A 10 hp pump operating at 480 volts would draw approximately 15.6 amps of current. This can be calculated by dividing the power in watts by the voltage.

User Avatar

AnswerBot

1y ago

What else can I help you with?

Continue Learning about Natural Sciences

Can you run a 570 volt motor on 480 volt three phase power supply?

No, it is not recommended to run a 570 volt motor on a 480 volt power supply. The motor is rated for a specific voltage to ensure optimal performance and prevent damage. Running the motor at a lower voltage could result in overheating and premature failure.


How many amps will a 480 volt 3 phase 35 kw heating element draw?

To calculate the current draw of a 480-volt, 3-phase, 35 kW heating element, you can use the formula: [ I = \frac{P}{\sqrt{3} \times V} ] where ( I ) is the current in amps, ( P ) is the power in watts, and ( V ) is the voltage. Substituting the values: [ I = \frac{35000}{\sqrt{3} \times 480} \approx 42.1 , \text{amps} ] Therefore, the heating element will draw approximately 42.1 amps.


Can a 575 volt drive power a 480 volt motor?

It is not recommended to power a 480 volt motor with a 575 volt drive as the drive output voltage may exceed the motor's insulation rating, potentially causing damage to the motor. It is best to use a drive that matches the motor's voltage rating to ensure safe and efficient operation.


What color should a H2 Conductor on 480 volt transformer should be marked?

The conductor for H2 connection on a 480 volt wire transformer should be marked:


How do you wire a 277 volt heater from 480 volt box?

Answer for USA, Canada and countries running a 60 Hertz supply service.The 277 volt heater can be wired to a single pole breaker in a 3 phase 4 wire 480 volt distribution panel. The breaker should be sized to the amperage draw of the heater. 277 volts is the star point (wye) voltage of a 480 3 phase system. 480 / 1.73 = 277 volts. The third answer is not correct, two phase legs of a 480 volt system will give you 480 volts. It is the phase leg to ground (neutral) that gives you the 277 volts.A 277 Volt heater or device may not be wired to a 480 Volt circuit or box. A 277 Volt device may only be wired to a circuit rated for 277V/480V equipment.2 legs of 480 volts will give you 277. But since you don't know the answer you probably shouldn't be doing it! Please don't kill yourself, hire a licensed electrician.Before you do any work yourself,on electrical circuits, equipment or appliances,always use a test meter to ensure the circuit is, in fact, de-energizedIF YOU ARE NOT REALLY SURE YOU CAN DO THIS JOBSAFELY AND COMPETENTLYREFER THIS WORK TO QUALIFIED PROFESSIONALS.

Related Questions

How many watts does a 1000 watt 480 volt sports light draw?

Your question answers itself... 1000 watts, when operated on a 480-volt source..


Can you run 480 volt motors in a 380 volt system?

Can I run 480 volt , 60 HZ motor at a 380 volt , 60 Hz system?


Can 480 volt electric be run in emt conduit?

Yes 480 volt electric wiring can be run in emt conduit.


A 480-volt circuit has an impedace of 60 ohms what is the current?

480 volts and 60ohm impedence current = volt/impedence current=480/60 current=8ampeares


Can you run a 570 volt motor on 480 volt three phase power supply?

No, it is not recommended to run a 570 volt motor on a 480 volt power supply. The motor is rated for a specific voltage to ensure optimal performance and prevent damage. Running the motor at a lower voltage could result in overheating and premature failure.


How many amps will a 480 volt 3 phase 35 kw heating element draw?

To calculate the current draw of a 480-volt, 3-phase, 35 kW heating element, you can use the formula: [ I = \frac{P}{\sqrt{3} \times V} ] where ( I ) is the current in amps, ( P ) is the power in watts, and ( V ) is the voltage. Substituting the values: [ I = \frac{35000}{\sqrt{3} \times 480} \approx 42.1 , \text{amps} ] Therefore, the heating element will draw approximately 42.1 amps.


Should 2 legs of 480 volt 3 phase each have 480 volts?

Across a 480 volt three phase system, 480 volts should appear across L1 and L2, L2 and L3 and L3 and L1.


Will a120 volt meter blow up if installed in a 480 volt installation?

Yes


Can a 575 volt drive power a 480 volt motor?

It is not recommended to power a 480 volt motor with a 575 volt drive as the drive output voltage may exceed the motor's insulation rating, potentially causing damage to the motor. It is best to use a drive that matches the motor's voltage rating to ensure safe and efficient operation.


What color should a H2 Conductor on 480 volt transformer should be marked?

The conductor for H2 connection on a 480 volt wire transformer should be marked:


What is the amps of a 5.5 kw 480 volt 3 phase?

Current in 200kw at 480 volts = 200,000/480 = 416.667 amps


Wiring diagram to convert a 3 phase 480 volt generator to 277 volt?

You should not need a wiring diagram. If the generator has a star point (wye) connection then the phase voltage to ground (star point) is 277 volts. 480/1.73 = 277.