How many watts will a 1 horsepower 240 volt motor drawing 9 amps use?

Amps are not directly convertible to horse power, which is a measure of power. Power is current times voltage. Therefore on a 240 v supply, 9.2 amps equals 2208 watts. One horse power is 746 watts.

Why cant you use electrical energy directly form a high voltage line?

This is done in order to minimize power losses in the power distribution network due to the resistance of the transmitting cables. It should be noted that for a given cable resistance, voltage drop, and thus power dissipated in the cable and not available to use, is directly related to the current flow through the conductor.

According to the Power Law: P = I2 ×R, that is power (in this case, power lost) is equal to current squared times resistance. To deliver power, it takes amps and volts. If you raise the volts, you can reduce the amps and still get the same power. If you reduce the amps, you lower the losses. Did you notice the squared term in the formula? That means if you reduce the current to one-tenth of the original value, your losses go down to one one-hundredth of what they were.

This is a huge issue for the utilities. Every kW lost is one they cannot collect money for, yet they still have to pay for fuel to generate it, they have to size the generator bigger to supply it, and they have to size the transmission system to carry it. There are other good reasons too (see below), but minimizing line loss is the $main$ one. A few transmission systems have been designed at 1.2 million volts. The utilities would have billion-volt systems if they could figure out how to do it.

2nd Answer

A major reason is that, to carry the same amount of power, if the transmission voltage is made higher, then, even though a thinner cable has a higher resistance for a given length, the cables can be made thinner and lighter in weight.

Use of a higher transmission voltage saves a tremendous amount of money in many ways. For example for the expensive material used for the cables (often a steel multi-strand core wound with an outer skin of copper, aluminum, or similar good conducting wires) and for the weight and costs of construction and erection of the towers that carry the cables across the countryside.

To carry 400 kV (= 400 kilovolts = 400 thousand Volts) the steel towers have to be taller and the porcelain insulators have to be longer than they would have to be for cables carrying lower voltages but the cost of making the towers taller and the insulators longer is far less than the cost of the extra weight of the much thicker cables that would be needed to carry the same power at a lower voltage. *** (See Note below for more explanation)

There are many other costs which have to be reckoned when deciding what voltage to use for long-distance power distribution. For example the high cost of the massive power transformers and big switching stations that have to be included in the power distribution network; the power that is lost from the cables - radiated to the surrounding air as heat - because of the electrical resistance of the materials from which the cables are made.

The above answer just gives a very simplified overview of the kinds of things a skilled power transmission engineer has to work with and calculate when designing a new power transmission network.

3rd Answer

Transmission and quantum of electricity can be considered analogous to hydraulics. Reckon voltage as pressure, the longer the distances, the higher the pressure required to pump. That is why for long distance transmission high pressure (voltage here) is required, failing which, the power will not reach the destined end. It will dissipate on the way. Reckon current as quantity which will be drawn from the pipeline (cables here) at the pressure/voltage required.

*** Note:

If we use the Electric Power Equation we can get an idea of what the descriptions given in the answers above really mean:

P = V × I or, in words:

P (power) = potential difference V (voltage) times current I (amperage)

So, using simple mathematics we can say that:

I = P / V or, in words:

Current I (amperage) = P (power) divided by potential difference V (voltage)

Now, as an example, if a small town needs to have a supply of power W of say 1 MW (= 1 megawatt = 1 million watts) to be delivered over cables from a power generation station:

Calculation A:

If the voltage V used for transmission through the cables is 1000 Volts then the current I in the cables would have to be:

P / V = 1,000,000 / 1,000 = 1,000 amps

which would require a very thick and heavy, and therefore very expensive, cable and associated support towers.

Calculation B:

If the voltage V used for transmission through the cables is 400 kV (= 400 kilovolts = 400,000 volts) then the current I in the cables would have to be:

P / V = 1,000,000 / 400,000 = 2.5 amps

which can be carried safely in a very much thinner, lighter and less expensive cable and support tower.

Line supports are mainly two types:

1. poles

Poles are classified as wood poles, concrete poles and steel/aluminum poles.

2. towers

Towers are classified as self supporting towers and stayed/guyed towers.

Self supporting towers are in two types: wide base and narrow base.

Stayed towers are classified as portal type and V-type.

What are common uses of a common emitter amplifier?

bcause amplification factor beta is usually ranges from 20-500 hence this configuration gives appericiable current gain as well as voltage gain at its output on the other hand in the Common Collector configuration has very high input resistance(~750 kilo ohm) & very low output resistance(~25 ohm) so the voltage gain is always less than one & its most important application is for impedance matching for drivingh from low impedance load to high impedance source

Why the generating station rating is in KW though the rating of generators in KVA?

