What determines the power rating of a machine?

generally rating means the condition when the machine can give maximum efficiency without being overheated .In transformers and generators it is decided by core as well as copper loss(flux proportional to supply voltage,current proportional to copper loss).so both are rated in kVA whereas motors are rated as maximum output they can deliver i.e kW.

How do you determine the internal resistance of capacitors?

The best way is to check the data sheet and see if ESR (equivalent series resistance) is listed.

How do you convert power reading in kWh to kva?

These are two different values. kWh is the amount of kW that are used in an hour. To convert kW to kva use the same formula but leave out the pf (power factor) component.

Answer

First of all your should realise that power is measured in watts (or kilowatts), not in kilowatt hours! A kilowatt hour is an unit of measurement for energy, or work done, NOT power! So your question doesn't actually make any sense!

Furthermore, a kilovolt ampere is the unit of measurement for apparent power, and it should be written as 'kV.A', not 'kva'.

So you cannot convert energy in kilowatt hours to apparent power in kilovolt amperes, as we are talking about two completely different quantities! It's like asking "How do you convert miles into kilometres per hour?" That's what I mean by your question not making any sense!

The first answer needs correction, as the kilowatt hour is not 'the amount of kilowatts used in one hour'. You do not 'use' kilowatts, as kilowatts is simply a rate. So the correct definition is that a kilowatt hour is the amount of energy used in one hour, at the rate of one kilowatt.

Do power saver really works?

No, it is not.These devices don't decrease your bill.It is basically about making compensation of reactive power with capacitors.So in your houses it isn't necessary to do that.Because your electric power meter does not count reactive power.

Why digital energy meter show negative reading?

Negative Power Values

I am seeing all negative values from the WattNode meter I just installed. Does that mean the CTs are installed backwards?

Causes

There are a few different reasons for negative power readings:

  • One or more CTs are installed backwards. CTs have a label or arrow that should point towards the source of power (generally the transformer, breaker, or fuse).
  • The white and black CT wires are swapped at the WattNode.
  • This is a bidirectional power measurement application, such as a photovoltaic system, where negative power occurs whenever you generate more power than you consume. In this case, there is nothing wrong with the negative power readings, so long as they occur when power is being generated.
  • The current transformers are installed so that the phases don't match the voltage phases. For example, suppose the CTs are shifted by one phase, so that instead of monitoring phases A, B, and C (in that order), the CTs are on B, C, and A. This will generally result in negative power or a very low power factor.
  • In some cases, you may see negative power readings from a PV inverter at night. See Non-Zero Nighttime PV Power Generation for more information.
Fixes
  • If the CTs are installed backwards or the white and black wires are reversed:
    • Reverse the CT on the wire being monitored.
    • Swap the white and black wires at the WattNode. Note: Our CTs only generate 333 mVAC at full-scale, so they are safe to rewire while the load is active (older 5A output CTs pose a shock hazard if disconnected with a live load).
    • For WattNode Modbus models, the CtDirections (1607) register can be used to reverse the polarity of any of the CTs. Note:this cannot be used to correct for situations where CT phases do not match the voltage phases, such as swapping phases A and B on the current transformer inputs. 0 - All CTs normal 1 - Flip phase A CT 2 - Flip phase B CT 4 - Flip phase C CT 3- Flip phase A CT and flip phase B CT 5 - Flip phase A CT and flip phase C CT 6 - Flip phase B CT and flip phase C CT 7 - Flip all CTs (A, B, and C)
  • If the CTs are installed with phase mismatches:
    • Try to visually identify and correct the mismatches. It may help to label each CT and its wires as "Phase A", "Phase B", and "Phase C".
    • If it isn't possible to visually identify the correct phases, there are two other options:
      1. Trial and error: Start with the phase A CT inputs. Try connecting each pair of CT wires in turn until you get a positive reading with a power factor near the expected value for your load (be sure to do this when the load is active). Repeat this for the other two phases. The process is more complex if the CTs might be installed backwards, because then you also need to try connecting each CT twice (once with the white-black wires reversed) to try to get a positive power reading. We recommend against this trial and error approach, because there are configurations that may result in plausible readings, but are completely incorrect. For example, if you reverse the white-black wires on all three CTs and shift all three CTs by one phase, you will generally get positive power readings with a good power factor, but the measured power may be off by 10-40%. If you must use trial and error, you should try to confirm the final results with a handheld power analyzer.
      2. Measure the real and reactive power for each phase (make sure the load is active if you are monitoring something like a chiller, blower, compressor, etc.). Try to estimate the expected power factor of your load or at least determine the type of load (motor, office equipment, lighting, etc.). Then contact Continental Control Systems support for help identifying the wiring problem. There are some situations that are ambiguous, so it may not always be possible to diagnose remotely.
Prevention
  1. Before installing the CTs, label each CT at the CT and at the end of the white-black wires with "Phase A", "Phase B", "Phase C" or with color coded tape. If you are installing multiple sets of CTs, also label them for the load you are monitoring.
  2. Be sure to install the CT with the arrow or label facing towards the source of power, generally the circuit breaker, fuse, or transformer.
  3. Use colored wires for the line VAC connections to the WattNode to keep the phases correctly identified.
  4. When wiring to the WattNode, be careful to match the white wire to the white dot on the label and the black wire to the black dot on the label.
  5. Do NOT assume that all three-phase breakers will have the same phase ordering. For example, in our panel, the three-phase breakers near the top are ordered A-B-C, but then there are two single-phase breakers and another three-phase breaker with the sequence C-A-B. Also, the phase sequence may be different on the right and left sides of the panel. Verify the phases visually or with a voltmeter.
Retrieved from "http://www.ccontrolsys.com/w/Negative_Power_Values"

