Best Answer

It will only work properly if you put it very close to the foot valve. In which case you may as well replace the foot valve - it's not difficult to do. If you put it at or near the pump, the pump will just suck air.

User Avatar

Wiki User

11y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: Can you put a check valve in line to a water pump if the foot valve is leaking?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

What could cause the water tank on a well system to squeak every 2 or 3 minutes?

foot valve leaking,


What is the function of foot valve in the pump?

A foot valve, in relation to a water well, is a check valve at he bottom of a well to keep the water from running back into the well from the pump when the pump is not running. If the check valve does not hold the water the pump will lose it's prime and will not pump water.


Car runs and then it dies and have to keep foot on gas to keep it running?

PCV valve may need replaced or the air intake may be leaking. Check for holes in the intake system or vacuum leaks.


How do you know if a well water check valve is bad?

You pop the seal and see if it closes properly. If there is any doubt at all, it's easy to change. - If you are operating a jet pump and it won't prime, the foot valve ( just a different check valve ) is always suspect.


Will faulty foot valve restrict supply of water?

faulty foot valve will lead to absence of water column in a line. this gives rise to cavitation in pumps. As a result, suction of pumps is affected.


What is a foot valve?

A foot valve is something that you eat with your foot


How do you determine if the foot valve is bad in a deep well pump or if there is a problem with the bladder tank?

When the check valve failed to seat properly at the lower unit in our well, the reserve tank would drain down quickly and then the pump would run again and again and again, . . . If you have a valve between the pump outlet and the tank you can turn it off to check operation of the tank. Most likely your valve has failed. It did this very often until we had the entire mechanism in the well replaced and installed a submersible pump. No problems since and the submersible pump is hardly audible compared to the old pump motor which was mouted near the well head in the basement. Good luck. Bob Jarnutowski bobjarn (at) hotmail.com Ans 2 - A deep well pump does not have a'foot valve' -they are only on a jet pump. You have NOT told us the exact problem. If the bladder tank is not holding water then you may have a faulty check valve on top of your deep pump. Splits in the pumpdrop line down the well are also common. -The bladder in the tank can also be faulty. -You must tell us ALL symptoms , not just ask about two things you've heard names of. Best solution - call a well tech , NOT a plumber !


How do you pull pipe to check foot valve?

You disconnect the horizontal pipe from the vertical well pipe at the wellhead, and pull up the vertical pipe.


What is a foot trap?

Are you sure you don't mean 'foot valve' - this is the valve at the bottom of a well suction pipe when you use a jetpump. I've never heard of 'foot trap'.


We have an old well lined with stone that isn't keeping up with our demand for water. Can I haul water to put in the well?

You will have to dig the well deeper and adjust the length of the pipes to reach the water where the foot valve or pump is.


Why does my 1992 oldmobile bravada keep shutting off on me when i have my foot on the break?

Possible vacuum leak either under hood or under dash Check valve on brake booster?


Symptoms of Valve seals leaking?

If the valve stem seals are bad the intake valves will "suck" oil into the cylinders. One common indicator of worn valve stem seals is to take your foot off the accelerator for several seconds when going downhill, then watch for smoke when you step on the accelerator again. If you see a puff of BLUISH smoke, you probably have bad valve stem seals. The catalytic converter can become oil fouled so that would be another indicator that you might have valve stem seal problems.