The volt ampere is a measurement of apparent power, while the watt is a measurement of true power. Apparent power is simply the product of voltage and current; the output of a transformer, therefore, is the product of its rated secondary voltage and its rated secondary current -i.e. the apparent power of the transformer. The power supplied, in watts, is determined by the power factor of the load, so there is little point in rating a transformer in watts, as the designer has no means of knowing the power factor of the load it is to supply.

What is the power factor of an induction motor?

Induction motor comprised inductor as the most part in it and an inductor has the characteristic to oppose the change of current, i.e., it has lagging power factor as current lags behind the voltage. Hence, an induction motor works on lagging power factor.

How do you calculate a human's output of power?

well...depends on what the person is doing. The average person burns about 2000 calories a day. That can be calculated out into any number of things. If you want raw power output data about a specific task you would simply use a horsepower formula (550 ft·lbf/s) because:

1 hp ≡ 33,000 ft·lbf/min by definition

= 550 ft·lbf/s since 1 min = 60 s

= 550 × 0.3048 × 0.45359237 m·kgf/s since 1 ft = 0.3048 m and

= 76.0402249068 kgf·m/s

1 lb = 0.45359237 kg

= 76.0402249068 × 9.80665 kg·m²/s³

g = 9.80665 m/s²

= 745.69987158227022 W since 1 W ≡ 1 J/s = 1 N·m/s = 1 (kg·m/s²)·(m/s)

Since horsepower has nothing to do with a horse, and a horse is typically rated at about 18 horsepower, and a human is roughly 1/10th the size of a horse, your cheap answer is that a typical human is about 2 horsepower.

How many amps does a 240 volt 7.5 hp motor draw?

whats the voltage??? at480 volts the Fla would be 33.75 or 35 amps. at 230 volts it would be 70 amps. i would go with the 480 myself because its less amps.

<<>>

The voltage stated in the question is 600 volts. There are 746 watts in 1 HP so in 20 HP there would be 746 x 20 = 14920 watts. I = W/E. 14920/ 600 = 24.8 amps. The proper formula to use would be I = HP x 746/1.73 x E x %Eff x pf. Without knowing the efficiency and power factor of the motor an accurate answer can not be given. In the trade, a quick rule of thumb is, for 600 volt motor installations, it is 1 amp per horsepower which is close enough to calculate the feeder wire size.

Can electricity pass through plastic?

For the flow of Electric Current, the material must contain free electrons.

If there are no free electrons, then to conduct electricity the applied voltage must exceed breakdown voltage.

Plastics under ordinary state does not have free electrons but if high voltage is applied then it can start conducting.

Circuit breakers can be reset and used again?

Yes.

In most cases, yes. If the circuit breaker continues to trip when there is no fault in the circuit, it may be failing and need to be replaced.

What increases resistance in a wire?

Current (measured by an ammeter)

and

Voltage (measured by a voltmeter)

R= V/I

Resistance equals voltage divided by current

================================

That's wonderful, but the measurement doesn't "affect" the resistance

of the wire.

The factors that do "affect" the resistance ... i.e. determine what the

resistance will be ... are

-- substance of which the wire is composed

-- dimensions of the wire: thickness and length.

Would it be correct to say with a fixed field voltagethe speed of a shunt motor is proportional to its armature voltage?

With increasing torque load the armature tends to slow down; the motor draws more current to compensate, and if there is armature resistance the back emf generated by the armature falls to allow the increased current to flow, which causes the motor to settle at a lower speed.

The mechanical output power is the speed times the torque, and increasing the torque increases the power output provided the speed does not drop much.

Why dont you use earth wire place of neutral?

Earth is neutral, but only at the distribution panel and upstream from it. Downstream of the distribution panel, earth and neutral shall not interchange or cross connect their connections or their roles - earth is protective ground - and neutral the current carrying return conductor.

How do you convert a 4 input NOR gate into multiple 2 input NOR gate?

you will need 2 two input AND gates to do this. connect the output of the first to one input of the second. you now have a three input AND gate.

just remember when calculating timing that 2 inputs of the 3 have twice the gate delay of the remaining input, thus the output will have skew and possibly glitches. if timing is critical or glitching can't be tolerated it may be best to use an actual three input AND instead of kludging one.

What is the difference between ground and floating neutral in your electric panel?

