answersLogoWhite

0

Yes it can run because motors have 10% voltage variation tolerance so it can operate between 380v - 440v band.

User Avatar

Sonny Borer

Lvl 10
3y ago

What else can I help you with?

Continue Learning about Natural Sciences

What is the cable size for a 26kw induction motor 50metre run for cable 415v?

For a 26kW, 415V induction motor with a 50m cable run, you would typically need a cable size of at least 6mm^2 to ensure proper voltage drop and current carrying capacity. However, it is always recommended to consult local electrical codes and standards or a licensed electrician to determine the exact cable size needed for your specific installation.


Can you run a 570 volt motor on 480 volt three phase power supply?

No, it is not recommended to run a 570 volt motor on a 480 volt power supply. The motor is rated for a specific voltage to ensure optimal performance and prevent damage. Running the motor at a lower voltage could result in overheating and premature failure.


Can you operate a motor of 575 v 60 Hz with a power supply of 575v 50 Hz?

Operating a motor designed for 60 Hz on a 50 Hz power supply can lead to issues such as overheating and reduced efficiency. It's recommended to use a motor that matches the frequency of the power supply for optimal performance and to prevent damage to the motor. In this case, it's best to avoid operating a 575 V 60 Hz motor on a 575 V 50 Hz power supply.


How can you run a 380VAC 3-phase 50hz motor on a 220VAC 3-phase 60hz supply?

To run a 380VAC 3-phase 50Hz motor on a 220VAC 3-phase 60Hz supply, you would need to use a voltage converter to step up the voltage from 220VAC to 380VAC. Additionally, you may need to adjust the motor's parameters to account for the difference in frequency between 50Hz and 60Hz, such as adjusting the motor's speed rating and ensuring the motor does not overheat due to the increased frequency. It's important to consult an electrician or motor specialist to ensure safe and proper operation.


What is the simplest way to run a 3 phase 380 V motor of about 1 KW directly on 220 V single phase supply without resorting to rewinding or frequency converters?

You cannot run a three phase motor on single phase power. You'll burn the motor up within minutes. By the way, I've never seen or heard of a 380 volt motor. Do you mean a 480 volt motor? If so, the only way you can power it is with the correct full voltage and a 3 phase power supply.

Related Questions

Can a 415v 50hz motor run on 380v 50hz?

no


Can a 415V 3-phase 50 Hz motor run on 380V 3 phase 60 Hz?

Yes, it will run drawing little more extra current in similar conditions. The motor is expected to be running in lesser rpm as well.


How can you run a 220v 3-phase 60hz motor on a 380v 3-phase supply?

Not advisable, the voltage differential is too great.


Can a 440 - 480V 60Hz motor run in a site with 380V 60Hz supply If No how can it work?

The motor will run, probably at nearly the same speed, but it cannot supply the same mechanical load. If it can be run on a lighter load, proportional to the voltage, it should be OK.


If a 6.6KV Motor run at 415V then what happen to its current and RPM?

Current shall increase while you apply 415V for operating it and will decrease the rpm to a much low level.


Can a 415V motor run on 525V?

It is not advisable to do so. You may burn the winding, insulation may fail.


How do you make a 380v motor run on 220v?

Yes just connect any line to neutral you have 230volts already.


380v motor on 415v?

Answer for European SystemsThe nominal line-to-line voltage used for single-phase supplies in Europe is 400 V. In the UK, this voltage is allowed to vary between -6% and +10%; in other words, it can vary between 376 V and 440 V. So it would be quite acceptable for a 380-V and a 415-V motor to operate on this system.


Can you run a 415v 3 phase motor on 480 3phase?

It would not be immediately dangerous but there is a possibility of overheating with the 9% overvoltage so it isn't a good idea unless the motor is lightly loaded and watched very carefully. The safe voltage range should be marked on the motor.


Can you run a 460v 60hz motor to a 480v supply?

The the supply stays within +/- 5% of what the motor is rated for, you can do this.


How do you do solo test for motor?

just connect the supply of motor to power supply..and run..then ovserve the motor sounds,temperature and vibration.


How do run 380V motor in 440V supply voltage?

You can use a voltage regulator IC/transistor that can take any input voltage (to a point) and spit out whatever voltage you want, depending on your application (in this case 380 volts) then be sure you build a regulator with the correct IC/transistor. Hope this helps!