No you can not it's 31 amps

User Avatar

Wiki User

14y ago

What else can I help you with?

Related Questions

How much energy does a 75kW motor use?

Multiply 75 kW by T hours of use = 75T kWh, which is how much energy the motor uses.


My breaker says use 75 degree wire can i use 90?

You can use 90 degree celcius rated wire. It just must be derated to the 75 degree column in the book NFPA 70 article 310.16 table. Meaning, if you are running romex wire, you don't have to run larger wire in most situations.


What gauge wire would you use to wire a 120V 20A motor?

For a 120V 20A motor, you would typically use a 12-gauge wire to ensure it can handle the current without overheating. This wire size is suitable for the amperage and voltage to provide proper insulation and safe operation for the motor.


What is the recommended wire size for a 75 amp electrical circuit?

The recommended wire size for a 75 amp electrical circuit is typically 6 AWG (American Wire Gauge) for copper wire.


What size wire for 75 feet of wire for a 30 amp 220 volt oven?

A 30 amp breaker run 75 feet would require you use AWG #10 wire. But, an oven normally pulls more that 30 amps and I would not use #10 wire on a 30 amp breaker for an oven. Normally any newer oven is wired with AWG #6 gauge wire on a 50 amp circuit breaker so the breaker will not trip during heavy use of the oven. Some older ovens could use a #8 wire on a 40 amp breaker.


How much power in a 75 Chrysler boat motor?

75 hp


What size wire for 25 amp 110 volt for 75 feet?

For a 25 amp load at 110 volts over a distance of 75 feet, it is recommended to use a minimum of 10 gauge wire to ensure proper conductivity and safety. Using a wire gauge smaller than 10 may result in voltage drop and overheating of the wire.


Where is the starter motor on a rover 75?

The starter motor is at the rear of the engine.


Where is the starter motor on rover 75?

The starter motor is at the rear of the engine.


What should be the current of siemens 75 kw motor at no load?

starting current of 3 phase 75 KW induction motor


What is the Best MIG Wire to use when welding Cor-Ten Steel?

wire will be 70s-2 and the gas is cver shield #6 wich means 75%=ar,and 25% co2


What is the selection procedure for fuse wire for motor load?

An easy way to do this is to get yourself an "Ugly's" book. Its a small electrical reference guide for circuit protection, (sold at Home Depot & some electrical supply houses). Buss, and other fuse makers usually can supply you with a similar guide.You will also need to find the right size Motor Starter & Overload Heater within the Motor Starter. But to answer your question;To select wire, or fuse/breakers for a Motor Load, you need to look at the Motor's FLA (Full Load Amps), take that number and multiply it by 1.25 (this is a 'rule of thumb' & not Absolutely necessary),-Now you have the maximum amperage that the motor will draw under NORMAL OPERATING CONDITIONS. Go to the NEC section on conductors (i.e. wires) and find a suitable gage wire (in the 75 deg column) and find a wire that will handle the amount of current the your load requires.Now find a fuse or breaker that is permitted for the WIRE, not the load.For example: if you have a motor that draws 10 amps (full load), you might use 16 gage wire, 16 gage wire may be rated for 20A, use a breaker, or fuse rated for 20A.Its always best to use the lowest temperature column in the NEC book because you have to account for all connections in the circuit (i.e. lugs, crimps, spades, terminal blocks, etc.)YOU NEED TO SELECT A FUSE, OR BREAKER BASED ON THE WIRE SIZE, NOT THE LOAD ! !