answersLogoWhite

0

No it will not run

User Avatar

Wiki User

13y ago

What else can I help you with?

Continue Learning about Engineering

What is the voltage for a single phase from a 415 volt 3 phase and neutral supply?

240V. 415 / 1.73 = 240


What is the amperege of single phase and 3 phase 1kW motor operating at 230 volts single phase and 415 Volts 3 phase?

To answer your question properly, you need to know the input power to these machines, whereas you are specifying their output powers. In other words, you really need to know their efficiencies in order to determine their input powers.Once you have figured out their input powers, then you need to divide the power by the supply voltage in the case of the single-phase motor, and the power divided by 1.732 times the supply voltage in the case of the three-phase motor.Incidentally, your motors' specs should either be 230/400 V or 240/415 V, NOT 230/415 V.


Can you single phase 220VAC in place of three phase 220VAC?

Yes, just use L1 and L2 ( just 2 of the 3 legs), or one of the legs to a neutral wire if equipped. Just make sure the voltage is the same as the 220 volts you wish to have with single phase service.


How many amps for 250 kva generator per phase at 415v?

If the generator is 3-phase 120/208 v. it produces 104.21amps per phase using the formula 30,000 / (1.73 x 208 x .80). If it is 277/480 v. It gives 45.18 amps. A singlephase generator will give 125 amps at 240 volts and 62.5 amps at 480v.


What is generator KVA size for 3 phase 415 volt 7.5 kw 10 hp 19.5 A motor?

The only relevant number is the kw. Then you just divide by the power factor to get the KVA. 0.8 is a pretty typical PF, so that would give you a KVA of about 9.4. But motors can take up to 5 times their rated current on start-up, so you need to make sure you have a generator that will handle that instantaneous current.

Related Questions

What is the voltage for a single phase from a 415 volt 3 phase and neutral supply?

240V. 415 / 1.73 = 240


What does 3 phase voltage measure in Australia?

415 volts


What is the 3 phase power in Dubai?

415/240 V, 50 Hz


On trace heating 415 Volts if you lose a phase on a 3 phase system what percent of heating have you losed?

1/3 rd lost


What is the amperege of single phase and 3 phase 1kW motor operating at 230 volts single phase and 415 Volts 3 phase?

To answer your question properly, you need to know the input power to these machines, whereas you are specifying their output powers. In other words, you really need to know their efficiencies in order to determine their input powers.Once you have figured out their input powers, then you need to divide the power by the supply voltage in the case of the single-phase motor, and the power divided by 1.732 times the supply voltage in the case of the three-phase motor.Incidentally, your motors' specs should either be 230/400 V or 240/415 V, NOT 230/415 V.


What size generator do you need for a 700 amp farm everyday use?

Answer for UK, Europe and countries running a 50 Hz supply service.A farm that takes a 700-amp supply on 3-phase 415 volts is a big farm drawing 500 kVA so it really needs a 750 kVA generator that would be expected to use 60-70 gallons of diesel per hour. It should be noted that 3 phase 415 volts is a 50 Hertz generated supply.At lower voltages the power drawn would be less, but the answer is independent of the supply frequency.Answer for countries running a 60 Hz supply service.A farm that takes a 700-amp supply on 3-phase 208 volts is a farm drawing 250 kVA that needs a 300-350 kVA generator. It would be expected to use 30-40 gallons of diesel per hour.


Can you single phase 220VAC in place of three phase 220VAC?

Yes, just use L1 and L2 ( just 2 of the 3 legs), or one of the legs to a neutral wire if equipped. Just make sure the voltage is the same as the 220 volts you wish to have with single phase service.


Is the voltage in a three-phase system stated by the phase-to-phase or phase-to-ground voltage e.g. 500kV or 290kV?

The voltage in a three phase delta system is stated by the phase to phase voltage. If it is a wye connection the phase to neutral is represented by the two voltages. e.g. 120/208, 240/415, 277/480, 347/600, 7225/12500, etc.


What current is drawn by a 10KVA 415V 3 Phase Load?

10000 = 415 * i i = 10000/415 = 24 a <<>> The formula you are looking for when KVA is known is I = KVA x 1000/1.73 x E = 10000/1.73 x 415 = 10000/240 = 41.6 amps.


How many amps for 250 kva generator per phase at 415v?

If the generator is 3-phase 120/208 v. it produces 104.21amps per phase using the formula 30,000 / (1.73 x 208 x .80). If it is 277/480 v. It gives 45.18 amps. A singlephase generator will give 125 amps at 240 volts and 62.5 amps at 480v.


How many amps needed for a 45kw shredder 415 volt3 phase?

To calculate the required amperage for a 45 kW shredder operating at 415 volts in a three-phase system, you can use the formula: Amps = Power (Watts) / (Voltage × √3). For a 45 kW (or 45,000 watts) shredder, this would be: Amps = 45,000 / (415 × √3), which equals approximately 62.5 amps. Therefore, you would need around 62.5 amps for the shredder.


How many amps will a 3 phase 415 volt 12 kw heater draw?

100 KW divided by 415 volts is 241 amperes. Power = voltage times current, so current = power divided by voltage.