Q: What causes the air conditioner on a 2003 Chevy trailblazer to stop blowing through the ac vents and start blowing through floor and defrost vents?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

Your central air conditioner turns on but is not blowing through the vents?

If central air conditioner turns on but is not blowing through the vents, check the filter. If it is dirty, change it. Change the thermostat into cool, this will defrost the air conditioner.


What causes the front air conditioner on 1999 Lincoln navigator to stop blowing through the ac vents and start blowing through the defrost vents?

When there is a problem in the vent system it defaults to defrost setting. Check the doors & vac supply


How come ford heat and ac changes from blowing through the panel to blowing through the defrost how do i trouble the vac system?

you have a vac. leake or the oneway check valve is not working.....


When the battery was disconnected the air stopped blowing through the front vents on your 2004 trailblazer why?

No power, no air! Simple


Why is air conditioner running outside unit but not blowing inside?

If your air conditioner is running outside by not blowing cold air inside through your vent, your indoor coil is frozen. You will need to turn everything off and allow the unit to thaw out.


Why does 2000 Buick Lesabre Custom Air Conditioner blow only through defrost vents?

The vacuum supply line from the engine is disconnected or broken. When the vacuum supply is cut off the system defaults to the defrost mode.


AC vents blowing through Defrost and bottom vents 05 crown vic?

2003 crown vic air conditioning vent dont blow


Where is the air conditioning line on a 2003 Chevy Trailblazer?

The 2003 Chevrolet trailblazer air conditioning line can be found on the air conditioning compressor. The line goes from the compressor to the firewall. The line will go through the firewall to the air conditioner core.


In your 1997 mustang the air is blowing through the defrost Why isn't it blowing through vents?

this one is easy your switch the controls the vents is not working there is a flap the closes the defrost vents so that it goes through the other vents or there is a vacumn line that is controlled by the switch, and its leaking. The vacumn line is usually on the engine side of the firewall. It is a very small plastic tube comming out of the middle of the firewall at the top and it connects to a junction with other vacumn lines. See if any of them are disconnected.


What would cause ac to stop blowing through the vents and start blowing through defrost and air not being very cold on a 1995 ford ranger?

Check your blend door for proper operatin. Check your ac gas level. make sure your condenser and orice tubes are not stopped up.


Air not blowing through vents just floor and defrost on a 2002 jeep?

when it happened to mine, it was because the arm behind the dash that controls the internal vent doors slipped off


2002 winsrtar lx ac started blowing only through defrost vents onlytried turn every know still only blows through defrost vent?

Check under the hood for a disconnected or damaged vacuum line. The controls are vacuum operated and if the vacuum supply is cut off the system defaults to defroster only.