Hi: Your possiblyexperiencing a very high air velocity through your coils that they were not designed for. I have seen this before ( but ) rarely in a factory designed system designed and installed as a whole system at one time. In al likely hood, you have a mix matched blower to cooling coil set up. The blower is probably squirl cage design ( which is fine ) but for some reason it is running way to fast or the just plain way to large. Questions to ask yourself: #1, Has fan speed been changed? #2, Has fan squirl cage blower been chaned? #3, When did this situation start or has it always been so? #4 Have you had a much larger blower unit installed without changing the rest of your system? #5, Is your cooling coil running much colder than designed for? This would cause more humidity to fall out of the air much faster than it was designed for. It is my opinion that your system has most likely been field modified in some manner which has caused this. Really Really Really sounds like a induced problem nature than one that would naturally occure in a factory designed system. You do know that fan motors come in many speeds ? ( Right ?), The variations in speed design from one motor to the next can be extreme to say the least (even though they look the same and use same voltage) Also the pitch of your blower blade and the depth and number can make huge differences. There is more: I will not go there unless you need and ask. Hope this helps: Jimiwane

User Avatar

Wiki User

16y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: What would cause water to blow off of A coil Have a lot of water blowing off coil and onto side of plenum and then leaking down into furnace. The drain is clear...this water is being blown off Coil.?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

Would a bad plenum cause a car to overheat?

No It would not unless beside that plenum on your block is a crack in your heads and your leaking coolant or even leaking internally check head gaskets


What is the approximate external static pressure in the supply air plenum of a forced warm air furnace?

Approximate external static pressure in the supply air plenum of a forced warm air furnace is 0.2" w.c to 0.5 "w.c


Can you replace a furnace without replacing cooling system?

yes....just need to support evap coil and plenum while removing furnace and seal back up once furnace is set into place.


Where is the bonnet on a central heat gas furnace?

It sets on top of the fire box and the plenum set on top of that


Where is the hvac plenum?

A plenum is the ducting both prior to and after the furnace or /AC coil if the system has AC as well. It is often sheet metal, however today they may be made from duct board a light weight, insulated product.


What causes oil in the intake manifold?

Need more info.- make / model / engine... Could be a leaking seal in a turbo, leaking / blown intake plenum gasket, fault crankcase vent valve, etc.


What is an up flow furnace?

An up-flow furnace is a heating device that draws in air from near floor level in a building, heats it and then discharges the warmed air through a vent or plenum at the top of the machine. The warmed air is then fed into ductwork that distributes it throughout the building. This type of furnace is useful for installation below the area to be heated.


Why is my 1995 grand am floor wet?

Your heater core may be leaking, the condensate drain of the AC might be blocked, you can have a leak in one of the windows, or in the intake plenum to the ventilation .


What is causing antifreeze to leak into oil on Chevy Lumina?

Upper intake manifold plenum leak/crack most likely. If its blowing out coolant then you probably have a bad head gasket.


How do you Change intake manifold gaskets on 1994 Chevy cavalier Z24?

The best thing to do is buy a Chilton's or Haynes manual. There are two gaskets associated with the intake manifold. The upper plenum and the lower plenum. A lot of times it's just the upper that is leaking. It's fairly simple to unbolt and change. The lower involves removing the upper plenum, injection system, and other components. Buy the book.


Why does my 2004 Oldsmobile Alero accelerate on its own?

I would thinh you have a leaking plenum gasket thus allowing extra oxygen into the fuel air mixture leanig it out and making rpm's go up.


Why is black material coming out of house air conditioning vents?

If you have an oil or gas fired furnace, you may have a cracked plenum, in which case you may be getting exhaust inside the house. Call a specialist right away.