Best Answer

A motor that works intermittently would make me suspect a loose wire or a speed control switch that was corroded or going bad.

User Avatar

Wiki User

17y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: Why would a blower fan only work once in a while on a 94 Dakota resister bar has been replaced?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

Why would the heater quit working while driving on 03 trailblazer and then only come on if the heater output is on level 5?

You have a bad blower resister..............


Why does only the high speed setting on your 2001 Dodge Dakota work while the other 3 settings do nothing?

The blower motor resistor pack is defective. Replace it.


You replaced the blower motor for the heater of your 92 beretta it worked for a while then stopped Any ideas on what to do next Thanks?

Check the fuses and blower relay. Also check to make sure that the replacement blower motor has not failed. If these items are good then the electrical system will need to be tested to see where the blower system is losing power.


1999 Dodge Dakota heater core replacement?

I need mine replaced too. I'm tired of smelling anti-freeze while driving.


If its not the fuse how do you figure out why the heater fan stopped working on your 95 GMC Sierra 2500?

Check for 12V at the blower motor connection with ignition on and while selecting all blower speeds with fan switch. If you have power with all speeds at that connection you probably have a bad blower motor. If you don't have power there with any speed selected you probably have a faulty fan switch. If you have power there with only some of the speed selections you probably have a bad speed resister. If you power there at all speeds but high you probably have a bad high speed relay.


How do you fix the blower motor of the heating AC unit on a 98 Grand Cherokee The air only blows while accelerating?

Check the resistor pack on or near the fan , it may have melted and needs to be replaced.


Where is the front Blower Motor and blower motor resistor board located on a 2000 Mercury Villager?

Open the glove box door and remove the glove box. You should now be able to look directly at the motor and the resistor. >In 1999, they changed from the coil type resister to a printed circuit board. The coil type is about 2 1/5" long by 1 1/2" wide with kid of a square 4 wire connector. > The 2000 printed circuit type is about 4" long by 1/2" wide with a 4 wire connector with all the wires in one row. It's right up against the fire wall and partially hidden by the carpet. It's there, you just have to look. The tube you see is a cooler tube for the blower motor. It takes air out of the plenum case and directs it though the tube and into the motor housing. > > By the way, if the resister has the internal fuse burned, you probably have a blower motor starting to fail and it's drawing too much current at times. It will get worse. > You need a blower motor from a 99-02 Villager/Quest. >In doing some research on my own problem, which is the same as yours, I came across an answer for both of us. From March 2006 there was an answer that said that the control module was bad. He said that this used to be called a resistor pack. It's located behind the glove box. He said you open the glove box compartment and make it swing all the way down by squeezing in on the sides. You'll see the module attached to plenum with two plugs connected. Unscrew the two screws to get the module out. New part number from dealer is 5179985AA. The original part number has been discontinued. He said (in 2006) that the dealer cost for the module was $56.00 and you can replace it yourself in about 10 minutes. Blower Motor Control - Manual Control System The position of the blower motor control knob determines the speed at which the blower motor (18527) operates. Each position of the blower motor control knob is detented for positive engagement. The blower motor control works in conjunction with the blower motor resistor to control the four-speed operation of the blower motor. The blower motor control switch can be replaced separately from the manual control assembly. Blower Motor Control - Electronic Control System The rotation of the blower motor control determines the speed of the blower motor. The blower motor control works in conjunction with the A/C blower motor speed control (19E624) to control the 12-speed operation of the blower motor. Blower Motor The blower motor (18527) is mounted within the A/C evaporator/blower motor assembly, and contains the following: blower motor and blower motor wheel (18504) blower motor resistor (with manual control option) A/C blower motor speed control (19E624) (with electronic control option) A/C air inlet door (19A813) A/C air inlet door actuator motor A/C evaporator core (19860) (if equipped) Blower Motor Resistor If you have EATC, Electronic Automatic Temperature Control for your heater/a/c system, you WON'T have a blower motor resister. Instead, you will have a blower motor speed controller in that location. If you have an electronic digital temp control system with a digital display. If so, you have a blower motor speed controller instead of a resister. The controller is a 3" x 3" box with fins on it for cooling. It is located under the dash by the blower motor, just to the left. It has a white aspirator hose routed over it. 2 screws and one connector. It is fairly expensive so be sure it is the bad part. I have one I salvaged a while ago for a spare just in case someone needed it. The aspirator hose takes air from the resister location and feeds it to the temp sensor that controls blower speed, etc. So, your problem could be the motor, the speed controller, the digital control head, the sensor, wiring etc.


What state is bordered by North Dakota and South Dakota?

The US state of Montana is bordered on the east by both North Dakota and South Dakota while the state of Minnesota is bordered on the west by both North Dakota and South Dakota.


What would cause a thumping sound by the blower motor housing on a 1993 Chevrolet truck the blower motor has been replaced so that didn't fix the noise any suggestions?

Answertry tining the blower motor upActually I had a similar problem a while back and a supid mouse had built a nest in the line and had acorns rattling around inside the line. Just a possibility. It happens when it starts to get cold they seek shelter anywhere.


Why does my blower motor turn on while driving?

To move air, that is what it does.


Are North Dakota and South Dakota the same size?

No. South Dakota is larger with a total of 77,116 square miles while North Dakota has a total of 70,698 square miles.


The blower in my jeep wrangler stopped working while it was on could this be a fuse problem?

It could be a blown fuse but more likely it is either the blower motor resistor or the blower switch itself. TJ's are prone to overheating and melting blower motor switches because of high current flowing through them. To test the switch, check all four fan speeds to determine which of them is inoperable. The blower motor resistor regulates the blower speed on positions 1 through 3. If the blower doesn't work on any position 1 through 3 but it works on full speed (Position 4), the blower motor resistor is bad and needs to be replaced. If the blower doesn't operate at full speed (position 4) the blower motor swithch is bad and you need to replace switch assembly, After that, check the lower fan speeds to make sure they work. If any of them doesn't work, replace the blower motor resistor also.