Manually turning off a shunt trip breaker should not set off the fire alarm. The only way that the breaker could set off the fire alarm when turned to the off position is if there is an auxiliary contact on the breaker connected to the fire alarm circuit. This is not usually done because the breaker should be able to be turned off when doing maintenance on the breakers circuit. If the breaker is a mandatory feed breaker to a piece of fire alarm equipment and shouldn't be left in the off position it might have a trouble circuit connected to the fire alarm panel. A trouble alarm on a fire alarm panel is different from an alarm circuit alarm.

User Avatar

Wiki User

12y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: Will manually turning off a shunt trip breaker set off the fire alarm?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

Can a shunt trip breaker be tripped from to different emergency buttons?

Yes a shunt trip breaker can be activated manually.


What are the functions of shunt trip coil in ACB?

shunt trip coil used to trip the breaker automatically or manually.


What is shunt coil?

A shunt-trip coil is a built-in component of a shunt-trip circuit breaker. It is a magnetic coil that can be energized externally to make the breaker trip to shut off the flow of current. For instance, fire sprinklers are sometimes required in the top of elevator shafts in case of a fire in the shaft. If the sprinklers were to spray water on the electric controls in the elevator cab, people could be hurt or killed, either from electrocution or from the elevator malfunctioning. In these cases, a shunt-trip breaker is installed in the circuit feeding the elevator controls, and the fire alarm system sends a trip signal if it detects waterflow from the sprinkler system. This trips the breaker and removes power from the elevator cab. Once tripped, a shunt-trip breaker requires a person to reset it manually.


Does the power supplied to trip shunt trip breaker have to be applied momentarily or can it latch?

A shunt-trip breaker trips when voltage is applied to the coil. It does not self-reset when the voltage is removed, the breaker must be reset manually. The trip voltage can either latch or be applied momentarily, but must be de-energized before the breaker will reset.


What is a shunt-trip breaker?

It works just like a normal circuit breaker with one additional function. A shunt-trip breaker also has a built-in magnetic coil that can be energized externally to trip the breaker. For instance, fire sprinklers are sometimes required in the top of elevator shafts in case of a fire in the shaft. If the sprinklers were to spray water on the electric controls in the elevator cab, people could be hurt or killed, either from electrocution or from the elevator malfunctioning. In these cases, a shunt-trip breaker is installed in the circuit feeding the elevator controls, and the fire alarm system sends a trip signal if it detects waterflow from the sprinkler system. This trips the breaker and removes power from the elevator cab. Once tripped, shunt-trip breakers require a person to manually reset them.


How do you hook up wire from ansul system to shunt trip breaker?

You would need to take the "input" wire for the shunt trip breaker to an electrical switch (not alarm initiating switch, which are DC voltage rated) within the Automan unit and connect to the "Common" connection and the "return", the wire to the actual shunt circuit of the breaker, from the "Normally Open" connection of the switch. When the unit activates, the switch will be placed into "Closed" position, therefore completing the circuit and activating the shunt coil.


How much does a shunt trip breaker cost?

The cost of a shunt trip breaker depends on the amperage and number of poles the circuit connected to it needs. The cost of the shunt trip over a conventional breaker is substantially more.


How do you connect 480volt and coil to fire alarm system?

I can only assume that you are attempting to connect 480VAC coil from a elevator to a fire system in order to shunt the elevator. In order to do this you will need a shunt trip breaker rated for this use.


How do you detect if a shunt trip breaker is malfunctioning?

The way to detect if a shunt trip breaker is malfunctioning is to manually trip the breaker. The shunt is usually wired through a auxiliary relay. Make sure that before you trip the breaker that the load can be shut off without taking a production line etc. off line. Trip the auxiliary relay using a test jumper to activate the relays coil. The breaker's handle will move to mid throw and the load will disconnect from the supply power. If the breaker trips then it is working properly. If the breaker does not trip trouble shoot the circuitry that is used to trip the breaker. Usual problem is an open circuit.


Where do you connect the two leads of a shunt trip breaker?

Usually the breaker's shunt trip coil is tied to a corresponding current transformer that is sized to the amperage that is allowed to be passed through the breaker. These types of breakers can also be connected into a distribution monitoring device. If the monitor detects a phase reversal or phase loss or voltage rise or drop the breakers shunt trip coil is remotely energized and isolates equipment down stream from the fault. Shunt trip coil circuits are also used as safety circuits where the situation calls for only one breaker to be energized at a time. If the second breaker is inadvertently closed, this would allow both breakers to be on, the second breaker's auxiliary contacts that are an internally part of that breaker will close the safety circuit and energize the shunt trip in the first breaker to causing it to open. So as you can see the two wires could be part of many wiring configurations depending on what situation calls for.


How do you reset a shunt trip breaker?

A shunt trip breaker is reset the same way as an ordinary breaker, move the handle to the full off position and then to the full on position. First check the tripping circuit, sometimes a latch relay is used to hold the breaker shunt trip coil in the trip position. If this is the case then reset the latch relay first.


What voltage feeds the coil on a shunt trip breaker?

220V