What is the advantage of integral starter motorised valves?
Integral stsrters are embedded with motorised valves. By using integral starter, one can control motorised valves by remotely and locally. Even it can indicate the motorised valves direction of rotation & its final position, Power failure detection , indicate motor winding temperature, auto phase correction and emergency shut down of valve.
Advantages and disadvatages of a self excited induction generator?
The main disadvantage should be obvious - when the output voltage of the generator is used to provide field current to the generator....what happens if the output voltage sags? If the output voltage becomes depressed, the output power of the generator is compromised (becomes less and less), this in turn can cause the output to become more depressed, leading to an incrementally decreasing output capability.
The main advantage is cost savings.
What precautions should be taken when connecting an electrolytic capacitor in circuit?
Most electrolytic caps are polarized, so they will only go in a DC circuit one way - if you reverse them, they will explode (wear goggles!).
Why generally the high voltage side of transformer is delta connected?
I don't know what kind of transformer you are talking about, but most utility distribution transformers are star connected on the primary side.
AnswerIt might be different in some other countries, but in the UK, three-phase distribution transformers are always connected in delta on their primary (high voltage) side, and in star (wye) on the secondary (low voltage) side. The primary line voltage is 11 kV, while the secondary line/phase voltages are 400 V and 230 V.
In the United States and Canada, the primary winding is also connected in delta -however, the secondary side is also connected in delta, with one phase centre- tapped to provide the split-phase 240/120 V arrangement.
The reason for using a delta connection is because three-phase high-voltage lines are supplied as three line conductors -there is no provision for a neutral- so there is no practical advantage in having a star-connected primary.
Why it is dangerous to supply power to an unloaded series connected DC motor?
Starting torque becomes very high due to which motor can attain very high speed and can damage its body and connected equipments.
eddy current loss in the transformer core is reduced by
For DC circuits, an alebraic sum is required.
For AC circuits, a phasor sum is required.
Different b/w a moving coil instrument and a moving iron instrument
If you were to mechanically rotate the armature in an electric motor what would happen?
You said "armature" so it is a dc motor. Hence if the field is permanent magnet type then a voltage appears at the armature terminals nd its magnitude depends on the speed nd magnetic field strength. If it's field coils, then they must be seperately excited (if it don't possess residual). By changing the field strength you can vary the voltage produced at armature terminals.
Highly inductive load as a constant current source?
An inductor is a device that resists a change in current. The equation is di/dt = v/L. This means that inductors are current sources, and given a sufficiently large inductor, in comparision to the circuit, it is a constant current source.
What is the peak value of current if its rms value is 2A?
If an AC current is sinusoidal, then the peak value of a current with an RMS value of 2A is 2.8A, or 2A times the square root of 2.
However, very few current waveforms are sinusoidal. In fact, they are often far from sinusoidal - they are more often pulsating - because most power supplies, even switching power supplies, only draw current when the rectifier diodes conduct to recharge the primary filter capacitor. That only occurs once (half wave rectifier) or twice (full wave rectifier) each line cycle.
The square root of 2 rule does apply if the load is purely resistive and the voltage is also sinusoidal. Most voltages are also not sinudoidal, because of the pulsating current issue, and because conductors are not perfect zero impedance conductors. Voltage waveforms, however, are more closely sinudoidal than current waveforms.
The most accurate way to measure the peak current value is to observe it with an oscilloscope. If you want the analytic approach, you need to back calculate from peak value to RMS value, knowing that RMS value is the square root of the sum of the squares of the observations divided by N, as delta T approaches zero, and N approaches infinity. (Best to just use the oscilloscope.)
How does doubling the frequency effect the reactance of an inducter and capacitor?
for inductor, reactance XL = 2*pi* f *L, if frequency doubles then reactance increase. But for capacitor, reactance Xc = 1/(2*pi*f*C). In this case if frequency doubles the reactance decrease.
Why high voltage line workers keep left hand in pocket?
If you touch a power line with one hand, the current goes through your body. If you touch it with two hands, the current goes through your heart. They keep one hand in their pocket to prevent touching the line with both hands.
Input resistance and output resistance of Voltage series feedback amplifier?
output resistance decreases and input resistance increases
Do modern homes use electricity that is arranged in series or in parallel circuits?
In a modern home you use parallel circuit's. The reason why they are parallel circuit and not series is For example: say your kitchen light goes off, if that light goes off the others in your house won't. They also use parallel circuit in schools.
However, when there is a switch in the circuit, that switch is in series with the load, so you could say that electrical wiring is arranged in series-parallel.
What is the resistance of that draws a current of 25 amperes from a 1.5volts dry cell?
1. Theoretical Answer
R=1.5/25=0.6 Ohms
2. Practical Answer: Dry cells will not be able to deliver 25A as there are two limtation
a) Internal Resistance that limits the max current.round couple of Ohms. Max current that it can supply is about 1-2 A.
b) Capacity of Dry cells which are typical 700maHr. Even if cell could supply 25A it will only be for 1.7 minutes and then cell will become dead.
c) as the cells get drained there is increase in internal resistance which will further reduce the current.
What is the exact resistance value for ground or earth?
There isn't one. Soil type, water content, etc. cause this to vary.
Elastance is the reciprocal of capacitance so what is the reciprocal of inductance?
electric reluctance
What is difference between cold load and hot load?
hot load occurs when the power is high and the cold load occurs when yhe power is low
What is relation between power factor and phase sequence?
The power factor of an AC electric power system is defined as the ratio of the real power flowing to the load to the apparent power,[1][2] and is a number between 0 and 1 (frequently expressed as a percentage, e.g. 0.5 pf = 50% pf). Real power is the capacity of the circuit for performing work in a particular time. Apparent power is the product of the current and voltage of the circuit. Due to energy stored in the load and returned to the source, or due to a non-linear load that distorts the wave shape of the current drawn from the source, the apparent power can be greater than the real power.
In an electric power system, a load with low power factor draws more current than a load with a high power factor for the same amount of useful power transferred. The higher currents increase the energy lost in the distribution system, and require larger wires and other equipment. Because of the costs of larger equipment and wasted energy, electrical utilities will usually charge a higher cost to industrial or commercial customers where there is a low power factor.
Linear loads with low power factor (such as induction motors) can be corrected with a passive network of capacitors or inductors. Non-linear loads, such as rectifiers, distort the current drawn from the system. In such cases, active or passive power factor correction may be used to counteract the distortion and raise power factor. The devices for correction of power factor may be at a central substation, or spread out over a distribution system, or built into power-consuming equipment.