answersLogoWhite

0


Best Answer

Probably. More importantly, why would you want to? The Star/Delta starting method is used to minimize motor starting current, just like a soft starter. Use one or the other. There's no good reason to use both, it will just make things more complicated.

User Avatar

Wiki User

12y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: Can you use star delta starter and soft starter in to same motor?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

What device may be wired into the starting circuit of a motor to improve the starting torque?

I assume a 3 phase, AC induction motor. A star delta starter or a soft starter can be used. A soft starter is better compared to a star delta starter, but it is more expensive.


Soft starter for a dc motor?

It is an advanced power electronic device to start the motor with a very smooth starting curve. It is next generation starter compared to DOL or star Delta starter


What are the different types of starter?

DOL, Star Delta, Soft starter, VFD


Is DOL starter is sufficient for 10HP 2880 RPM motor?

If the application is high starting torque, then go for star delta or soft starters. If not DOL will do.


Why we used starter in motor?

There has to be device or a mechanism to start and stop a motor. hence a starter is needed. There are many different ways to start a motor. Considering AC Motor - It could be DOL, Star-Delta starters, which are age old and conventional. Star Delta starter starter is for higher rating motors, example over 7.5 kw, depending upon type of load. There are more advanced starters like Soft starters and Drives also.


Why starter used in motor?

There has to be device or a mechanism to start and stop a motor. hence a starter is needed. There are many different ways to start a motor. Considering AC Motor - It could be DOL, Star-Delta starters, which are age old and conventional. Star Delta starter starter is for higher rating motors, example over 7.5 kw, depending upon type of load. There are more advanced starters like Soft starters and Drives also.


What is the advantage of a Star Delta Motor Starter?

The inrush current to the starting motor is lower due to the the motor coils being in series across the line creating a higher impeadence. When the starter connects to delta connection the motor is already turning and it does not have to go through the locked rotor phase. This system is being phased out now with the use of electronic soft starts and by-pass contactors.To start a motor direct on line (DOL) in delta requires approximately 6 to 8 times the full load current of the motor and delivers full torque. Delta places 415v across each of the windings on the motor. A Star-Delta starter starts the motor in Star which places 240v across each winding on the motor. This results in a lower starting current and also a lower starting torque.


What are different types of starters?

DOL, Star Delta, Soft starter, VFD


What is the difference between a star-delta starter and a DOL starter?

At least two types of 3-phase electric motor starter are available: Direct-On-Line (DOL) and Star-Delta.For more information about how they work, and the differences between them, see the answers to the Related Questions shown below.


In 3 pH Delta motor connection the upstream ACB is tripping due to ground fault protection while motor starts with soft starter why?

Check the earth fault trip off set limit of the ACB. It may be too low.


Soft starter tripping?

Most of the motors are usually controlled by the soft starters which usually trip frequently. One of the steps in find why the soft starter has tripped is looking at the motor circuit protector rating.


What is a soft starter?

A soft start is a starter that bring a motor from the starting point of a slow speed in to a multiple speed that can be programmed in the starter Imagine you have a big plant in your factory, the voltage will go down/up when the plant start/stop, cause the sharp start/stop The soft starter is controlling AC motor in soft start/stop to eliminate such problems. Reference: http://www.softstarter.org