Category: WattNode "-" means power is being exported instead of import in case of a import/export dual porpose meter

The capacitive reactance of a capacitor increase as?

The capacitive reactance of a capacitor increases as the frequency decreases.

What is the value of power factor for a pure inductor?

Angle between v and i is 90 deg

so, cos 90 = 0

Same for pure capacitor

Will a fuse work successfully connected in parallel?

Absolutely not. A fuse works by "monitoring" the current flowing in the circuit. Setting the fuse next to whatever it should be monitoring will do absolutely no good.

What is use of sink and source in variable frequency drive?

The inverter is mainly composed of rectifier, filter, inverter, brake unit, drive unit, detection unit and microprocessor unit. The inverter relies on the opening and closing of the internal IGBT to adjust the voltage and frequency of the output power supply, providing the power supply voltage required by the motor according to its actual needs, thus achieving the purpose of energy saving and speed regulation. If you want to buy an inverter, you can go to the KUVO website, which is popular for its high quality.

What is the Function of inter poles in a DC machine is?

take care of the problem of induced AC field current due to armature reaction

/Omara

If you doubled the load resistor in a wheatstone bridge. the load current would not be half as much Why not?

Because by increasing the load resistance, the total circuit resistance is reduced. This means with less resistance, there is more current drawn from the source. Doubling the size of a load resistor increases the load current.

RMS of non sinusoidal?

Vrms=sqrt[1/T * integral(v^2(t)dt, 0,t]

Irms=sqrt[1/T * integral(i^2(t)dt, 0,t]

Do boy have better gross motor or fine motor skills?

As children develop through early childhood boys have much better gross motor skills than girls, and vice versa. Boys are better at play involving throwing balls and physical rough housing, while girls are better at play involving using small objects (such as doll houses) and painting. They also gravitate toward these different types of play as they continue to develop through early childhood, further refining their skills.

What is a 'sandwich course' in engineering?

A sandwich course combines classroom learning and practical work placements in separate blocks.

Why cannot test phase to phase on 3 phase motor?

Motor voltages and amperages can both be tested. The best way to test the continuity of a motor is with a megger. This will check that the motor windings are intact and if there is any voltage leakage to ground or voltage leakage to one of the other two windings in the motor. To check amperages on the motor it will have to be energized. Leave a message in discussion page as to what you are trying to do.

<<>>

Because there is no such thing as 'phase to phase'! However, there is such a thing as 'line to line', and this can be tested!

The points where circuits interconnect with other circuits is known as what?

The point where wires interconnect with other wires is known as a "junction".

In your panel the circuit breakers are connected to the buss, each circuit breaker feeds a different circuit. Different circuits are not connected together.