop considerations. It is recommended to consult with a qualified electrician to determine the appropriate cable size for your specific application.


What is the cable size for a 3KW motor 350 meter run for cable 240v?

For a 3KW motor with a 350-meter run and 240V supply voltage, you would typically need a cable size of around 16mm² for proper voltage drop considerations and to prevent overheating. It's recommended to consult with a qualified electrician or use a voltage drop calculator to determine the exact cable size needed for your specific installation.


What is the cable size of 110 KW motor?

The cable size depends on a few factors, such as the supply voltage, the method of starting the motor, (direct-on-line, or star delta) and the length of cable required to compensate for voltage drop. Also, if the cable is copper or aluminum.110 kW motor has a rated current of 200 amps at 415 volts, so the correct copper cable size would have a cross-sectional area of 75 square mm., if the motor is started direct-on-line.At 660 volts, the rated current would be 118 volts and the cable size would be 35 square mm.


What is the cable size for 1.5KW 3 phase induction motor?

Sir, what is the cable size for 1.5kw 3phase induction motor 400v?


What is power cable size for 1 kw 1 phase motor over 500 meters?

It depends on the voltage that the motor needs, because a higher voltage requires less current for a given amount of power. Also a higher voltage can tolerate a higher voltage drop. So there are two things that lead to a thinner wire when the voltage is higher.


What is electrical cable size for 18.5kw?

To answer this question the voltage is needed.


What size of wire use for 3kw motor 380volts 3phase?

How to calculate a cable size of 3kw motor


What is the cable size for 11 kw 3 phase motor?

Incomplete data: To have an accurate result - please provide the following; 1. Voltage Rating - Low Votage or Medium Voltage Applications? 2. Efficiency 3. Power Factor 4. Distance - One way distance from source 5. Location and method and arrangement of Installation 6. Allowable or acceptable voltage drop 7. Type of cable - PVC or XLPE cable with same size has different ampacity


What would the cable size be for a 90 meter armoured cable with a 110 amp supply with a 330 amp start up?

To calculate voltage drop to size the wire, a voltage must be stated.


How do you calculate cable size for 50 hp?

just apply the formula :-p=v*i*cos(angle);now you have the power rating,load so in turn power factor so you can easily calculate the value of current.with the help of current you can chose the cable available in the market either the aluminum or copper wiresatendra.svnit@gmail.com