Neutral is vital to complete the cicuit. Ground is vital to carry the current to earth during a malfuntion of the appliance using power to drive it, should the current come in contact with the frame or outer covering of the appliance and endangering the users life.

If you have 2 5-watt bulbs connected in series and then in parallel which circuit arrangement will give you brighter bulbs?

It depends on the voltage rating of each lamp, and the value of the supply voltage. It's important to understand that a lamp will only operate at its rated power (therefore at its full brightness) when subject to its rated voltage.

So, let's assume each lamp is rated at, say, 24 V.

If connected in parallel across a 24-V supply, then they will both operate of full brightness.

If connected in series across the same 24-V supply, then each lamp will be subject to half its rated voltage, and will be very dim.

On the other hand, if connected in series across a 48-V supply, then they will each be subject to 24 V, and will both operate at full brightness.

Why you use delta and wye connection in 3 phase system?

You are unqualified to do. This is not a simple wiring problem. 3 phase is industrial power and should be handled by someone licenced. There are dozens of reasons why. Hi I think we need more info on what you are trying to do. 3 phase to 3 phase up or down, or 3 phase to single phase

The reply that from If you have to ask ... is not in keeping with the spirit of WikiAnswers.

First off, this could be a request from an engineering or engineering technology student.

Second, 3-phase power is not industrial power --- every home has at least 2 3-phase connections (i.e., dryer and range outlets).

Third, many engineers who do work in the power/energy sectors are not licensed electricians. Depending on the employer (e.g., Federal govt, aerospace, defense), they may not even be a licensed PE, much less a licensed PE in EE or NE. Many do not even have an FE/EIT certificate.

The question though, is rather vague and should be written in a more descriptive manner.

The following links are useful in providing information:

http://ecmweb.com/mag/electric_basics_deltawye_transformers/

http://www.frost.com/prod/servlet/market-insight-top.pag?docid=10530632

http://www.federalpacific.com/university/transbasics/chapter3.html

What is a measure of an object's ability to transmit electricity?

Electrical resistance. Ohms.

How well something conducts electricity is called its conductance, which is measured in siemens (S). Conductance is the reciprocal of an objects electrical resistance.

G=1/R

How do you calculate 440v phase?

Let's get the terminology correct. A 'phase voltage' is measured across a phase, whereas a line voltage is measured between two lines. So there is no such thing as a 'phase to phase' voltage -it's a line to line voltage (hence the term 'line voltage').

Does the voltage moves?

Yes, voltage is a kind of electric pressure. It is also called potential. When there is potential difference between any two points, current starts flowing from high pressure point to low pressure point.

FOR EXAMPLE : When there is a difference in air pressure between two regions, air moves from region of low pressure to region of high pressure causing winds

In this case air is the potential and wind is electric current

What is the opposite force of current flow?

Regarding electricity, the opposite force to a current flow is called "resistance" for Direct Current [DC] circuits, and "inductance" for Alternating Current [AC]. Regarding fluids [like air, water, or oil for example] that opposite force is refered to as "drag."

How do you make an electric motor stronger?

I suppose you could somehow increase the amperage from the battery to make the motor spin faster but it would probably burn out. Of, if there is some sort of gear drive you could put a larger gear on the motor and smaller one on the wheel but then you would lose power and may have to push it to get it going.

In order to make your scooter go faster, you would have to change the speed control unit and batteries. No matter how many batteries you add to your scooter you will burn out the speed controller. Your best bet to go faster is to buy a bigger watt scooter from the git go or get a gas one.

Use a voltmeter to find out how many volts are lost between the battery and the motor at full load. If more than one volt, install a foot switch and some heavy cable to bypass the controller and wiring.

you must choose a Honda products,it has more speed and less weight.and Honda products has many service centers

Take it to a professional. I bought an Ajutor electric bike that went a laughable 20km an hour then i took it to one of my friends work where a guy who knew a little about them disconnected the retrictor from under the foot pannel and know it goes a respectable road worthy pace!. Me and my grandad try to do it ourselves and we nearly broke it!. I paid £20 and now it goes like a restricted petrol scooter which is better than a restricted electric scooter. Don't mess about with the restictor yourself it can really wreck your battery.

you must buy a new one or...you must lessen the motor's/scooter's weight

OR, get a +5 from mykwilwin.com this wire adapter allows you to easily ad a (7.2volt) or (8.4volt) r/c or airsoft battery to your electric scooter or pocket bike for added speed without spending a fortune