For an 11kW 3 phase motor, you would typically need a isolator with a current rating of at least 18-20 amps per phase. It's important to also consider the starting current of the motor and select an isolator that can handle the motor's inrush current. Make sure to consult with a qualified electrician to determine the appropriate isolator size for your specific application.

User Avatar

AnswerBot

1y ago

What else can I help you with?

Continue Learning about Natural Sciences

What is the start up amps on a 200 hp 3 phase 480 volt motor?

i have 200 hp motor what i need cable size in 100 feet distance


Minimum breaker size 60 horsepower motor?

A 60 horsepower motor typically requires a minimum breaker size of 100 Amps for normal operation. It is important to consult the motor's specifications or a licensed electrician to ensure the correct breaker size for safe and efficient operation.


What size capacitor is needed to start a 1 hp 14 amp 110V motor?

A single phase motor does not actually require a capacitor. This device is only needed when a split phase motor is utilised. A split phase motor needs a device to regulate the power factor associated with the split phase.


Is there any way to get a 3-phase motored 15hp 120 gal compressor to work on any kind of residential hookup?

If the motor voltage is 240 you can hook 240 to any two motor leads then put a switch and a capasitor in series from one leg to the other motor lead.once motor starts open switch,the motor will be rated at 58% about 8.7 hp.Another way to do this is if you have another 3 phase motor the same size or larger ,hookup 240 to extra motor any two leads hook leads from motor to air comp start contactor.Turn shaft on extra by hand it will srart which will make a third leg "3 phase" I know this is working on a three phase wheel balencer for the last 8 years i don't believe i would want to "hand spin" a motor on a compressor... a bit hazardous! another factor here is the direction of rotation as most compressors are sensitive to this. the starting current on a motor of this size and the service it is in quite large, the best bet would be to find a replacement single phase (220V.) motor (matching rotation, speed and starting torque). one could always use a rotary phase converter, but this is a spendy and involved way to do the job.


What size breaker for a 208 volt single phase motor that pulls 1.4 amps?

208 volts is not a common single phase voltage but you could just size your breaker to the capabilities of the conductor. 208 is normally a phase to phase voltage <<>> Many 230 volt motors can be connected to lower voltage supplies. These motors can be connected to supplies of 208 and 200 volts. The code requirement is that the 230 volt full load amperage of the motor be increased by 10% and 15% respectively for wire sizing and breaker selection. To answer the question you will need a two pole 15 amp breaker.

Related Questions

What size fuse required for 11kw motor star delta starting?

This depends on the motor rating.


What is the cable size for 1.5KW 3 phase induction motor?

Sir, what is the cable size for 1.5kw 3phase induction motor 400v?


Can you replace a three phase motor 3 Hp RPM 1420 with a single phase motor for a planer?

Probably not. The single phase three horse power motor will be much larger in physical size than its three phase counterpart, and will probably not fit.


Can you run 22 kw 600v 3 phase induction motor?

Yes this size motor can be operated by bringing a 600 volt three phase supply to it.


What is the cable size for 600V 3 phase ac motor?

you need the current of motor or the KW/HP rating


What size motor do you need to run a compressor 2 stage 80 gallon tank i have a 3 phase on it and want to change motor?

You probably need a 5hp or 7hp motor. Look for HP rating o the 3 phase motor and select the same for single phase. 3 phase has same power but is more efficient at electricity use. Also consider a 3 phase converter. It allows a 3 phase motor to run on single phase service.


Can a 380volt's 3 phase motor can be converted to 230volt's three phase motor?

Only if you want to damage it. "277" Volt 3-phase will usually mean 277 from each phase to neutral, and 480 from phase to phase. By "230 3-phase", you likely mean 120 phase-to-neutral, and 208 phase-to-phase. If you really mean 230, then you are probably NOT talking about a three phase motor.


By how many amps may a three phase motor exceed its data plate rating?

On a normal three phase motor on the nameplate there is a value in the S.F. box. This is the service factor. Depending on the size of the motor this value will vary. Smaller size motors usually have a service factor of 1.15.See related links below.


What is the start up amps on a 200 hp 3 phase 480 volt motor?

i have 200 hp motor what i need cable size in 100 feet distance


Minimum breaker size 60 horsepower motor?

A 60 horsepower motor typically requires a minimum breaker size of 100 Amps for normal operation. It is important to consult the motor's specifications or a licensed electrician to ensure the correct breaker size for safe and efficient operation.


What is the cable size for a 168 kilowatt 3 phase motor?

First of all find out what voltage the motor is designed to work on.


What would it cost to run a 3 phase induction motor?

Depends on the size. You can go from a few hp to many thousands of hp.