It is a method of starting a three phase motor at a lower than operating voltage. The motor is operated at that voltage for a short specific time and then the controls switch to the motors full run operating voltage.

User Avatar

Wiki User

12y ago

What else can I help you with?

Related Questions

What is wye-delta motor control?

It is a type of starter that allows a motor to be started across the line by starting the motor with a reduced inrush current. The motor is started in a wye configuration until it gets up to speed and then a timer drops the wye contactor out a draws the delta configured contactor in. The motor then operates in a delta wired configuration.


How can you terminate a 3 wire wye motor to a 3 phase delta connection?

To terminate a 3 wire wye motor to a 3 phase delta connection you need a 3 phase transformer to convert from delta to wye. Do not lift the common neutral connections inside the motor and rewire for delta, because the voltages will be wrong.


Why is it the control of a three phase motor trips when changing from wye configuration to delta?

Few things to look for, one, are the contacts good on the run contactors. Two, has the motor wiring been changed in any way, contactors or leads on motor. Trace wiring and make sure the leads are paired correctly to the starters. Three, make sure the start timer is not bringing the run contactors in too late. Also check that the shorting contactor is opening when the run contactor comes in.


Is a three phase high leg delta better than a wye for a motor?

There is really no advantage, the only purpose of having the variety is for motor manufacturer companies to be able to sell their product to customers if the building's electrical service is of a Delta of Wye configuration.


What size of electric motor that requires wye delta starter?

10 hp and above motor power rating....


Should a star-delta motor be supplied wye or delta power?

A star-delta motor should be supplied star-delta.Wye is simply another name for star. Star-delta motors use a star or wye configuration to start, and a delta configuration to run. This reduces the voltage on the windings during the high current starting time.


What is the reason motor runs delta connection?

Motor run delta connection because in delta connection it is less ampere needed and it sometimes it change the wye connection because of the available suply


How much voltage does star-Delta starter give to motor at start?

A delta starter supplies what ever the supplied voltage to the line side of the contactor is. The inrush current is usually 300% of the full load amperage of the motor. Edit to above answer: Actually the question is for a Wye-Delta Starter (Wye=Star). There are two contactors, one in Wye configuration and one with Delta. The Wye is used to start and the Delta for run. This is a reduced voltage start scheme. Though the line supply voltage remains the same, for instance 480VAC, the phase voltage at the motor will be different for the Wye: V(phase) = V(line)/1.732 In a Delta V(phase) = V(line) So the Phase Voltage during the start will be 277VAC and then when the motor is spinning, usually after a set time delay, the Wye contactor drops out and the Delta contactor kicks in so that Phase Voltage is now the full 480VAC.


What are the materials used at wye delta motor control?

Wye-delta motor control systems primarily use electrical components such as contactors, overload relays, and control relays. The wiring is typically made from copper or aluminum conductors to ensure efficient current transmission. Additionally, insulation materials like PVC or rubber are used to protect the wiring and components from environmental factors. Other materials may include circuit breakers and fuses for safety and protection against overloads.


How do you determine a wye delta timer is good?

A wye delta timer is used to change the wye connection to the delta connection. The timer should have enough of a setting to allow the wye motor speed to get up to full RPM on that winding. It then times out and changes to the delta run winding. Check the voltage on the "hot" terminal of the timer to make sure that you have control voltage to that point. If the delta magnetic does not pull in check for voltage on the mags coil. If the voltage is present, then the mags coil is under suspicion. Do a continuity test on the coil. When the timer times out the control voltage should appear on the other side of the timers contact. If the timer has a "C form" contact make sure that the coil wire in on the correct screw. The "hot" control wire to common terminal and coil wire to the N.O. terminal.


Power a 415volt motor with 480volts?

in low voltage connection in wye (star conncetion) 415v high voltage connection in delta 480v


What connection is the higher ampere between delta and wye?

For the same load, delta provides higher current than wye, or star.Wye voltage is 1 / 1.732, or 0.577 that of delta. (1.732 is the square root of 3.) This gives a power of 0.333 for wye, as opposed to delta. (0.5772 = 0.333)This is why (no pun intended) we use wye-delta starters on large motors - it allows them to come up to speed at 1/3 power, before switching to full power on delta.