for thrust balancing.
it is used balance axial thrust on turbine rotor due to admitting of high pressure steam in to turbine. it basic purpose is to save thrust bearing.
Used in power generation. When steam turbine is on-line the Main Steam Stop Valve is fully open. When offline it is closed. Steam to turbine is controlled thru control valves after Main Steam Stop Valve
If,clamp is not proper fitted in control oil line that time it may happen cause in control oil line pressure also more than main oil pump disch.
The balancing line is a transmission line consisting of two conductors of the same type, that are grounded to the compressor's circuits and to the ground and helps keep external noise down.
Due to pascals law
To avoid slugging nozzles and blades inside the turbine with condensate on start-up; this can break these components from impact. The blades were designed to handle steam, not water.
The HRH line, or High-Rank Heat line, in a power plant refers to the pipeline that carries high-pressure, high-temperature steam from the steam generator or boiler to the turbine. This steam is used to drive the turbine for electricity generation. The HRH line is critical for efficient energy conversion and system performance, as it maintains the necessary conditions for optimal turbine operation. Proper insulation and maintenance of this line are essential to minimize heat loss and ensure safety.
it is used balance axial thrust on turbine rotor due to admitting of high pressure steam in to turbine. it basic purpose is to save thrust bearing.
The balancing line in a boiler refers to a specific operating point on a steam generation curve where the heat input from fuel combustion matches the heat output from steam generation. This line helps maintain efficiency and stability within the boiler system, ensuring that the steam pressure and temperature remain within desired limits. Properly managing the balancing line is crucial for optimizing performance and preventing issues such as overpressure or inefficient fuel use.
Used in power generation. When steam turbine is on-line the Main Steam Stop Valve is fully open. When offline it is closed. Steam to turbine is controlled thru control valves after Main Steam Stop Valve
If,clamp is not proper fitted in control oil line that time it may happen cause in control oil line pressure also more than main oil pump disch.
The objectives of line balancing are to optimize the flow of work, reduce idle time, and increase efficiency in a production line. Balancing the line helps to evenly distribute workload among workstations, minimize bottlenecks, and improve overall productivity.
Coal makes energy in 6 sorta simple steps. 1) The coal or natural gas is first burned for mainly thermal (or heat) energy. 2) That thermal energy is used to boil water and to produce steam. 3) That steam is then forced through a high pressure tube called a steam line. 4) The steam then pushes a turbine (which is very electrical and i don't know what goes on in there) 5) That turbine then produces electrical energy. 6) The electrical energy is transported to your home and then you use it for searching the internet on how coal makes energy! (how convenient!)
Not quite sure what you are referring to. In the reactor primary circuit, there are of course the main circulating feed pumps that transfer the reactor heat output to the steam raising units (PWR) or the turbine (BWR). In the event of a loss of the main power outlet line, the plant will safely shutdown, reactor and turbine/generator together, and these feed pumps will lose their electrical supply. But there is decay heat produced from the reactor and it must be kept cool to prevent fuel damage. Therefore emergency feed pumps are provided which can be run from back up diesel generators. In the PWR there is in addition the secondary loop which takes water from the turbine condenser and passes it through the steam raising units. Both types of reactor also have the turbine condenser cooling circuit which takes water from either a lake, river, or the ocean, or from air flow cooling towers, to condense the steam at the turbine back end.
The last two steps are:The steam or gas spins the turbinesthe turbines then turns the electric generators producing elecricity
Line replacement units
The balancing line is a transmission line consisting of two conductors of the same type, that are grounded to the compressor's circuits and to the ground and helps keep external noise down.